Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit
Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

USD $1 - $50 /Piece

Min.Order:1 Piece

Supply Ability:
100000 Piece / Pieces per Month
Port:
Hongkong/Shenzhen
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

Products Status:
Stock
Type:
Wired
Application:
Enterprise
Function:
Firewall, QoS
LAN Ports:
15
WAN Ports:
2

POLYTRADE SRL

Credit Member 4 years
Business Type: Manufacturer,Trading Company,Distributor/Wholesaler
Buenos Aires Argentina
Main Products: Huawei ZTE GPON EPON OLT ONU ,Transmission ,DSLAM & CPE ,Emerson Power Battery ,Switch Router

Product Details

Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit E

 

Product Description

HUAWEI NetEngine NE40E universal service router NE40E-X16 NE40E-X8 NE40E-X3

 

The NE40E series Universal Service Router (USR) is a high-end network product, features line-rate forwarding capability, a well-designed Quality of Service (QoS) mechanism, strong service-processing capability, and excellent expansibility and usually deployed at the edges of Internet Protocol (IP) backbone networks, IP Metropolitan Area Networks (MANs), Internet Data Centers (IDCs) networks and other large-scale IP networks. The NE40E can provide comprehensive services for enterprises and residential areas as a universal edge device.
Based on distributed hardware forwarding and non-blocking switching technologies, the NE40E provides maximum 480G line cards to satisfy the increased demand for bandwidth.

 

 Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing UnitHuawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing UnitHuawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing UnitHuawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing UnitHuawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

 

The NE40E series includes the NE40E-X16A/X16, NE40E-X8A/X8, and NE40E-X3 models to satisfy requirements for networks at various scales.

Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

Product characteristics

  • Extremely large capacity line card

The NE40E can support at maximum a 480G Line Card, which fulfills the increasing network requirements of customers. The powerful 480G line card can support both 100 GE and 10 GE port types, to provide customers with flexible configurations. With excellently developed chipset technology and fine design techniques, the NE40E provides sustainable high bandwidth capacity for the future.

  • Energy saving design

The NE40E uses Huawei-developed Solar chips, which are reliable and secure. It can dynamically allocate and manage multi-core NP resources and automatically disable redundant or unused ports, buses, and chips. The NE40E also supports dynamic frequency adjustment and intelligent fan speed adjustment, which significantly reduces power consumption, with less than 1W for each gigabit, the lowest in the industry.

  • Future-oriented IPv6-compatible solutions

The NE40E supports a variety of IPv6 features including IPv6 leased line, dual stack, tunneling, and translation. The NE40E supports Next-Hop Separation to optimize the IPv6 convergence time and supports larger IPv6 FIB and CGN cards of 160G throughput to improve the scalability. These help to provide comprehensive solutions for high performance in transition from IPv6 to IPv4 and allow each provider to determine their transition strategy most suitable for their own network.

  • All-round reliability solution

The NE40E provides reliability protection at different levels, including the equipment, network, and service levels. The NE40E can provide a multi-level reliability solution that completely meets the reliability requirements of different services. The NE40E lays the foundation for enterprise services with a system availability of 99.999%.

The following describes the reliability protection levels that the NE40E provides:

  • Equipment-level reliability

The NE40E provides redundancy backup for key components. These key components support hot swapping and hot backup. The NE40E also uses technologies, such as Non-Stop Routing (NSR), Non-Stop Forwarding (NSF), and In-Service Software Upgrade (ISSU), to ensure uninterrupted service forwarding. The NE40E supports packet buffering of 200 ms, ensuring no packet loss in the case of traffic bursts — guaranteeing high-quality service experience for users.

  • Network-level reliability

The NE40E uses the following technologies to provide network-level reliability: IP Fast Reroute (FRR), Label Distribution Protocol (LDP) FRR, VPN FRR, TE FRR, hot standby, fast convergence of Interior Gateway Protocols (IGP), BGP, and multicast routes, Virtual Router Redundancy Protocol (VRRP), Rapid Ring Protection Protocol (RRPP), trunk load balancing and backup, hardware-based Bi-directional Forwarding Detection (BFD) of 3.3 ms, MPLS OAM, Ethernet OAM, and routing protocol/port/VLAN damping. The NE40E provides an end-to-end protection with no service interruption.

