mobile diesel power generation set
USD $7,350 - $15,000 /Set
Min.Order:1 Set
Shandong Huali Electromechanical Co., Ltd.
50KW/62.5KVA mobile diesel power generation set
Specification of genset
Genset model:HL50GF
Prime power: 50KW / 62.5KVA
Standby power: 55KW / 68.75KVA
Power factor: 0.8
Rated Voltage: 400/230V
Rated frequency (HZ): 50
Specification of diesel engine
Engine Model: 4BTA3.9-G2
Manufacturer: DCEC
Governor: E
Air intake way: Naturally aspirated
Cylinders/Arrangement: 4/L
Bore× Stroke(MM): 102×120
Fuel Consumption Rate(L/h): 13.1
Lubricating oil capacity(L): 10.9
Coolant capacity (L): 18.4
Compression ratio: 16.5:1
Displacement, total (L): 3.9
Net weight (kg): 386
Engine speed (rpm): 1500
Max Power (kW): 55
Starting Method: DC12V electrical starting
Specification of alternator
Alternator model: HLF50
Connecting Type: 3 Phase and 4 Wires
Number of Bearing: 1
Protection Grade: IP21
Altitude: ≤1000m
Exciter Type: Brushless, Self-exciting, AVR automatic voltage regulating,100% Copper winding wire
Insulation Class: H
Telephone Influence Factor (TIF):≤50
Voltage Regulation, Steady State: ≤±1%
Transient State Voltage: ≤-15%~+20%
Control System
Operating temperature: -20°C~60°C
Relative Humidity: 95%
Operating voltage: DC24V (range: 18-30V, pressure: 50V/5 mm )
Standard functions: Engine Control/Generator Monitoring/Generator Protection/
Engine Monitoring/Clear Text Display
Shutdown: Loss of Speed Signal,Alternator Under / Over Voltage,Alternator Under/ Over Frequency,
Mains Under / Over Voltage,Mains Under/ Over Frequency,Under / Over Speed,Low Oil Pressure,High Engine Temperature,Phase Sequence Electrical (Option),Earth Fault (Option)
Warning: Alternator Under / Over Voltage,Alternator Under/ Over Frequency,Mains Under / Over Voltage,Mains Under/ Over Frequency,Under / Over Speed,Low Oil Pressure Pre-Alarm,High Engine Temperature Pre-Alarm,High/Low Battery Voltage,Over-current,Periodic maintenance