EPDM tube bubble membrane diffuser
USD $10 - $20 /Piece
Min.Order:1 Piece
Yixing Huixing Plastics Co., Ltd.
The specification of tube membrane diffuser
The size have 60mm, 65mm,70mm, 75mm , 90mm .
Details pls contact with us , we could give you the detail technical parameter
Item | Φ67mm*500mm | Φ67mm*750mm | Φ67mm*1000mm |
Oxygen transform efficiency (%) | >30 | >30 | >30 |
Working air flow (m3/h) | 1-5 | 1-7 | 1-12 |
Designed air flow(m3/h) | 3 | 5 | 7 |
Service area (m2/piece) | 0.45-1 | 0.5-1.2 | 0.75-1.5 |
Hole number(pc) | 8080 | 12300 | 16880 |
Bubble dia (mm) | 1-3 | 1-3 | 1-3 |
Drag loss (pa) | <3000 | <3000 | <3000 |
Oxygenate capability (kgO2/h) | 0.45 | 0.55 | 0.65 |
Theoretic dynamic efficency(kgO2/kw.h) | 6.5 | 7 | 7.5 |
Item | Φ75mm*500mm | Φ75mm*750mm | Φ75mm*1000mm |
Oxygen transform efficiency (%) | >30 | >30 | >30 |
Working air flow (m3/h) | 2-7 | 3-8 | 4-12 |
Designed air flow(m3/h) | 5 | 7 | 10 |
Service area (m2/piece) | 0.75-1.5 | 1-1.8 | 1.5-2.5 |
Hole number(pc) | 8650 | 12500 | 17400 |
Bubble dia (mm) | 1-3 | 1-3 | 1-3 |
Drag loss (pa) | <3000 | <3000 | <3000 |
Oxygenate capability (kgO2/h) | 0.55 | 0.75 | 1.0 |
Theoretic dynamic efficency(kgO2/kw.h) | 7 | 7.5 | 8 |
Item | Φ90mm*500mm | Φ90mm*750mm | Φ90mm*1000mm |
Oxygen transform efficiency (%) | >30 | >30 | >30 |
Working air flow (m3/h) | 4-10 | 5-12 | 6-18 |
Designed air flow(m3/h) | 6 | 8 | 12 |
Service area (m2/piece) | 0.75-1.5 | 1.25-2.5 | 1.75-3 |
Hole number(pc) | 9620 | 15175 | 19400 |
Bubble dia (mm) | 1-3 | 1-3 | 1-3 |
Drag loss (pa) | <3000 | <3000 | <3000 |
Oxygenate capability (kgO2/h) | 0.65 | 0.85 | 1.25 |
Theoretic dynamic efficency(kgO2/kw.h) | 7.25 | 8 | 8.5 |
Item | Φ110mm*500mm | Φ110mm*750mm | Φ110mm*1000mm |
Oxygen transform efficiency (%) | >30 | >30 | >30 |
Working air flow (m3/h) | 6-12 | 9-18 | 12-24 |
Designed air flow(m3/h) | 7 | 10 | 15 |
Service area (m2/piece) | 1.15-2.25 | 2.28-4.75 | 6-8.85 |
Hole number(pc) | 14300 | 20400 | 28600 |
dia (mm) | 1-3 | 1-3 | 1-3 |
Drag loss (pa) | <3000 | <3000 | <3000 |
Oxygenate capability (kgO2/h) | 0.85 | 1.10 | 1.55 |
Theoretic dynamic efficency(kgO2/kw.h) | 7.5 | 8.5 | 9 |