  • Service-level reliability

The NE40E uses the following technologies to provide service-level reliability for L2VPNs and L3VPNs: VPN FRR, E-VRRP, VLL FRR, Ethernet OAM, Y.1731, PW redundancy, E-Trunk, and E-Automatic Protection Switching (APS) These technologies ensure stable and reliable service operation with no service interruption.

 

  Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

 

Product specifications

ItemNE40E-X16ANE40E-X16NE40E-X8ANE40E-X8NE40E-X3
Number of Slots22 slots, including 2 MPUs (1:1 backup), 4 SFUs (3+1 backup), and 16 LPUs22 slots, including 2 MPUs (1:1 backup), 4 SFUs (3+1 backup), and 16 LPUs12 slots, including 2 SRUs (1:1 backup), 2 SFUs (3+1 backup), and 8 LPUs11 slots, including 2 SRUs (1:1 backup), 1 SFUs (2+1 backup), and 8 LPUs

5 slots (for 3 LPUs and 2 MPUs)

Dimensions (W x D x H)442 mm x 650 mm x 1,778  mm (40U)442 mm x 650 mm x 1,420 mm (32U)442 mm x 650 mm x 934 mm (21U)442 mm x 650 mm x 620 mm (14 U)442 mm x 650 mm x 175 mm (DC, 4U) 442 mm x 650 mm x 220 mm (AC, 5U)
Power Consumption (in full configuration)9,040 W (480G)

4,610W (120G)

7,970W (240G)

4,770W (480G)

2,340W (120G)

4,100W (240G)

1,070W (AC)

920W (DC)

Weight (in full configuration)356 kg (480G)

246 kg (120G)

279 kg (240G)

186 kg (480G)

119 kg (120G)

136 kg (240G)

42 kg (DC)

52 kg (AC)

