IEC standard Aluminum Stranded Wire and Aluminum Conductor Steel-reinforced
USD $1 - $500 /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Best Overhead Types of AAC ACSR ACAR AAAC Bare Overhead Cable types of acsr wire
Best Overhead Types of AAC ACSR ACAR AAAC Bare Overhead Cable types of acsr aerial cable
Best Overhead Types of AAC ACSR ACAR AAAC Bare Overhead Cable types of acsr conductor cable
Best Overhead Types of AAC ACSR ACAR AAAC Bare Overhead Cable types of acsr penguin cable
Aluminum Stranded Wire and Aluminum Conductor Steel-reinforced
Application
The Aluminum Stranded Wire and Aluminum Conductor Steel-reinforced apply for electric transmission line overhead.
Specification and Produce range
No. | Specification | Name | Cross-sectional area | Standard |
1 | LJ | Aluminum stranded wire | 16~800 | GB/T1179-1999 |
2 | LGJ | Aluminum conductor steel-reinforced | 10/2~800/100 | |
3 | LGJF | Anticorrosive aluminum conductor steel-reinforced | 10/2~800/100 | |
4 | JL | Aluminum stranded wire | 10~800 | GB/T 1179-1999 |
5 | JLHA2,JLHA1 | Aluminum alloy stranded wire | 16~800 | |
6 | JL/G1A,JL/G1B,JL/G2A,JL/G2B,JL/G3A | Aluminum conductor steel-reinforced | 16~800 | |
7 | JL/G1AF,JL/G2AF,JL/G3AF | Anticorrosive aluminum conductor steel-reinforced | 16~800 | |
8 | JLHA2/G1A,JLHA2/G1B,JLHA2/G3A | Aluminum alloy conductor steel-reinforced | 16~800 | |
9 | JLHA1/G1A,JLHA1/G1B,JLHA1/G3A | Aluminum alloy conductor steel-reinforced | 16~800 | |
10 | JL/LHA2,JL/LHA1 | Aluminum conductor aluminum alloy reinforced | 16~800 | |
11 | JL/LB1A | Aluminum conductor aluminum coated steel-reinforced | 16~800 | |
12 | JLHA2/LB1A,JLHA1/LB1A | Aluminum alloy conductor aluminum coated steel-reinforced | 16~800 | |
13 | JG1A,JG1B,JG2A,JG3A | Steel stranded wire | 4~63 | |
14 | JLB1A,JLB1B,JLB2 | Aluminum coated steel stranded wire | 4~200 |
Technical Data
Aluminum Stranded Wire
Nominal cross-sectional area mm2 | Construction No. /Diameter mm | Calculated cross-section mm2 | Overall diameter mm | D.C. resistance of conductor Ω/km | Calculated tensile force N |
Appro. Weight kg/km | Delivery length m |
16 | 7/1.70 | 15.89 | 5.1 | 1.802 | 2840 | 43 | 4000 |
25 | 7/2.15 | 25.41 | 6.4 | 1.127 | 4355 | 69 | 3000 |
35 | 7/2.50 | 34.36 | 7.5 | 0.8332 | 5760 | 94 | 2000 |
50 | 7/3.00 | 49.48 | 9.0 | 0.5786 | 7930 | 135 | 1500 |
... | |||||||
400 | 37/3.70 | 397.83 | 25.9 | 0.07247 | 61150 | 1097 | 1000 |
500 | 37/4.16 | 502.90 | 29.1 | 0.05733 | 76370 | 1387 | 1000 |
630 | 61/3.63 | 631.30 | 32.6 | 0.04577 | 91940 | 1744 | 800 |
800 | 61/4.10 | 805.36 | 36.9 | 0.03588 | 115900 | 2225 | 800 |
GB/T1179-1999
Aluminum Stranded Wire
Specification | Cross-sectional mm2 | No. of single wire N | Diameter | Weight kg/km | Rated tensile force kN | D.C. resistance of conductor at 20℃ Ω/km | |
Single wire mm | Stranded conductor mm | ||||||
10 | 10 | 7 | 1.35 | 4.05 | 27 | 1.95 | 2.8633 |
16 | 16 | 7 | 1.71 | 5.12 | 43 | 3.04 | 1.7896 |
25 | 25 | 7 | 2.13 | 6.40 | 68 | 4.50 | 1.1453 |
40 | 40 | 7 | 2.70 | 8.09 | 109 | 6.80 | 0.7158 |
63 | 63 | 7 | 3.39 | 10.2 | 172 | 10.39 | 0.4545 |
100 | 100 | 19 | 2.59 | 12.9 | 274 | 17.00 | 0.2877 |
125 | 125 | 19 | 2.89 | 14.5 | 343 | 21.25 | 0.2302 |
160 | 160 | 19 | 3.27 | 16.4 | 439 | 26.40 | 0.1798 |
... | |||||||
1120 | 1120 | 91 | 3.96 | 43.5 | 3093 | 179.20 | 0.0258 |
1250 | 1250 | 91 | 4.18 | 46.0 | 3452 | 200.00 | 0.0231 |
1400 | 1400 | 91 | 4.43 | 48.7 | 3866 | 224.00 | 0.0207 |
