Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

USD $450 - $500 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Shanghai

Quick Details View All >

Place of Origin:
Shanghai, China
Brand Name:
Bante Instruments
Model Number:
Bante902

Shanghai Bante Instruments Limited

Business Type: Manufacturer
Shanghai China
Main Products: PH Meter ,Lon Meter ,Conductivity Meter ,TDS Meter ,Salinity Meter ,Dissolved Oxygen Meter ,Magnetic Stirrer ,Electrode

Product Details

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter
Multiparameter benchtop pH conductivity meter includes 12 optional parameters, the meter is
suitable for measuring the pH, ORP, Conductivity, TDS, Salinity and Resistivity of the liquids.

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter - Features:
pH Mode:
• High accuracy benchtop pH conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion
  factors, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 12 parameters, including the calibration points, resolutions,
  stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter - Specifications:
pH:
• Range: -2.000~20.000pH
• Accuracy: ±0.002pH
• Resolution: 0.1, 0.01, 0.001pH
• Calibration Points: 1 to 5 points, USA, NIST, DIN Standards
• Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic

mV:
• Range: -1999.9~1999.9mV
• Accuracy: ±0.2mV
• Resolution: 0.1, 1mV
• Calibration Points: 1 point (Only for Relative mV mode)
• Calibration Range: ±200mV

Conductivity:
• Range: 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
• Accuracy: ±0.5% F.S
• Calibration Points: 1 to 5 points
• Calibration Solutions: 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
• Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
• Temperature Coefficient: 0.0~10.0%/°C
• Compensation Modes: Linear or Pure Water
• Cell Constant: K=0.1, 1, 10
• Normalization Temperature: 20 or 25°C

TDS:
• Range: 0~10ppt (Max. 20ppt, depending on factor setting)
• Accuracy: ±1% F.S
• TDS Factor: 0.1~1.0 (Default 0.5)

Salinity:
• Range: 0~10ppt (Max. 80ppt)
• Accuracy: ±1% F.S
• Measurement Modes: Seawater or Practical Salinity

Resistivity:
• Range: 0~100MΩ
• Accuracy: ±1% F.S
• Resolution: 0.01, 0.1, 1

Temperature:
• Range: 0~105°C, 32~221°F
• Accuracy: ±0.5°C, ±0.9°F
• Resolution: 0.1°C
• Calibration Points: 1 point
• Calibration Range: Measured value ±10°C

Others:
• Hold Function: Manual or Automatic
• Stability Conditions: Low or High
• Calibration Due: 0 to 31 days
• Power Off: Manual or Automatic (10, 20, 30 minutes)
• Memory: Stores up to 500 data sets
• Output: USB Communication Interface
• Power Requirements: DC5V, using AC adapters, 220VAC/50Hz
• Dimensions: 210(L)×188(W)×60(H)mm
• Weight: 1.5Kg

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter - Accessories:
• pH Electrode
• Conductivity Electrode
• Temperature Probe
• pH Buffer Solutions (pH4.01/7.00/10.01)
• Calibration Solutions (84µS/cm, 1413µS/cm, 12.88mS/cm)
• USB Cable
• DC5V Power Adapters


Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter (CE Certificate)
Bante Instruments - Professional manufacturer for Benchtop pH/Conductivity/TDS/Salinity Meter

Contact Supplier

Mr. BOB CHEN General Manager Chat Now
Telephone
86-21-54248715
Fax
86-21-64164119
Address
Rm.1606, No.2, Lane 777, Zhongshan Rd.(S-2), Shanghai Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > PH Meters
Categories
Hi~