Interface Types

100 GE/40 GE

10 GE LAN /WAN

GE/FE OC-192c/STM-64c POS

OC-48c/STM-16c POS

OC-12c/STM-4c POS

OC-3c/STM-1c POS

Channelized STM-4

Channelized OC-3/STM-1  

OC-3c/STM-1c ATM

OC-12c/STM-4c ATM

E3/CT3 CE1/CT1 E1/T1

IPv4
  • IPv4 static routes and dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP4
  • Line rate forwarding on all interfaces in complex routing environments
  • Various IPv4-to-IPv6 transition technologies: manual tunnel, automatic tunnel, 6to4 tunnel, GRE tunnel, and ISATAP tunnel
  • IPv4 over IPv6 tunnel and IPv6 Provider Edge (6PE)
  • IPv6 static routes and dynamic routing protocols, such as BGP4+, RIPng, OSPFv3, and IS-ISv6
  • IPv6 neighbor discovery, PMTU discovery, TCP6, ping IPv6, tracert IPv6, socket IPv6, static IPv6 DNS, IPv6 DNS server, TFTP IPv6 client, and IPv6 policy-based routing
  • Internet Control Message Protocol Version 6 (ICMPv6) Management Information Base (MIB), User Datagram Protocol Version 6 (UDP6) MIB, TCP6 MIB, and IPv6 MIB
  • L2NAT, NAT444, DS-Lite, and NAT64
  • MPLS TE, P2MP TE/mLDP, and MPLS/BGP VPN, in compliance with RFC 2547
  • Three inter-AS implementations, integrated with Internet services
  • Martini and Kompella MPLS L2VPN, L2VPN techniques such as VPLS and VLL, and IP interworking over heterogeneous media
  • Multicast VPN
  • MPLS TP
IPv6
MPLS
Layer 2 Features
  • IEEE 802.1Q, IEEE802.1ad, IEEE 802.1D, IEEE 802.1w, and IEEE 802.1s
  • VLAN aggregation (super VLAN)
  • 1483B and filtering list based on MAC addresses and ports
Reliability
  • IP/LDP/VPN/TE/VLL FRR, and IP/TE auto re-routing
  • IGP/BGP/ multicast route convergence, VRRP, RRPP, and IP trunk load balancing and backup
  • Hardware-based BFD of 3.3 ms, MPLS/Ethernet OAM, Y.1731, and routing protocol/port/VLAN damping
  • PW redundancy, E-Trunk, E-APS, and E-STP
  • In-service patching for smooth software upgrade
  • Passive backplane design: backup for key components such as route processing
  • IP/LDP/VPN/TE/VLL FRR, and IP/TE auto rerouting
  • IGP/BGP/multicast route convergence, VRRP, RRPP, and IP trunk load balancing and backup
  • Hardware-based BFD of 3.3 ms, MPLS/Ethernet OAM, Y.1731, and routing protocol/port/VLAN damping
  • PW redundancy, E-Trunk, E-APS, and E-STP
  • In-service patching for smooth software upgrade
  • Passive backplane design: backup for key components such as route processing modules, SFUs, and power modules to guard against single points of failure
  • Switching between components that hot back up each other, Graceful Restart (GR), NSF, NSR, and ISSU
  • Hot swap of all components
  • Well-designed HQoS and advanced scheduling and congestion avoidance technologies on each LPU
  • Accurate traffic policing and traffic shaping
  • Complex rule definition and fine-grained flow identification
  • MPLS HQoS, ensuring QoS for MPLS VPN, VLL, and PWE3 services
  • DS-TE that combines MPLS TE and the DiffServ model and 8CT
  • TE-tunnel-oriented QoS Y.1731, IP FPM, RFC 2544, MPLS OAM, 802.1ag, and 802.3ah
  • IGMPv1, IGMPv2, and IGMPv3
  • Static multicast and multicast protocols, including PIM-DM, PIM-SM, PIM-SSM, Multicast Source Discovery Protocol (MSDP), and Multiprotocol BGP (MBGP)
  • Multicast CAC
  • Interoperability between multicast protocols
  • Processing of multicast policies (multicast routing protocols and multicast forwarding policies), multicast QoS, and multicast replication for IPoE access users
  • Two-level multicast replication on the SFUs and LPUs to optimize the multicast effect
  • ACL-based packet filtering
  • URPF
  • GTSM
  • DHCP snooping
  • ARP attack defense and DoS attack defense
  • MAC address limit and MAC-IP binding
  • Secure Shell (SSH) and SSHv2
  • IPsec tunnel
  • Distributed GRE tunnel
  • Distributed NetStream
  • High-precision NAT: CGN
  • Long-term operating temperature: 0°C to 45°C
  • Short-term operating temperature: –5°C to +55°C
  • Long-term operating humidity: 5% RH to 85% RH
  • Short-term operating humidity: 0% RH to 100% RH
  • Operating altitude: ≤ 3,000 meters
QoS
OAM
Multicast
Security
Value-added Services
Environment Requirements

 

 Huawei NE40E boards List:

 

