60kVA/48kW Mobile soundproof type diesel generator
USD $1 - $99,999 /Set
Min.Order:1 Set
Jiangsu Kangdong International Trade Co., Ltd.
60kVA/48kW Mobile soundproof type diesel generator
1. Specification of genset | ||||||||
Gensets Model | KD-48GF | |||||||
Prime Power(KVA) | 60 | |||||||
Standby Power(KVA) | 66 | |||||||
Rated Voltage(V) | 380 | |||||||
Rated Frequency(HZ) | 50 | |||||||
Rated Speed (rpm) | 1500 | |||||||
Power Factor(COS) | 0.8(lagging) | |||||||
Prime Power(PRP):Prime power is available for an unlimited number of annual hours in variable load application,in accordance with GB/T2820-97;A 10% overload capability is available for a period of 1 hour within a 12-hour of operation. | ||||||||
Standby Power Rating(ESP):The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption.No overload,utility parallel or negotiated outage operation capability is available at this rating. | ||||||||
2. Specification of diesel engine | ||||||||
Engine brand | Cummins | |||||||
Engine model | 4BTA3.9-G2 | |||||||
Number of Cylinders | 4 | |||||||
Cylinder arrangement | Vertical in-line | |||||||
Cycle | Four stroke | |||||||
Aspiration | Turbo charged and Water/Air cooling | |||||||
Fuel System | AD type fuel pump, EFC | |||||||
Bore×Stroke (mm×mm) | 102x120 | |||||||
Displacement (Liter) | 3.9 | |||||||
Compression Ratio | 16.5:1 | |||||||
Speed Governor | Electronic | |||||||
Cooling System | Forced Water Cooling Cycle | |||||||
Total lubrication system capacity (L) | 16.4 | |||||||
Fuel Consumption at 100% Load (g/kwh) | 210 | |||||||
Starting Method | DC24V electrical starting | |||||||
3. Specification of alternator | ||||||||
Alternator brand | Stamford | |||||||
Orgin | WuXi | |||||||
Alternator model | UCI224F | |||||||
Number of Phase | 3 | |||||||
Connecting Type | 3 Phase and 4 Wires | |||||||
Number of Bearing | 1 | |||||||
Protection Grade | IP23 | |||||||
Altitude | ≤1000m | |||||||
Exciter Type | Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire | |||||||
Insulation Class | H | |||||||
Telephone Influence Factor (TIF) | ≤50 | |||||||
THF | ≤2% | |||||||
Voltage Regulation, Steady State | ≤±1% | |||||||
Transient State Voltage | ≤-15%~+20% | |||||||
4. Specification of control Panel | ||||||||
The control panel is AMF control panel, with the display of voltage,current, frequency, water temperature, oil pressure. The genset with low oil pressure,high water temperature,over speed,over load protection function. |