low voltage 2 core copper conductor electric wire 1.5mm 2.5mm
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
1.Our CU-core PVC Insulated electrical wires has passed CCC and ISO qualified, IEC standard
2.best quality with the best price
1.450/750 Cu conductor PVC insulated electric wire belong to the series of laying electrical wire,which is mainly suitable for laying at the fixed places.It is widely used as lighting,connectors of drive, electric equipments,instrument and telecommunication equipments.The rated voltage is 450/750V(U0/U) or below.Part of the plastic wires are used at the equipment with AC rated voltage up to 300/300V .
2.Electric wire is usually PVC insulated wire.This system include the below types
BV,,BV-90,BVR, BVV,BLVV,BVVB,BLVVB,RVB,RVS,RVV
BVCopper (aluminum) conductor PVC insulated w
BLValuminum) conductor PVC insulated wires
BVR Copper conductor PVC insulated flexible wires)* Copper (aluminum) conductor PVC insulated PVC sheathed round wires
* Copper (aluminum) conductor PVC insulated PVC sheathed flat wires
* Copper conductor PVC insulated flat flexible connectors
* Copper conductor PVC insulated PVC sheathed round flexible connectors* Sizes: 0.5-185mm2*
3.Standard: GB Standard and IEC Standard.
GB 5023.11997450/750V or below PVC insulated electric wires,JB 8734.15-1998450/750V or under PVC insulated cables,electric wires and flexible wiresand Q/ZEL 02-2002Piastic insulated electric wires and cables.GB 5023.17-1997 is identical to IEC227,and type are same as the stipulation of IEC,technical specification is just the same,and more we have extended the range of the type to fit for the requipment of the consumers.
We can also produce as per the other special requirements of the clients.
Product:
Type | Name | Laying place and requirement | Long term working temperature |
227IEC01/05 BV | Copper conductor PVC insulated wires | Fixed laid indoors, conduits etc. |
70 |
BL V | Aluminum Conductor PVC insulated wires | ||
227IEC07 BV-90 | Heat resistant copper conductor PVC insulated wires at 90 | Mainly be laid at the places of high temperature environment and can be laid indoors, conduits. | 90 |
BVR | Copper conductor PVC insulated flexible wire | Be for laying permanent place where flexible required. |
70 |
227IEC10 BVV | Copper conductor PVC insulated PVC sheathed round wires | Fixed laid, fit for the places with high mechanical protection and moisture place. Can be laid in the air or underground. |
70 |
BLVV | Aluminum conductor PVC insulated PVC sheathed round wires | ||
BVVB | Copper conductor PVC insulated PVC Sheathed flat wires | 90 | |
BLVVB | Aluminum conductor PVC insulated sheathed flat wires |
| 70 |
227IEC02RV 227IEC06RV | Copper conductor PVC insulated flexible connector | Mainly used at middle and light style of moving electronics, home appliances, power and lighting and the places where flexible required. | 70 |
227IEC42 RVB | Copper conductor PVC insulated flat flexible connector | ||
RVS |
Copper conductor PVC insulated flexible twisting connector wire | ||
227IEC52 RVV 227IEC53 RVV | Copper conductor PVC insulated PVC sheathed round flexible connector(light and common type) |
Specification Size and Technical Data
Commen wire
Nominal sectional area mm2 | Conductor No/Dia. mm | Nominal Insulated thick mm | Max overall Dia. mm | Condcutor Resistance at 20 | Min insulated resistance at 70MΩ/km | Weight Kg/km | ||
Cu | Al | Cu | Al | |||||
1.5 | 1/1.38 | 0.7 | 3.3 | 12.1 | - | 0.011 | 19.2 | - |
1.5 | 7/0.52 | 0.7 | 3.5 | 12.1 | - | 0.010 | 20.6 | - |
2.5 | 1/1.78 | 0.8 | 3.9 | 7.41 | 11.8 | 0.010 | 30.8 | 15.0 |
4 | 1/2.25 | 0.8 | 4.4 | 4.61 | 7.39 | 0.0085 | 45.5 | 21.0 |
6 | 1/2.76 | 0.8 | 4.9 | 3.08 | 4.91 | 0.0070 | 65.0 | 29.0 |
10 | 7/1.35 | 1.0 | 7.0 | 1.83 | 3.08 | 0.0065 | 110.0 | 52.0 |
16 | 7/1.70 | 1.0 | 8.0 | 1.15 | 1.91 | 0.0050 | 170.0 | 70.0 |
25 | 7/2.14 | 1.2 | 10.0 | 0.727 | 1.20 | 0.0050 | 270.0 | 110.0 |
35 | 7/2.52 | 1.2 | 11.5 | 0.524 | 0.868 | 0.0040 | 364.0 | 150.0 |
50 | 19/1.78 | 1.4 | 13.0 | 0.387 | 0.641 | 0.0045 | 500.0 | 200.0 |
70 | 19/2.14 | 1.4 | 15.0 | 0.268 | 0.443 | 0.0035 | 688.0 | 269.0 |
95 | 19/2.52 | 1.6 | 17.5 | 0.193 | 0.320 | 0.0035 | 953.0 | 360.0 |
120 | 37/2.03 | 1.6 | 19.0 | 0.153 | 0.253 | 0.0032 | 1168.0 | 449.0 |
150 | 37/2.25 | 1.8 | 21.0 | 0.124 | 0.206 | 0.0032 | 1466.0 | 551.0 |
185 | 37/2.52 | 2.0 | 32.5 | 0.099 | 0.164 | 0.0032 | 1808.0 | 668.0 |
Flexible wire
Nominal sectional area mm2 | Conductor No/Dia. mm | Nominal Insulated thick mm | Max overall Dia. mm | Condcutor Resistance at 20 | Min insulated resistance at 70MΩ/km | Weight Kg/km |
2.5 | 9/0.41 | 0.8 | 4.2 | 7.41 | 0.011 | 33.0 |
4 | 19/0.52 | 0.8 | 4.8 | 4.61 | 0.009 | 48.0 |
6 | 19/0.64 | 0.8 | 5.6 | 3.08 | 0.0084 | 68.0 |
10 | 49/0.52 | 1.0 | 7.6 | 1.83 | 0.0072 | 115.0 |
16 | 49/0.64 | 1.0 | 8.8 | 1.15 | 0.0062 | 176.0 |
25 | 98/0.58 | 1.2 | 11.0 | 0.727 | 0.0058 | 272.0 |
35 | 133/0.58 | 1.2 | 12.5 | 0.524 | 0.0052 | 384.0 |
50 | 133/0.68 | 1.4 | 16.5 | 0.387 | 0.0051 | 510.0 |
70 | 189/0.68 | 1.4 | 16.5 | 0.268 | 0.0045 | 714.0 |
95 | 259/0.68 | 1. | 19.5 | 0.139 | 0.0035 | 965.0 |
120 | 259/0.76 | 1.8 | 22.0 | 0.153 | 0.0032 | 1210.0 |
150 | 259/0.85 | 1.8 | 25.0 | 0.124 | 0.0032 | 1510.0 |