Board Name for Order Full Name
CR5B0BKP1670 NE40E-X16 Integrated Chassis Components
CR5D0MPUB460 Main Processing Unit
CR5DSFUIE07B Switch Fabric Unit
CR5DSFUI407B Switch Fabric Unit
CR5M000PEM60 DC Power Supply System
CR5B0PWRBX60 AC Power Supply System
CR5M000CMU60 Centralized Monitor Unit
CR5M000FBX60 Fan Module
- Air Filter
CR5B0BKP0870 NE40E-X8 Integrated Chassis Components
CR5D0SRUA770 Switch and Route Processing Unit A7
CR5D0SRUA570 Switch and Route Processing Unit A5
CR5D0SRUA470 Switch and Route Processing Unit A4
CR5DSFUI407C 40Gbps Switch Fabric Unit C
CR5DSFUIA07D 100Gbps Switch Fabric Unit D(SFUI-100-D)
CR5DSFUIE07C 200Gbps Switch Fabric Unit C(SFUI-200-C)
CR5M000PEM60 DC Power Supply System
CR5B0PWRBX60 AC Power Supply System
CR5M000CMU60 Centralized Monitor Unit
CR5M000FBX60 Fan Module
– Air Filter
CR5Z1BKPE NE40E-X3 Integrated DC Chassis Components
CR5Z2BKPE NE40E-X3 Integrated AC Chassis Components
CR5D0MPUD170 Main Processing Unit D2
CR5D0MPUD270 Main Processing Unit D3
CR52-PEMA DC Power Supply System
CR52-PWRD-AC AC Power Supply System
– Air Filter
CR5M000CMU60 Centralized Monitor Unit
CR52-BKPB-20U NE40E-8 Integrated Chassis Components
CR52-SRUA1 Switch and Route Processing Unit
CR52-SRUA3 Switch and Route Processing Unit
CR52-SFUD Switch Fabric Unit
CR52-PWRB DC Power Supply Module
CR52-PWRC AC Power Supply Module
– Air Filter
CR5M000CMU60 Centralized Monitor Unit

