Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing
Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing
Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

USD $8,000 - $15,000 /Set

Min.Order:1 Set

Supply Ability:
5000 Set / Sets per Month
Port:
Shanghai/Be appointed
Payment Terms:
T/T L/C D/P D/A

Quick Details View All >

Place of Origin:
Hubei, China
Brand Name:
Keyland/OEM
Model Number:
GTC-A/B
Power:
Electronic
Usage:
Other, Solar Cell Test

Jiangsu Keyland Laser Technology Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer
Wuhan Hubei China
Main Products: Solar Equipment Solar Panel Making Line Equipment ,Solar Cell Tester ,Solar Cell Scribing Machine ,Solar Simulator ,Solar EL Defector ,Laser Machine Laser Marking Machine ,Laser Cutting Machine ,Laser Engraving Machine

Product Details

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells  Simulator

for Recording IV Testing 

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

Solar Cells Simulator  is Mainly used in automatic test and result record of solar mono-Sipoly-Si solar cell module.

Testing Range:0.1-5W 200mm*200mm

Xenon lamp liftspan is ≥100,000 times

ONline Full Automatic Solar Cells Simulators can be supplied according to your full solar line

 

 Spec. of  Solar Cells Simulator :

Model

GTC-3A

GTC-AAB

Lamp Spectrum

In line with IEC60904-9 and JISC8933( A Grade )

Light intensity

100mW/cm2 (continuous adjustable range 20-120W/cm2)

Light intensity non-uniformity

≤±2% A grade 

≤±3%

Instability degree of irradiation

≤±2% A grade

≤±2%

Test result consistency

≤±0.5%A grade

≤±1%

Test error of electrical properties

≤2%

Single flash time

10-30ms

Effective Test range 

200x200mm/0.1-5W

Measuring voltage

0~0.8V(resolution 1mV)

Measuring current

0~20A(resolution 1mA)

Test Parameters

1sc, Voc, Pmax, Vm, Im, FF, EFF, Temp, Rs, Rsh

Options of  Solar Cells Simulator  :

To satisfy the test requirements of double grid lines,3-grid-line,0-grid-line.

 

Technology characters of   Solar Cells simulator :

A grade spectrum;

A grade unevenness degree of irradiance;

A grade instability degree of irradiation;

A grade test error,

A grade repeat test error;

 

HMI and PLC intelligent control,touch screen control;

Built-in host,industrial integration design,and more in line with the industrial application environment;

360 degree freely show frame,facilitate date collection. 

 

Pneumatic and buffering contact, front probe contact, back contact

 

4-line survey,14-bit 4-channel high-speed synchronous acquisition

10 parameters display;8000 data collecting dots

 

Irradiance&Temperature compensating automatically

 

Measurement parameter displays in tabulation and graphic way;

 

Voice counts off and prompts; Counting prompt of flash times;24hrs continuous working; 

 Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

By the way, we also manufacture a series  solar panel production line machines:

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

Service & Train of Solar cells simulator in our clients factories

 

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

Video by our Keyland solar Equipments

 

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

 

https://youtu.be/NHtwZ4lONQYhttps://youtu.be/watySlfaQCI
http://youtu.be/OiTKxQjAet4http://youtu.be/kqK8VpAvAxo
http://youtu.be/Q2P5d5Mt5PMhttp://youtu.be/Keim3fiX4bs
http://youtu.be/Gn4o-mehIVMhttp://youtu.be/OP7KP_5mcwI

 http://youtu.be/zjmC9HVnfDs

http://youtu.be/c3D-lOTIPLc

 

Keyland OverSea Service

 

 Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

 

Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

 

Welcome to contact Lucia Lv for more details 

 

We will design suitable solar line project with competitive cost to you .

 

Hope to buid cooperation

 

 Keyland Double /Three Grid Line GTC-AAB /AAA Solar Cells Simulator for Recording IV Testing

 

NEWS♥

 

1.Our own 300MW solar panel making line has built in LA USA NOW.

 

2.1MW Solar panel production line has built in Turkey 

 

3.5MW Solar panel manufacturing line has built in India

 

 

 

Why Choose Keyland for solar  equipment & Line?

 

1. On-site engineers :More than 5 years for solar field

 

2.Engineers Professional /Understand-English 

 

3.We are BIG manufacturer,but not trading company.

 

4.Our service is not only for on-site service,but our warranty is lifespan.

 

Professional Solar Line Solution-Professional Engineer Team

 

To help you build a low cost /steady /hi- efficient project.

 

5.Be care, absconding with money's small trading companies.

 

 

 

Cooperation with us ,your business in safe; Your money in safe.

 


 

 

 

                                        

 

 

 

 

 

 

 

 

 

 

 


 

Contact Supplier

Mr. keyland laser Chat Now
Telephone
86-27-87970567
Address
Block B, Phoenix Park, Changzui Industrial Park, Gaoxin 6th Road, East Lake Development Zone Wuhan,Hubei