pvc insulated electric copper wire
USD $0.1 - $1 /Kilometer
Min.Order:1 Kilometer
pvc insulated electric copper wire
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.
Type | Name | Laying place and requirement | Long term working Temperature 0C |
60227IEC01 05 BV BLV | Copper conductor PVC insulated wires Aluminum conductor PVC insulated wires | Fixed laid indoors Conduit etc. |
70 |
60227IEC07 (BV-90) | Heat resistant copper conductor PVC insulated wire at 90 0C | Mainly be laid at the places of high temperature environment and can be laid indoors ,conduits. |
90 |
BVR | Copper conductor PVC insulated flexible cable | Be for laying permanent place where flexible required. |
70 |
60227IEC10 (BVV) BVV | Copper conductor PVC insulated PVC sheathed round wires | Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground. |
70 |
BLVV | Aluminum conductor PVC insulated PVC sheathed round wires | ||
BVVB | Copper conductor PVC insulated PVC sheathed flat wires | ||
BLVVB | Aluminum conductor PVC insulated PVC sheathed flat wires | ||
60227IEC02(RV) 60227IEC06(RV) | Copper conductor PVC insulated flexible connector wire | Mainly used at middle and light style moving electronics, home appliances, power and lighting and the places where flexible required |
70 |
60227IEC42(RVB) | Copper conductor PVC insulated flat flexible connector wire | ||
RVS
| Copper conductor PVC insulated flexible twisting connector wire | ||
60227IEC52(RVV) 60227IEC53 | Copper conductor PVC insulated PVC sheathed round flexible connector wire | ||
60227IEC08 (RV-90)
| Cu conductor heat resistant PVC insulated flexible connector wire at 90 0C | Mainly used at the places where heat resistance is required |
90 |
Sincerely looking forward to your attention, more specification details about this type or others please contact me freely; maybe I’ll give you a big surprise.