CR53-SPU-C Versatile Service Process Unit C
CR5MVSUF1010 Flexible Card Versatile Service Unit 10(VSUF-10)
CR5DVSUI201A Integrated Versatile Service Unit 20 A (VSUI-20-A)
CR5DVSUFD010 Flexible Card Versatile Service Unit 160(VSUF-160)
CR5DVSUF8010 Flexible Card Versatile Service Unit 80(VSUF-80)
CR5D00SNCA70 Flexible Card SNC Service Unit A(SNC-A)
CR5D00SPD010 Versatile Service Flexible Card(SP160)
CR5D00SP8010 Versatile Service Flexible Card(SP80)
CR53-LPUF-10 Flexible Card Line Processing Unit (LPUF-10,four slots)
CR53-P10-1xPOS/STM64-XFP 1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots)
CR53-P10-1xPOS/STM16-SFP 1-Port OC-48c/STM-16c POS-SFP Flexible Card
CR53-P10-2xPOS/STM16-SFP 2-Port OC-48c/STM-16c POS-SFP Flexible Card
CR53-P10-4xPOS/STM16-SFP 4-Port OC-48c/STM-16c POS-SFP Flexible Card
CR53-P10-4xPOS/STM4-SFP 4-Port OC-12c/STM-4c POS-SFP Flexible Card
CR53-P10-8xPOS/STM4-SFP 8-Port OC-12c/STM-4c POS-SFP Flexible Card
CR53-P10-4xPOS/STM1-SFP 4-Port OC-3c/STM-1c POS-SFP Flexible Card
CR53-P10-8xPOS/STM1-SFP 8-Port OC-3c/STM-1c POS-SFP Flexible Card
CR53-P10-2xATM/STM4-SFP 2-Port OC-12c/STM-4c ATM-SFP Flexible Card
CR53-P10-4xATM/STM1-SFP 4-Port OC-3c/STM-1c ATM-SFP Flexible Card
CR53-P10-8x100/1000Base-X-SFP 8-Port 100/1000Base-X-SFP Flexible Card
CR5M0E8GFA30 8-Port 100/1000 Base-X-SFP Flexible Card A (Supporting 1588v2)
CR53-P10-2xcPOS/STM1-SFP 2-Port Channelized OC-3c/STM-1c POS-SFP Flexible Card
CR53-P10-24xcE1/cT1-DB100 24-Port Channelized E1/T1-DB100 Flexible Card
CR53-P10-4xE3/cT3-SMB 4-Port Clear Channel E3/Channelized T3-SMB Flexible Card
CR52-LPUF-21-A Flexible Card Line Processing Unit(LPUF-21-A/LPUF-21-B/LPUF-21-E,2 sub-slots)
CR52-LPUF-21-B
CR5DLPUF202E
CR52-P20-1x10GBase WAN/LAN-XFP 1-Port 10GBase WAN/LAN-XFP Flexible Card
CR52-P20-1x10GBase WAN/LAN-XFP-A 1-Port 10GBase WAN/LAN-XFP Flexible Card A(Supporting 1588v2)
CR5M0L1XXB20 1-Port 10GBase LAN/WAN-XFP Flexible Card B(P20-B)
CR5M0L1XXE20 1-Port 10GBase LAN/WAN-XFP Flexible Card E(P20-E)
CR52-P20-12x100/1000Base-X-SFP 12-Port 100/1000Base-SFP Flexible Card
CR52-P20-12x100/1000Base-X-SFP-A 12-Port 100/1000Base-SFP Flexible Card A(Supporting 1588v2)
CR52-P20-12x10/100/1000Base-TX-RJ45 12-Port 10/100/1000Base-RJ45 Flexible Card
CR5M0EBGFB20 12-Port 100/1000Base-X-SFP Flexible Card B(P20-B)
CR5M0EAGFE20 10-Port 1000Base-X-SFP Flexible Card E(P20-E)
CR52-P20-1xPOS/STM64-XFP 1-Port OC-192c/STM-64c POS-XFP Flexible Card
CR52-P21-4x10GBase WAN/LAN-XFP 4-Port 10GBase WAN/LAN-XFP Flexible Card(Occupy two sub-slots)
CR52-P21-40x10/100/1000Base-TX-RJ45 40-Port 10/100/1000Base-RJ45 Flexible Card(Occupy two sub-slots)
CR52-P21-40x100/1000Base-X-SFP 40-Port 100/1000Base-SFP Flexible Card(Occupy two sub-slots)
CR5ML2XEEG20 2-Port 10GBase LAN/WAN-XFP+20-Port 100/1000Base-X-SFP Flexible Card(P20,Occupy two sub-slots)
CR5D00L4XX21 4-Port 10GBase WAN/LAN-XFP Line Processing Unit S(LPUS-20)
CR5D00EKGF21 40-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-20)
CR5D00EKGE20 40-Port 10/100/1000Base-RJ45 Line Processing Unit S
CR5D0EFGFA73 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-21-L)
CR5DL1XEDG70 1-Port 10GBase LAN/WAN-SFP+ + 16-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-21-L)
CR5MLPUF402A Flexible Card Line Processing Unit(LPUF-40-A/LPUF-40-B/LPUF-40-E,2 sub-slots)
CR5MLPUF402B
CR5DLPUF402E
CR5M00EEGF20 20-Port 100/1000Base-X-SFP Flexible Card(P40)
CR5M0EEGFA20 20-Port 100/1000Base-X-SFP Flexible Card A(P40-A,Supporting 1588v2)
