Bante980 Laboratory Dissolved Oxygen Meter | Professional Dissolved Oxygen Meter
USD $320 - $350 /Set
Min.Order:1 Set
Shanghai Bante Instruments Limited
Bante980 Laboratory Dissolved Oxygen Meter
High accuracy laboratory dissolved oxygen meter, 1 or 2 points calibration, manual salinity and
barometric pressure correction. The meter contains 9 optional parameters. Accuracy: 0.2mg/L.
Bante980 Laboratory Dissolved Oxygen Meter - Features:
• High accuracy laboratory dissolved oxygen meter is equipped with a large backlit LCD display.
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.
• Automatic Temperature Compensation ensures accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration improves the measurement accuracy of meter.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 9 parameters, including the calibration points, resolutions,
stability conditions, temperature units, concentration units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
Bante980 Laboratory Dissolved Oxygen Meter - Specifications:
Dissolved Oxygen:
• Range: 0.00~20.00mg/L (or ppm)
• Accuracy: ±0.2mg/L
• Resolution: 0.01mg/L
% Saturation of Oxygen:
• Range: 0.0~200.0%
• Accuracy: ±2.0%
• Resolution: 0.1%
Others:
• Calibration Points: 1 or 2 points
• Temperature Compensation: 0~50°C, 32~122°F
• Barometric Pressure Correction: 60.0~112.5kPa, 450~850mmHg
• Salinity Correction: 0~50g/L
• Stability Conditions: Low or High
• Calibration Due: 0 to 31 days
• Power Off: Manual or Automatic (10, 20, 30 minutes)
• Reset Function: Yes
• Memory: Stores up to 500 data sets
• Output: USB Communication Interface
• Power Requirements: DC5V, using AC adapters, 220VAC/50Hz
• Dimensions: 210(L)×188(W)×60(H)mm
• Weight: 1.5kg
Bante980 Laboratory Dissolved Oxygen Meter - Accessories:
• DO100 Dissolved Oxygen Probe (Made in US)
• DO Filling Solution
• DO Cap Membrane
• DC5V Power Adapters
Bante Instruments - Professional Manufacturer for Laboratory Dissolved Oxygen Meter