P10 outdoor full color digital outdoor advertising column LED screen display
USD $549 - $839 /Square Meter
Min.Order:1 Square Meter
Jiangsu JD Electronics Co., Ltd.
P10 Full Color - Outdoor | Pixel Composition | red blue green |
Pixel (mm) | 10 | |
Density(dots/m2) | 10000 | |
Brightness(Nits) | ≥6000 | |
Resolution of Module(dots) | 256 | |
View Angle | H:110°,V:60° | |
Module Number Per Square Meter(p/m2) | 30.06 | |
Control Mode | Synchronous/Asynchronous | |
Why you choose us ? | Drive Mode | 1/4 |
1.Certifications of CE,CCC,ULand ISO9001 | Refresh Rate(HZ) | ≥180 |
2.Attractive factory price and high quality | Working Temperature(°C) | -25-- +85°C(for working) |
3.Professional factory and sales team | Working Humidity | 10%-95%RH |
4.Efficient and timely communication | Model Size(mm) | 160*160 |
5.Company audited by BV | Cabinet Material | Steel/Aluminum |
6. Good after sales service | Lifespan | 100,000 hours |
7. Two year's warranty | Maximum Power | 860W/m2 |
Guarantee | 2 years |
Accessory List | |||
name | module | ||
control card | BX-5A | ||
BX-5M | |||
BX-5U | |||
BX-5E | |||
BX-5QS | |||
BX5K/5MK | |||
WIFI | support wifi connection | ||
RF | |||
power supply | economical | 300W/350W/500W | |
100W/150W/200W | |||
standard | 200W/300W | ||
200W320W PFC | |||
Ultrathin&Efficient power supply | |||
Switched LED Power Supply | |||
| Cabinet | outdoor standard | |
outdoor simple | |||
outdoor aluminium rental cabinet | |||
outdoor general hoisting | |||
court advertising cabinet | |||
single-sided opening cabinet | |||
two-sided opening cabinet | |||
Aluminum frame | Kinds of colors and specificationals according to your request | ||
LED signal cable | Used to connect the signal between every module | ||
LED power line | Transfer current |
To assure the LED goods intact,we use shockproof packages and move cautiously.
Jiangsu JD Electronics Co., Ltd. was founded in June 2002 of which headquarter is located in Yizheng High-tech Development Zone of Yangzhou.It includes manufacturing center – Jiangsu JD Electronics, marketing center – Yangzhou JD Electronics, R&D center – Nanjing JD Electronics.
JD specialized in LED display and LED lighting. From manufacturing, R&D to engineering installation, we provide one-stop service. At present,annual production of LED display module amounts to 300 thousand and LED lighting module amounts 1 million pieces. We are members of Display Branch of China Photoelectricity Institution and Nanjing Lighting Institution.Our products have obtained silver medal of Chinese Famous Brand Exposition, Jiangsu Province Famous Brand Product and Yangzhou Famous Brand.And our company has passed ISO9001-2008 quality system certificate; products have passed CCC, CE, RoHS, UC certificate.
JD has won wide trust and good repute due to its stable quality, reasonable price and professional service. In the path of development, we have realized that it is important to regard customer as the center. We will as always carry on the spirit of enterprise- dedication, teamwork, innovation.
Welcome to JD Electronics!
Usage Considerations of LED Display
1.Switching sequence
1) screen switching sequence:
on: first turn on the computer, then screen
off: first shut off screen, then computer.
2) Interval of switching LED display must be greater than 1 minute.
2. Ambient temperature
When ambient temperature is too high or cooling condition is bad, users had better not to turn on the screen for a long time.
Screen shall be installed in temperature from-10 °C to 40 °C.Over environment temperature range, temperature control equipment must be installed.
It is forbidden to install LED display near any heat source.
3.Ambient humidity
When installing screen, ambient relative humidity should be in the range from 30% to 70%.It is prone to get static electricity when the indoor humidity is below 30%;
when the indoor humidity is higher than 70%, electronic components are easy to get damp.
4.Corrosive gas environment
Please do not install the display in corrosive gas environment containing acid or base components, such as chemical warehouse.
5. Electromagnetic radiation environment
Please do not install display when electromagnetic radiation and radio frequency radiation environment is over field strength 5V/m.
If necessary, isolation treatment should be taken.
6.Steady power supply
If necessary, users have to install surge switches in the distribution box and ground fault protection to avoid lightning strikes.
Do not use the display in strong lightning and other severe weather.
7. Conductive material is strictly prohibited to contact display, such as metal dust and water.
Screens are placed in the environment of low dust as far as possible, otherwise it will affect the display effects, as well as damage the circuit.
If exposed to water for various reasons, please immediately power down until the screen unit dry.
8.Controlling colors
Do not display a long time in a white, red, green, blue or other bright screen, because this will affect the display lifetime.
9.Controlling time
LED display at least rest 2 hours a day. Normally turn on the screen at least twice a week or more (Especially in the rainy season it is necessary to turn on the display every day).
And it maintains more than 2 hours every time.
10.Regular overhaul
LED display requires regular inspection to check circuit damage. If it does not work, change it in time. If circuit damages, it should be repaired or replaced.
11.Security alerts
Users must ensure safety while installing Led display. The factory only offers products and reference programs of frame fixation.
Users can ask relevant authorities to confirm according to local conditions and field conditions.