transmission line insulator Ice Shields Device
transmission line insulator Ice Shields Device
transmission line insulator Ice Shields Device
transmission line insulator Ice Shields Device
transmission line insulator Ice Shields Device
transmission line insulator Ice Shields Device

transmission line insulator Ice Shields Device

USD $40 - $100 /Piece

Min.Order:1000 Pieces

Supply Ability:
10000 Piece / Pieces per Month
Port:
Qingdao
Payment Terms:
T/T D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
China
Brand Name:
TID
Model Number:
TBIPD620
Type:
Other, Protective device
Material:
Composite Polymer
Application:
High Voltage

Weinan TID Technology Development Co., Ltd.

Business Type: Manufacturer,Trading Company
Weinan Shaanxi China
Main Products: Composite Wall Bushing ,Composite Insulator ,Composite fue cut out ,Composite surge arrester ,hot line tool&equipment

Product Details

 

 

 

 

 

Products Description
  1. Description of ProductsBird Shields  Device
  2.  View of the Products:

 

 

 

 

transmission line insulator Ice Shields Device

Three color of the products Red ,Green,Yellow can replace the phase sequence card ,the color of the products will never change in the full service life.

 transmission line insulator Ice Shields Device    transmission line insulator Ice Shields Device

transmission line insulator Ice Shields Device   transmission line insulator Ice Shields Device

  1. 1. Technical Character:
  2. 3.1 Birds Protection Principle:

 According to the research of the State Grid,there are more and more evidence to show that ground discharge trip caused by the birds droppings or something droppings.So there is a desgin to protest the insulator by a new device BCPD.

Consider the assemble angle,it is better to use a independent BCPD device which will get a better protection.

We can get from the picture left, β angle bigger,the protection effect better.L is the distance between BCPD shed to the bottom insulator shed,L bigger,protection range will be bigger.

Birds like to make them home on cross arm which is  the top of the insulator ,Their dropping make the electrical field abnormal changing and the dropping make a bridge between the insulator shed,so that there are a lot of flash over or ground discharging problem happened. This BCPD device protect the insulator from two way,One is shield the bird dropping away to the insulator  and frighten the bird fly away and dont make the home here.

                                                       transmission line insulator Ice Shields Device

                 

 

3.2 Ice Protection Principle

 In Winter in the North area,snow ,in bad weather such as soft rime,freezing rain and heavy fog ,The transmission line suspension insulators are very easy to snows and freeze and become soft rime.especially on the composite insulator which have a smaller distance between each shed compared with porcelain insulator and glass insulator.If the insulator freeze ,it is very easy to go through the whole insulator set.when the sun rise out and the temperature get higher,the ice begin to melt .The melt water drop down from the edge of the insulator ,then the leakage current come up bigger ,and then there is a ice and water conduct way come out.then the electrical field change in abnormal way,so make the insulator electrical performance go down,and the flash over and discharge trip happened.Therefor to stop the ice and water bridge on the insulator set is the key point to avoid the ice flash over ,from the drawing above,we can get  β angle bigger,the protection effect better.L is the distance between BCPD shed to the bottom insulator shed,L bigger,protection range will be bigger.

 If we use a BCPD device with the diameter 620mm,It can be protect the length of insulator 850—1000mm,It 98% well protect the top the insulator,The BCPD Device somehow stop the bridge connection and avoid the discharge trip.The BCPD device protect the insulator during the raining day as well.

3.3 The Phase Sequence Distinguish Function,

 BCPD Device can be three colors according the transmission line phase sequence .red ,green,yellow color represent phase A ,B ,C.

3.4  BCPD Device Appearance Design .

    The diameter of the shed up to 620mm which is big enough to shield the length  800mm-1000mm,The surface design is according to aerodynamics character which is hard to polluted and can keep the insulator clean for a longer time.

                                                       transmission line insulator Ice Shields Device

 

 

Bird shields Device

3.5 Technical Detail:

 

 

 

No.Decription of the technical detail Value 
1

Applied range

Suitable for 35KV-110kV transmission line

 porcelain,glass and composite Insulator sets.

2

Diameter

620mm

3

Radian

200

4

Weight

 About 3.2kg
5

 Wind Resistance

 35M/S
6

 Temperature

 -60°- 90°c
7

Volume Resistivity

 ≥10Ω.cm
8

Puncture Voltage

 ≥20KV/mm
9

Arcing Resistance

 ≥100/S
10

Breaking Strength

 ≥10Mpa
11

Hardness

 ≥120
12

Protection Length

 800-1000mm

 

 

 

3.6 BCPD Device installation Instruction:

 

It is very simple to install on line.Install the two part of of BCPD Device into ring of the      suspension insulator ball fitting.I just need to fasten the 4 screw and it doesn’t affect the inspection people working along the conductor by the ladder.The BCPD devices are suitable with porcelain,glass and composite insulator .The inner hole of the BCPD device can be changed according to the power line fittings or insulator fittings which depends on the customers’ requirement.

 

 

Packaging & Shipping

1. Economic Packing desgin which will save your transportation cost.

2. Suitable packing material ( Non fumigaion ) and beautiful package workmanship which will well protect the goods and avoid any trouble when you pick up the goods from the local customs.

transmission line insulator Ice Shields Device 

 

 

 

 

Company Information

transmission line insulator Ice Shields Device 

 

 

Our Services

1. We offer full solution of Technical support.

2. We offer customized Products.

3. We offer Multilingual service.

transmission line insulator Ice Shields Device 

 

Contact Information

transmission line insulator Ice Shields Device CONTACT INFORMATION: 

                           Contact Person:   Amy

                           Skype: Amyan98

                           Tel:0086 2128099

                           Mob:0086 152 9185 9058

                           web:  

 

 

 

 

 

Contact Supplier

Ms. Lucy Liu Chat Now
Telephone
0086-0913-2112960
Mobile
18191816622
Fax
0086-0913-2128099
Address
West DongFeng Dajie Road ,Weinan high Technology industrial Zone Shaanxi Weinan,Shaanxi

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Electronic Accessories & Supplies > Insulation Materials & Elements
Categories
Hi~