CR5M0EEGFB20 20-Port 100/1000Base-X-SFP Flexible Card B(P40-B)
CR5M0L2XXA20 2-Port 10GBase LAN/WAN-XFP Flexible Card B(P40-B)
CR5M00L2XX20 2-Port 10GBase LAN/WAN-XFP Flexible Card(P40)
CR5M0L2XXA20 2-Port 10GBase LAN/WAN-XFP Flexible Card A(Supporting 1588v2)
CR5D0EEGFE70 20-Port 1000Base-X-SFP Flexible Card E(P40-E)
CR5D0L2XXE70 2-Port 10GBase LAN/WAN-XFP Flexible Card E(P40-E)
CR5D00EEGE70 20-Port 10/100/1000Base-RJ45 Flexible Card(P40)
CR5D00L4XX70 4-Port 10GBase LAN/WAN-XFP Flexible Card(P40,Occupy one sub-slot)
CR5D00EKGF20 40-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-40)
CR5D00L4XX20 4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit(LPUI-40)
CR5D00L8XX70 8-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41)
CR5D00L4XX71 4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41)
CR5D00EMGF70 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41)
CR5DL2XEFG70 2-Port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41)
CR5D0L4XXA70 4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)
CR5D0EKGFA70 40-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41,Supporting 1588v2)
CR5DL2XEEG7A 2-Port 10GBase LAN/WAN-XFP+20-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41,Supporting 1588v2)
CR5D00L8XX71 8-Port 10GBase LAN/WAN-XFP Line Processing Unit S (LPUS-41)
CR5D00L4XX72 4-Port 10GBase LAN/WAN-XFP Line Processing Unit S (LPUS-41)
CR5D00EMGF71 48-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-41)
CR5DL2XEFG71 2-Port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-41)
CR5DLPUF5070 Flexible Card Line Processing Unit(LPUF-50,four sub-slots)
CR53-P10-24xcE1/cT1-DB100 24-Port Channelized E1/T1-DB100 Flexible Card
CR53-P10-8xPOS/STM1-SFP 8-Port OC-3c/STM-1c POS-SFP Flexible Card
CR53-P10-4xPOS/STM16-SFP 4-Port OC-48c/STM-16c POS-SFP Flexible Card
CR53-P10-2xPOS/STM16-SFP 2-Port OC-48c/STM-16c POS-SFP Flexible Card
CR53-P10-2xcPOS/STM1-SFP 2-Port Channelized OC-3c/STM-1c POS-SFP Flexible Card
CR53-P10-8xPOS/STM4-SFP 8-Port OC-12c/STM-4c POS-SFP Flexible Card
CR5M0E8GFA30 8-Port 100/1000 Base-X-SFP Flexible Card A (Supporting 1588v2)
CR5D0L2XFA70 2-Port 10GBase WAN/LAN-SFP+ Flexible Card A
CR53-P10-1xPOS/STM64-XFP 1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots)
CR5D00C4CF70 4-Port Channelized STM-1c POS-SFP Flexible Card
CR5D00C8CF71 8-Port Channelized STM-1c POS-SFP Flexible Card
CR5D00A8CF70 8-Port OC-3c/STM-1c ATM-SFP Flexible Card(P50)
CR5D00MD8A70 8-Channel CWDM Multiplexing & Demultiplexing (1471/1491/1511/1531/1551/1571/1591/1611nm) Flexible Card (P50)
CR5D0L1XFA70 1-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P50-A)
CR5M00C1HF50 1-Port Channelized STM-4 POS-SFP Flexible Card (P50)
CR5DLPUF5170 Flexible Card Line Processing Unit(LPUF-51/LPUF-51-B/LPUF-51-E,two sub-slots)
CR5DLPUF517B
CR5DLPUF517E
CR5D0EFGFA70 24-Port 100/1000Base-X-SFP Flexible Card A(P51-A)
CR5D0L5XFA70 5-Port 10GBase LAN/WAN-SFP+Flexible Card A (P51-A, Occupy two sub-slots)
CR5D0L2XFA71 2-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P51-A)
CR5D0EFGFE70 24-Port 1000Base-X-SFP Flexible Card E(P51-E)
CR5D0L5XFE70 5-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P51-E, Occupy two slots)
CR5D0L2XFE70 2-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P51-E)
CR5D0EEGEA70 20-Port 10/100/1000Base-RJ45 Flexible Card(P51-A)
CR5D0L2XFH70 2-Port 10GBase LAN/WAN-SFP+ Flexible Card H(P51-H)
CR5D0L5XFA71 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-51)
CR5D0L4XFA70 4-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-51)
