S series single output switching power supply 120W
Negotiable /Piece
Min.Order:400 Pieces
Zhejiang Carspa New Energy Co., Ltd.
Normal single switching power supply S-120W
Features:
·AC input voltage range selected by switch
·Small volume, low weight, high efficiency
·Protections: short circuit/over load
·Cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Year warranty
S-120W
Model | S-120-5 | S-120-12 | S-120-15 | S-120-24 | S-120-36 | S-120-48 | |
Output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 24A | 10A | 8A | 5A | 3.33A | 2.5A | |
Current range | 0~24A | 0~10A | 0~8A | 0~5A | 0~3.33A | 0~2.5A | |
Rated power | 120W | 120W | 120W | 120W | 119.8W | 120W | |
Ripple&noise | 100mvp-p | 120mvp-p | 120mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Input | Voltage range | 90~132VAC/180~264VAC(selected by switch), 255~373VDC | |||||
Frequency | 47~63Hz | ||||||
AC current | 2.4A/115VAC,1.2A/230VAC | ||||||
Efficiency | 78% | 80% | 80% | 82% | 82% | 83% | |
Inrush current | cold start current 18A/115VAC, 36A/230VAC | ||||||
Leakage current | < 3.5mA/240VAC | ||||||
Protection | Overload | above 115%~150% rated power | |||||
protection type: cutoff output, recovery after restart power | |||||||
Environment | working temp,humidity | -10°C~+60°C, 20%~90%RH | |||||
storagetemp,humidity | -20°C~+85°C, 10%~95%RH non-condensing | ||||||
withstand vibration | 10~500Hz,2G 10min/1cycle, period for 60 minutes, each axes | ||||||
Safety | withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC | ||||||
Fitstandard | Safety standard | Fit UL1012 | |||||
EMC standard | meet EN55022, CLASS A | ||||||
Others | Dimension | 199*98*38mm (L*W*H) | |||||
Weight/packing | 0.6kg/30pcs/19kg/0.034 m³/1.2CUFT | ||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |