Indoor&outdoor cable
Negotiable /Meter
Min.Order:10000 Meters
Zhangjiagang City Dongdu Electronic Cable Co., Ltd.
AWG gauge | Type | Type of Insulation | Number of Threads | Diameter of the Thread | Thickness Insulation | External diameter | I weigh Total Kg/Km | |
| 2 x 20 | acometida | PE | 1 | 0.81 | 1.2 | 3.21 X 7.22 | 24.970 |
Resistant: Moisture, Acid Rain.
Description: soft electrolytic copper wire, insulated with PVC 60. We have 2 types of telephone cables: Interior and surrounded.
Construction: PVC insulated wire 60.
Application: Interior Telephone: internal networks for connecting telephone equipment in offices, factories and residences. Surrounded phone: On connections on the principal distributor of a telephone exchange, dealers intermediate connections, connections in distribution cabinets, internal connection of telephone equipment and installation of bells.
Packing: Interior Telephone: Rolls of 200 meters. Surrounded phone: Rolls of 300 meters.
Color: Interior Telephone: Color White. Surrounded phone: yellow with black.
Test Results Of | ||
Parameters | Minimum Requirement | Test Equipment used |
1.Conductor |
|
|
Diameter (mm) | 1.02 + 0.03 / -0.06 | Micrometer |
% elongation | 1.5 (min) | Shimadzu |
Barding strength | 760 (min) | Shimadzu |
2.Insulation |
|
|
Thickness (mm) | 1.0 min | Projector profile |
% elongation | 100 min | Shimadzu |
Tenkle strength (MPa) | 11 min | Shimadzu |
Insulation resistance | 92 min | Megger |
Over diameter (mm) | 5.8 major / 3.5 minor | Projector profile |
3.Electical test |
|
|
Resistance @ 20 degree | 80.4max | Portable double |
% conductivity | 30min | Conductance tester |
De-el-citric strength | 7.5@min | megger |