CR5D0EMGFA70 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51)
CR5DL2XEFG7A 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51)
CR5DL4XEBG7C 4-Port 10GBase LAN/WAN-SFP+ + 12-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51)
CR5D0L5XFA7B 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-51-B)
CR5D0L4XFA7B 4-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-51-B)
CR5D0EMGFA7B 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit B(LPUI-51-B)
CR5DL2XEFG7B 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit B(LPUI-51-B)
CR5D0L5XFA7L 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit L(LPUI-51-L)
CR5D0EMGFA7L 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-51-L)
CR5DL2XEIG7L 2-Port 10GBase LAN/WAN-SFP+ + 32-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-51-L)
CR5D0L5XFA7E 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit E(LPUI-51-E,Enhanced HQos)
CR5DL2XEFG7E 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 1000Base-X-SFP Integrated Line Processing Unit E(LPUI-51-E,Enhanced HQos)
CR5DL4XEBG7L 4-Port 10GBase LAN/WAN-SFP+ + 12-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-51-L)
CR5D0L5XFA7J 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit E(LPUI-51-E)
CR5DL2XEFG7J 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit E(LPUI-51-E)
CR5D0EMGFA7J 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit E(LPUI-51-E)
CR5D0L2XFH70 2-Port 10GBase LAN/WAN-SFP+ Flexible Card H(P51-H)
CR5DL3XEFG7C 3-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51-E)
CR5D00L5XF72 5-Port 10GBase LAN/WAN-SFP+ Line Processing Unit S(LPUS-51)
CR5D00L4XF71 4-Port 10GBase LAN/WAN-SFP+ Line Processing Unit S(LPUS-51)
CR5D00EMGF73 48-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-51)
CR5DL2XEFG72 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-51)
CR5DLPUFA070 Flexible Card Line Processing Unit(LPUF-100,four slots)
CR5D0L5XXA70 5-Port 10GBase LAN/WAN-XFP Flexible Card A(P100-A,Supporting 1588v2,Occupy two sub-slots)
CR5D00EFGF70 24-Port 100/1000Base-SFP Flexible Card(P100,Occupy two sub-slots)
CR5D00EMGF72 48-Port 100/1000Base-X-CSFP Flexible Card(P100,Occupy two sub-slots)
CR5D00P1MZ70 1-Port OC-768c/STM-256c POS-2KM-LC Flexible Card(P100,Occupy two sub-slots)
CR5D00P2XX70 2-Port OC-192c/STM-64c POS-XFP Flexible Card (P101-A,Occupy one sub-slots)
CR5D0LAXXA70 10-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit(LPUI-100,Supporting 1588v2)
CR5D00EDXF70 16-Port 10GBase LAN-SFP+ Integrated Line Processing Unit(LPUI-100)
CR5D00E1NC70 1-Port 100GBase-CFP Integrated Line Process Unit(LPUI-100)
CR5D00LAXX71 10-Port 10GBase LAN/WAN-XFP Line Processing Unit S(LPUS-100)
CR5D00EDXF71 16-Port 10GBase LAN-SFP+ Line Processing Unit S(LPUS-100)
CR5D00E1NC71 1-Port 100GBase-CFP Line Processing Unit S (LPUS-100)
CR5D0L5XXA70 5-Port 10GBase LAN/WAN-XFP Flexible Card A(P100-A,Supporting 1588v2,Occupy two sub-slots)
CR5DLPUFA071 Flexible Card Line Processing Unit (LPUF-101/LPUF-101-B)
CR5DLPUFA07B
CR5D0EFGFA71 24-Port 100/1000Base-X-SFP Flexible Card A(P101-A)
CR5D0L5XFA72 5-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P101-A)
CR5D00E1MC70 1-Port 40GBase LAN-CFP Flexible Card A(P101-A)
CR5D0L5XFE71 5-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P101-E)
CR5D0EFGFE70 24-Port 1000Base-X-SFP Flexible Card E(P51-E)
CR5D00E2MC70 2-Port 40GBase LAN-CFP Integrated Line Processing Unit (LPUI-101)
CR5D00E1NC72 1-Port 100GBase-CFP Integrated Line Processing Unit (LPUI-101)
