Separated Pressurized Solar water heaters

Separated Pressurized Solar water heaters

USD $1,200 - $1,600 /Set

Min.Order:1 Set

Supply Ability:
100 Set / Sets per Month
Port:
Shanghai or Ningbo
Payment Terms:
T/T

Quick Details View All >

Type:
Evacuated Tube
Pressure:
Pressurized
Circulation Type:
Indirect / Closed Loop (Active)
Heating System:
Thermosyphon (Passive)
Connection Type:
Split
Installation:
Freestanding

Haining Jineng Solar Energy Industry Co., Ltd.

Business Type: Manufacturer
Jiaxing Zhejiang China
Main Products: Solar Water Heater ,Solar Collector ,Pressurized Solar Water Heater ,Split solar system ,Solar Heating Project

Product Details

Separated Pressurized solar water heaters

 

Model:JNSP

 

 Separated Pressurized Solar water heaters

 

 

 

The cold water flows into the solar water storage tank directly and is stored there. The solar collector absorbs sunlight and converts it into heat energy, thus the temperature of medium in the heat pipe becomes higher. Meanwhile, the sensors will detect the temperature in collector and water tank, and then send the data to the intelligent controller. The microcomputer system will process the data and under the condition that the temperature difference reaches the setting value, the circulation pump stats to work. So the medium in the collector is transferred into the coil in the tank which is used to exchange heat, and the cold water flows near the coil and the temperature rises. One circulation finished. Thus the temperature of water will gradually rise to the setting value by repeating the circulation process.

 

 (1) Working on sunny day                                                (2) working on rainy or claudy day

 Separated Pressurized Solar water heaters

 

 

 

 

Separated Pressurized Solar water heaters 

 

1) Storage water tank

 

Storage tank is separated from the heat collector and it is pressurized type, thus it has a very thick inner tank which is made of SUS304 or 316L stainless steel, and the thickness depends on the tank capacity. The main material used for outer tank is color steel or stainless steel. According to the circulating system, our tank can be divided into three categories which are non coil type, single copper coil type and double copper coils type. Also pressure reducing valve, check valve, magnesium bar and electric heater are all equipped with the tank to form a perfect working system in combination with the collector and working station. In addition, the specially designed structure of the water tank avoids the mixing of cold and hot water.

 

Separated Pressurized Solar water heaters

 

 

 

 

 

 2.WORKING STATION

 

 Separated Pressurized Solar water heaters 

     1. Dimension: 380×220×140mm     2. Input voltage: 200V~240V AC or 100V~120V AC

 

     3. Power: ≤3W   4. Accuracy of temperature measuring: ±1°C

 

     5. Range of temperature measuring: PT1000 : 0~199°C NTC10K: 0~99°C

 

     6. Input signals:

 

       1 x PT1000 sensor temperature probe ≤500°C, silicon cable ≤280°C;

 

       2 x NTC10K sensor temperature probe≤135°C, PVC cable ≤105°C

 

     7. Output signals:

 

       1 x Auxiliary heating output (Max. load current: 12A)

 

       2 x Relay output (Max. load current: 3A)

 

     8. System design pressure: 1 MPa            9. Safety valve respond pressure: 0.6 MPa

 

    10. WILO pump model: RS15/6                   11. Screw coupling: 1/2

 

    12. Pipeline Material: Brass

 

    13. Secondary display screen (For selection)                         14. LCD-display

 

    15. Range of environment temperature: -10~50°C                16. Water protection grade: IP40

 

 

 

  3. Solar Collectors 

 

 

 

    Headbox: 2.0mm aluminum alloy                                           Collector: 58-1800/47-1500mm three target tube

 

     Frame: 2.0mm aluminum alloy                                                Heat pipe condensor: 14mm/20mm/24mm

 

    Condensor resulation: Nikel-plated heat pipe                      U-tube copper pipe solar collectors

 

 Separated Pressurized Solar water heaters

 

 

 

Separated Pressurized Solar water heaters

 

 

 

Mould

Collector

Absorber area

(m2)

Tank capacity

( L)

Measurement

(M3)

Gross weight

one coil/ two coils

( kg)

20'GP/40'GP/ 40HG

JNSP-100

58-1800-10

0.82

100

0.58

68/74

47/94/116

 

58-1800-12

0.98

 

0.6

74/80

46/91/112

JNSP-150

58-1800-15

1.22

150

0.74

90/96

37/73/91

 

58-1800-18

1.46

 

0.78

100/106

35/70/86

JNSP-200

58-1800-20

1.62

200

0.92

121/127

30/59/73

 

58-1800-24

1.95

 

0.96

134/140

28/56/70

JNSP-300

58-1800-30

2.45

300

1.25

162/168

22/43/54

 

58-1800-36

2.92

 

1.38

184/190

20/39/49

JNSP-400

58-1800-40

3.24

400

1.67

209/215

16/32/40

JNSP-500

58-1800-50

4.06

500

2.02

256/262

14/27/33

 

 Separated Pressurized Solar water heaters

 

 

 

Separated Pressurized Solar water heaters

 

 

 

Separated Pressurized Solar water heaters

 

 

 

 1. Solar for Central Heating-Preventing Overheating

 

If a system has been designed to provide contribution to central heating, it will often provide much more heat in the summer than is required for hot water supply alone. In such cases it is advisable for the home to have a spa or pool that can use the heat in the summer period or a heat dissipation device be installed.

 

2. Metallic Components

 

Always wear glove when handing the various solar collector components. All efforts have been made to make the metal components safe to handle, but there may still be some sharp edges.

 

3. Evacuated Tubes

 

Be careful when handing the evacuated tubes, as they will break if knocked heavily or dropped. Wear gloves if handing any broken glass.

 

4. High Temperatures

 

With the heat pipe installed in the evacuated tube, and good sunlight, the heat pipe condenser can reach temperatures in excess of 200°C/392°F. At this temperature touching the heat pipe will result in serious burns, so please take care when ” experimenting ” with, or “demonstrating ” the evacuated tube and heat pipes .In an installed, fully plumbed system, if the pump is stopped during good sunlight, the collector header and plumbing pipe close to the manifold can reach temperatures of 160°C/320°F, and therefore caution should be taken when touching such components.

 

 

 

Contact Supplier

Ms. Annie Zhang Sales Manager Chat Now
Telephone
86-573-87096388
Mobile
86-13586321562
Fax
86-573-87293344
Address
No. 9 Danjing Road, Haichang Economic Development Zone, Haining City, Zhejiang Province, China Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Home Appliances > Water Heaters > Solar Water Heaters
Categories
Hi~