import circuit board medical equipment trolley made in China
USD $5,000 - $10,000 /Unit
Min.Order:1 Unit
Beijing Konted Medical Technology Co., Ltd.
import circuit board medical equipment trolley made in China
Technical Specification
Imaging Modes: | B, B|B, 4B, B|M, M |
Color Doppler (CFM) | |
Power Doppler (PDI) | |
Directional Power Doppler (DPDI) | |
Pulsed Wave Doppler (PWD) | |
B+PWD (Duplex) | |
B+CFM/PDI/DPDI+PWD (Triplex) | |
High Pulse Repetition Frequency (HPRF) | |
Tissue Harmonic Imaging (THI | |
Scanning Method: | electronic linear, electronic convex, electronic micro-convex, scanning depth: 2-24cm |
Color Doppler: | PRF variable: 0.5-9 kHz |
wall filter settings: 3 steps (5%, %10%, 15% PRF) | |
angle steering for linear transducers: ±10° | |
real-time spatial filter: 4 values | |
CFM palette>10 maps | |
PDI palette>10 maps | |
B/Color priority control | |
color threshold control | |
CFM baseline control | |
Doppler frequency selection | |
color frame averaging | |
Transparent Color Mapping (TCM) | |
Pulsed Wave Doppler: | PRF variable: 1-10 kHz |
wall filter settings: 16 steps (2.5%-20% PRF) | |
angle steering for linear transducers: ±10° | |
real-time trace line with automatic calculation of spectrum parameters | |
stereo sound: volume control | |
PWD palette>10 maps | |
Doppler frequency selection | |
Processing: | High Line Density scan mode for better resolution |
8 sliders TGC Control | |
dynamic range>120 dB | |
overall gain control | |
M - mode sweep speed control | |
acoustic power control | |
variable frame averaging | |
brightness, contrast | |
advanced gamma control | |
scan direction, rotation, up-down controls | |
negative / positive control | |
echo enhancement control | |
noise rejection function | |
speckle reduction | |
Image and video: | AVI, JPG, BMP, PNG, TIF, DCM (DICOM) |
General Measurements and Calculations: | Distance, Length, Area, Circumference, Volume, Angle, Stenosis %, A/B Ratio, Velocity, Pressure Gradient (PG), Acceleration, Resistivity Index (RI), Heart Rate, Velocity Time Integral (VTI), etc. |
Expansion interfaces: | VGA, TV Interface |
USB2.0 Interface | |
RJ-45 Network interface | |
Support DeskJet printer, LaserJet printer, video printer |
Application Package
Abdominal,Obstetrics,Gynecology, Urinary System, Cardiology, Radiology, and Organs/Small parts, Musculoskeletal, Pediatrics and Vascular, etc.
Standard Configuration
Host 1 unit;
Convex probe 1 pc;
Linear or Trans-vaginal probe 1 pc
Option
Linear, Trans-vaginal, Micro-convex, Rectal probe;
3D imaging software;
Bag;
Trolley;
Laser Printer;
Video Printer
Images
Probes
Packing: bag &carton.
Shipping: DHL, TNT, UPS, Fedex, ARAMEX, etc
1. Performance assurance through preventative regular maintenance
2. Software upgrades for new features and diagnostics through Internet-based services
3. Up-to-date training materials for the operation and maintenance of equipments
4. Prompt responses to urgent questions by email, phone, or fax
5. Reasonable annual maintenance charges for services after warranty period is over
6. Updates or upgrades, wherever feasible, to equipment with the latest design improvements