Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)
USD $450 - $500 /Set
Min.Order:1 Set
Shanghai Bante Instruments Limited
Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter
Multiparameter benchtop pH conductivity meter includes 12 optional parameters, the meter is
suitable for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of the liquids.
Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter - Features:
pH Mode:
• High accuracy benchtop pH conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.
Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion
factors, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 12 parameters, including the calibration points, resolutions,
stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter - Specifications:
pH:
• Range: -2.000~20.000pH
• Accuracy: ±0.002pH
• Resolution: 0.1, 0.01, 0.001pH
• Calibration Points: 1 to 5 points, USA, NIST, DIN Standards
• Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
mV:
• Range: -1999.9~1999.9mV
• Accuracy: ±0.2mV
• Resolution: 0.1, 1mV
• Calibration Points: 1 point (Only for Relative mV mode)
• Calibration Range: ±200mV
Conductivity:
• Range: 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
• Accuracy: ±0.5% F.S
• Calibration Points: 1 to 5 points
• Calibration Solutions: 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
• Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
• Temperature Coefficient: 0.0~10.0%/°C
• Compensation Modes: Linear or Pure Water
• Cell Constant: K=0.1, 1, 10
• Normalization Temperature: 20 or 25°C
TDS:
• Range: 0~10ppt (Max. 20ppt, depending on factor setting)
• Accuracy: ±1% F.S
• TDS Factor: 0.1~1.0 (Default 0.5)
Salinity:
• Range: 0~10ppt (Max. 80ppt)
• Accuracy: ±1% F.S
• Measurement Modes: Seawater or Practical Salinity
Resistivity:
• Range: 0~100MΩ
• Accuracy: ±1% F.S
• Resolution: 0.01, 0.1, 1
Temperature:
• Range: 0~105°C, 32~221°F
• Accuracy: ±0.5°C, ±0.9°F
• Resolution: 0.1°C
• Calibration Points: 1 point
• Calibration Range: Measured value ±10°C
Others:
• Hold Function: Manual or Automatic
• Stability Conditions: Low or High
• Calibration Due: 0 to 31 days
• Power Off: Manual or Automatic (10, 20, 30 minutes)
• Memory: Stores up to 500 data sets
• Output: USB Communication Interface
• Power Requirements: DC5V, using AC adapters, 220VAC/50Hz
• Dimensions: 210(L)×188(W)×60(H)mm
• Weight: 1.5Kg
Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter - Accessories:
• pH Electrode
• Conductivity Electrode
• Temperature Probe
• pH Buffer Solutions (pH4.01/7.00/10.01)
• Calibration Solutions (84µS/cm, 1413µS/cm, 12.88mS/cm)
• USB Cable
• DC5V Power Adapters
Bante Instruments - Professional manufacturer for Benchtop pH/Conductivity/TDS/Salinity Meter