1500 | 1500 | 91 | 4.58 | 50.4 | 4143 | 240.00 | 0.0193 |
GB/T1179-1999
Aluminum Conductor steel-reinforced
Speci- fica- tion | % Steel rate | Area | No. of wire | Diameter of single wire | Diameter | Weight kg/km | Rated tensile force | 20℃ D.C. resistance of conductor at 20℃ Ω/km | ||||||||||||
Al. | St. | Total | Al. | St. | Al. | St. | Steel core | Conductor | JL/G1A | JL/G1B | JL/G2A | JL/G2B | JL/G3A | |||||||
mm2 | mm | mm | KN | |||||||||||||||||
16 | 17 | 16 | 2.67 | 18.7 | 6 | 1 | 1.84 | 1.84 | 1.84 | 5.53 | 64 | 6.08 | 5.89 | 6.45 | 6.27 | 6.83 | 1.7934 | |||
25 | 17 | 25 | 4.17 | 29.2 | 6 | 1 | 2.30 | 2.30 | 2.30 | 6.91 | 100 | 9.13 | 8.83 | 9.71 | 9.42 | 10.25 | 1.1478 | |||
40 | 17 | 40 | 6.67 | 46.7 | 6 | 1 | 2.91 | 2.91 | 2.91 | 8.74 | 161 | 14.40 | 13.93 | 15.33 | 14.87 | 16.20 | 0.7174 | |||
63 | 17 | 63 | 10.5 | 73.5 | 6 | 1 | 3.66 | 3.66 | 3.66 | 11.0 | 254 | 21.63 | 20.58 | 22.37 | 21.63 | 24.15 | 0.4555 | |||
... | ||||||||||||||||||||
1000 | 4 | 1000 | 43.2 | 1043 | 72 | 7 | 4.21 | 2.80 | 8.41 | 42.1 | 3100 | 209.26 | 206.23 | 215.31 | 212.28 | 220.93 | 0.0289 | |||
1120 | 4 | 1120 | 47.3 | 1167 | 72 | 19 | 4.45 | 1.78 | 8.90 | 44.5 | 3464 | 234.53 | 231.22 | 241.15 | 237.84 | 247.77 | 0.0258 | |||
1120 | 8 | 1120 | 91.2 | 1211 | 84 | 19 | 4.12 | 2.47 | 12.4 | 45.3 | 3811 | 283.17 | 276.78 | 295.94 | 289.55 | 307.79 | 0.0258 | |||
1250 | 4 | 1250 | 52.8 | 1303 | 72 | 19 | 4.70 | 1.88 | 9.40 | 47.0 | 3867 | 261.75 | 258.06 | 269.14 | 265.44 | 276.53 | 0.0231 | |||
1250 | 8 | 1250 | 102 | 1352 | 84 | 19 | 4.35 | 2.61 | 13.1 | 47.9 | 4253 | 316.04 | 308.91 | 330.29 | 232.16 | 343.52 | 0.0232 | |||
The data in above table also fit for anti-corrosive Aluminum conductor steel reinforced with the specification JFL/G1A,JFL/G2A,JFL/G3A.
Aluminum conductor steel-reinforced and Anti-corrosive Aluminum conductor steel-reinforced
Nominal cross-sectional Al./St. mm2 | Construction No./Diameter mm | Calculated cross-section mm2 | Overall diameter mm | D.C. resistance of conductor
Ω/km | Calculated tensile force N | Appro. Weight kg/km | Delivery length m | |||
Al. | St. | Al. | St. | Total | ||||||
10/2 | 6/1.50 | 1/1.50 | 10.60 | 1.77 | 12.37 | 4.5 | 2.706 | 4.12 | 42 | 3000 |
16/3 | 6/1.85 | 1/1.85 | 16.13 | 2.69 | 18.82 | 5.5 | 1.779 | 6.13 | 65 | 3000 |
25/4 | 6/2.32 | 1/2.32 | 25.36 | 4.23 | 29.59 | 6.9 | 1.131 | 9.29 | 102 | 3000 |
35/6 | 6/2.72 | 1/2.72 | 34.86 | 5.81 | 40.67 | 8.1 | 0.8230 | 12.63 | 141 | 3000 |
50/8 | 6/3.20 | 1/3.20 | 48.25 | 8.04 | 56.29 | 9.6 | 0.5946 | 16.87 | 195 | 2000 |
... | .... | |||||||||
630/45 | 45/4.20 | 7/2.80 | 623.45 | 43.10 | 666.55 | 33.6 | 0.04633 | 148.70 | 2060 | 1200 |
630/55 | 48/4.12 | 7/3.20 | 639.92 | 56.30 | 696.22 | 34.3 | 0.04514 | 164.40 | 2209 | 1200 |
630/80 | 54/3.87 | 19/2.32 | 635.19 | 80.32 | 715.51 | 34.8 | 0.04551 | 192.90 | 2388 | 1200 |
800/55 | 45/4.80 | 7/3.20 | 814.30 | 56.30 | 870.60 | 38.4 | 0.03547 | 191.50 | 2690 | 1000 |
800/70 | 48/4.63 | 7/3.60 | 808.15 | 71.25 | 879.40 | 38.5 | 0.03574 | 207.00 | 2791 | 1000 |
800/100 | 54/4.33 | 19/2.60 | 795.17 | 100.88 | 896.05 | 38.9 | 0.03635 | 241.10 | 2991 | 1000 |
If you have any questions, pls don't hesitate to contact me! |
Morgan |
Hebei New Baofeng Wire & Cable Co.,Ltd |
ADD: Jinghe Industrial Zone, Hejian City, Hebei Province China |
Email: sales4 at |
Tel: 86-531-58617867 |Mob:86-15098767265 |
Fax: 86-531-88015590 |Skype: morganren-china|QQ:1733109349 |
Website: http://nbfcable.en.china.cn/ /english/about.asp |