Battery replacement ultrasonic thickness gauge meter tester physical measuring instruments
USD $1 - $300 /Set
Min.Order:1 Set
Hangzhou Pulani Electronic Technology Co., Ltd.
Coating thickness measuring meter gauge which have the statistics data function
with fe and nfe probe 2 in 1 coating thickness measuring meter
Steel ultrasonic physical thickness gauge meter tester measuring instruments
Current conductivity meter with Unique temperature coefficient set and design eddy
Battery replacement ultrasonic thickness gauge meter tester physical measuring instruments
Introducton & Application:
Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc. in industries of petroleum, shipbuilding, power station, and machine manufacturing. Materials measured: only 11 types of materials, including steel, cast iron, aluminum, red copper, brass, zinc, quartz glass, polyethylene, PVC, gray cast iron, nodular cast iron.
Specifications:
Display: | 4.5 digits LCD with EL backlight |
Operating principle: | ULTROSONIC |
Measuring range (metric/imperial): | 1.0 - 200mm,0.05-8inch (in Steel) |
Resolution: | 0.1mm |
Accuracy: | ±(0.5%H+0.1)mm, depends on materials and conditions |
Units: | Metric/Imperial unit selectable |
Power supply: | 4x1.5 AAA size (UM-4) battery 1 |
Battery indicator: | low battery indicator |
Operating conditions: | 0-+45°C(32°F-104°F),≤90%RH |
Standard Delivery: | Main Unit, 8mm Probe, Coupling Oil, User Manual, Carrying Case |
Functions:
High resolution measurement
Probe automatic zero calibration for system error correction
Capture the value of the minimum thickness.
Status indicator of the coupling and low battery.
Auto sleep and auto power off function to conserve battery life.
Humanized shape design, compact and portable, Can be used in harsh environment.
Notes:
1. When big difference occurred,p lease check as below:
1.1If the material code is correct;
1.2Re-calibration;
1.3There are air hole, Non-smooth inside material.
2. Please don't pull the wire of sensor often to avoid the wire broken or with bad contact ion.
3. Keep the sensor clean when finished testing.
4. Only can calibration on standard calibrate block,other test block will result in big error or wrong value in our calibration method 5.
5. Don’t repair by yourself. Non-authrised repair method not only cause of the error measurement, but also lose the warranty right.
Thanks for your attention to our products, any interest pls contact Ms.Shelley, and wish you have a nice day.