Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter
USD $600 - $650 /Set
Min.Order:1 Set
Shanghai Bante Instruments Limited
Bante904P Portable Conductivity/Dissolved Oxygen Meter | Portable Conductivity/DO Meter
Bante903P Portable pH/Dissolved Oxygen Meter | Portable pH/DO Meter
Bante810 Benchtop Dissolved Oxygen Meter | Economical Dissolved Oxygen Meter
Bante980 Laboratory Dissolved Oxygen Meter | Professional Dissolved Oxygen Meter
Bante903 Laboratory pH/Dissolved Oxygen Meter | Digital Dissolved Oxygen Meter
Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter
High accuracy portable multiparameter meter includes 8 measurement modes, the meter is suitable
for measuring the pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved
Oxygen of the liquids.
Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter - Features:
pH Mode:
• High accuracy portable multiparameter meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.
Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units including the ppm, mg/L and mol/L.
Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion
factors, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the calibration points, resolutions,
stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use
the meter smoothly.
Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter - Specifications:
pH:
• Range: -2.000~20.000pH
• Accuracy: ±0.002pH
• Resolution: 0.1, 0.01, 0.001pH
• Calibration Points: 1 to 5 points, USA, NIST, DIN Standards
• Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
mV:
• Range: -1999.9~1999.9mV
• Accuracy: ±0.2mV
• Resolution: 0.1, 1mV
• Calibration Points: 1 point (Only for Relative mV mode)
• Calibration Range: ±200mV
Ion:
• Range: 0.001~19999ppm, mg/L, mol/L (Depending on range of ISE)
• Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
• Resolution: 0.001, 0.01, 0.1, 1
• Calibration Points: 2 to 5 points
• Calibration Solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
Conductivity:
• Range: 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
• Accuracy: ±0.5% F.S
• Calibration Points: 1 to 5 points
• Calibration Solutions: 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
• Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic
• Temperature Coefficient: 0.0~10.0%/°C
• Compensation Modes: Linear or Pure Water
• Cell Constant: K=0.1, 1, 10
• Normalization Temperature: 20 or 25°C
TDS:
• Range: 0~10ppt (Max. 20ppt, depending on factor setting)
• Accuracy: ±1% F.S
• TDS Factor: 0.1~1.0 (Default 0.5)
Salinity:
• Range: 0~10ppt (Max. 80ppt)
• Accuracy: ±1% F.S
• Measurement Modes: Seawater or Practical Salinity
Resistivity:
• Range: 0~100MΩ
• Accuracy: ±1% F.S
• Resolution: 0.01, 0.1, 1
Dissolved Oxygen:
• Range: 0.00~20.00mg/L (or ppm)
• Accuracy: ±0.2mg/L
• Resolution: 0.01mg/L
• Calibration Points: 1 or 2 points
• Temperature Compensation: 0~50°C, 32~122°F
• Pressure Correction: 60.0~112.5kPa, 450~850mmHg
• Salinity Correction: 0~50g/L
% Saturation of Oxygen:
• Range: 0.0~200.0%
• Accuracy: ±2.0%
• Resolution: 0.1%
Temperature:
• Range: 0~105°C, 32~221°F
• Accuracy: ±0.5°C, ±0.9°F
• Resolution: 0.1°C
• Calibration Points: 1 point
• Calibration Range: Measured value ±10°C
Others:
• Hold Function: Manual or Automatic
• Stability Conditions: Low or High
• Calibration Due: 0 to 31 days
• Power Off: Manual or Automatic (10, 20, 30 minutes)
• Reset Function: Yes
• Memory: Stores up to 500 data sets
• Output: USB Communication Interface
• Power Requirements: 3×1.5V "AA" Batteries
• Dimensions: 170(L)×85(W)×30(H)mm
• Weight: 300g
Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter - Accessories:
• pH Electrode
• Conductivity Electrode
• Dissolved Oxygen Probe
• Temperature Probe
• pH Buffer Solutions (pH4.01, 7.00, 10.01)
• Calibration Solutions (84µS/cm, 1413µS/cm, 12.88mS/cm)
• DO Filling Solution
• DO Cap Membrane
• AA Batteries
• Carrying Case
Bante Instruments - Professional Manufacturer for Portable pH/Conductivity/Dissolved Oxygen Meter