CR5D0LAXFA71 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-101)
CR5D00E2MC7B 2-Port 40GBase LAN-CFP Integrated Line Processing Unit B(LPUI-101-B)
CR5D0LAXFA7B 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-101-B)
CR5D00E2MC71 2-Port 40GBase LAN-CFP Line Processing Unit S(LPUS-101)
CR5D00E1NC73 1-Port 100GBase-CFP Line Processing Unit S(LPUS-101)
CR5D0LAXFA72 10-Port 10GBase LAN/WAN-SFP+ Line Processing Unit S(LPUS-101)
CR5DLAXFAJ7E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit E(LPUI-102-E)
CR5DLPUFB070 Flexible Card Line Processing Unit(LPUF-120/LPUF-120-B/LPUF-120-E)
CR5DLPUFB07B
CR5DLPUFB07E
CR5D0L6XFA70 6-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P120-A)
CR5D00E1NC75 1-Port 100GBase-CFP Flexible Card A(P120-A)
CR5D00LBXF72 12-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P120-A)
CR5D0EFGFA71 24-Port 100/1000Base-X-SFP Flexible Card A(P101-A)
CR5D0L5XFA72 5-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P101-A)
CR5D00E1MC70 1-Port 40GBase LAN-CFP Flexible Card A(P101-A)
CR5D0L5XFE71 5-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P101-E)
CR5D0EFGFE70 24-Port 1000Base-X-SFP Flexible Card E(P51-E)
CR5D0L5XFH70 5-Port 10GBase LAN/WAN-SFP+ Flexible Card H(P120-H)
CR5D00T6XF70 6-Port OTU2-SFP+ Flexible Card(P120)
CR5D00TBXF70 12-Port OTU2-SFP+ Flexible Card (P240)
CR5D0LBXFA70 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit(LPUI-120)
CR5D0E2MCA70 2-Port 40GBase LAN-CFP Integrated Line Processing Unit(LPUI-120)
CR5D00E1NC76 1-Port 100GBase-CFP Integrated Line Processing Unit (LPUI-120)
CR5D0LBXFA7B 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-120-B)
CR5D0E2MCA7B 2-Port 40GBase LAN-CFP Integrated Line Processing Unit B(LPUI-120-B)
CR5D00E1NC7B 1-Port 100GBase-CFP Integrated Line Processing Unit B (LPUI-120-B)
CR5DLPUFF070 Flexible Card Line Processing Unit(LPUF-240/LPUF-240-B/LPUF-240-E)
CR5DLPUFF07B
CR5D00E1NC74 1-Port 100GBase-CFP Flexible Card A(P240-A)
CR5D00LBXF71 12-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P240-A)
CR5D0LAXFE70 10-Port 10GBase LAN/WAN-SFP+ Flexible Card E (P240-E)
CR5D00LAXF70 10-Port 10GBase LAN/WAN-SFP+ Flexible Card A (P240-A)
CR5D0E3MFA70 3-Port 40GBase-QSFP+ Flexible Card(P240-A)
CR5D00TBXF70 12-Port OTU2-SFP+ Flexible Card (P240)
CR5D0LAXFH70 10-Port 10GBase LAN/WAN-SFP+ Flexible Card H (P240-H)
CR5D00E2NC70 2-Port 100GBase-CFP Integrated Line Processing Unit (LPUI-240)
CR5D00LFXF70 24-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing
CR5DE2NLBX70 1-Port 100GBase-CFP + 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-240)
CR5D00E2NC73 2-Port 100GBase LAN-CFP Integrated Line Processing Unit B(LPUI-240-B)
CR5D00LFXF73 24-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-240-B)
CR5DE2NLBX73 1-Port 100GBase-CFP + 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-240-B)
CR5D0E6MFA70 6-Port 40GBase-QSFP+ Integrated Line Processing Unit (LPUI-240)
CR5D0E6MFA71 6-Port 40GBase-QSFP+ Integrated Line Processing Unit (LPUI-240-B)

 

 

  Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

 

  Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

 

Photos:


  Huawei CR5DLAXFAJ7E 03054627 LPUI-102-E 10x10GBase LAN/WAN-SFP+ -E 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit

Contact Supplier

Hsu Chiao Hsin Chat Now
Telephone
54-911-58030666
Address
Av. Corrientes 3953, C1194AAF

You May Like

New Products

Find Similar Products By Category

Consumer Electronics > Computer Hardware & Software > Routers
Categories
Hi~