LC1-D(JX2) series A.C. contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9-330A under AC-3 duty. It is mainly used for making/breaking electric circuits at a long distance & for frequent starting/stopping & controlling A.C. Motors. It is used in combination with thermal relay to compose a magnetic motor starter.
Specification:
Type | LC1-D09 | LC1-D12 | LC1-D18 | LC1-D25 | LC1-D32 | |
Rated working current (A) | AC3 | 9 | 12 | 18 | 25 | 32 |
AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | |
AC3 capacity of phase 3 squirrel-cage motor AC3(kW) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | |
415V | 4 | 5.5 | 9 | 11 | 15 | |
440V | 4 | 5.5 | 9 | 11 | 15 | |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | |
Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | |
Electrical life | AC4 x 104 | 20 | 20-15 | 20-7 | 15-7 | 15-7 |
AC3 x 106 | 2 | 2 | 2 | 2 | 2 | |
Mechanical | 20 | 20 | 20 | 20 | 20 | |
Number of the contact | 3P+NO | |||||
3P+NC |
Type | LC1-D40 | LC1-D50 | LC1-D65 | LC1-D80 | LC1-D95 | |
Rated working current (A) | AC3 | 40 | 50 | 65 | 80 | 95 |
AC4 | 18.5 | 24 | 28 | 37 | 44 | |
AC3 capacity of phase 3 squirrel-cage motor AC3(kW) | 220/230V | 11 | 15 | 18.5 | 22 | 25 |
380/400V | 18.5 | 22 | 30 | 37 | 45 | |
415V | 22 | 25 | 37 | 45 | 45 | |
440V | 22 | 30 | 37 | 45 | 45 | |
500V | 22 | 30 | 37 | 55 | 55 | |
660/690V | 30 | 33 | 37 | 45 | 45 | |
Rated heat current (A) | 60 | 80 | 80 | 125 | 125 | |
Electrical life | AC4 x 104 | 10-7 | 7 | 7-6 | 7-5 | 7-5 |
AC3 x 106 | 2 | 2 | 1.6 | 1.6 | 1.6 | |
Mechanical | 20 | 20 | 20 | 10 | 10 | |
Number of the contact | 3P+NC+NO |
Outline and installation dimension: