Leopard 3 type alcohol detector electrochemical civil Alcohol Tester GF-KY-8300
USD $125.00 - $125.00 /Piece
Min.Order:3 Pieces
GoldFly Technology Company Limited
Detailed Introduction
With fuel cell based and designed for personal use, KY-8300 is a handheld instrument preliminarily to determine a subject's breath alcohol level quickly and precisely.
Specifications
1. Quick and Precise Analysis: 32-bit embedded processor secures high performance of the system.
2. UK made Electrochemical/Fuel cell Sensor: Highly specificity to alcohol, unaffected by other possible breath contaminants.
3. Data Handling Ability: Compact gas circuit design and advanced analysis process assure fast, accurate and stable testing performance.
4. Active and Passive Blow Methods: Both methods can be applied to provide convenience to the user.
5. Power Supply: Built-in Li-ion battery realises reliable and long-time testing action.
6. Memory Capacity: Data storage of 4096 test results. Any test results can be downloaded to the computer for data backup.
7 After Sales Service: Independent intellectual property rights integrated with research, development and production ability guarantee strong after-sales service.
Details | Technical data | ||
Principle of measurements | Electrochemical/fuel cell sensor, alcohol specific | ||
Measurement range (BrAC) | 0.000mg/L~1.500mg/L | ||
Resolution | 0.0001 mg/L | ||
Accuracy: Max. Measure error, in relation to ethanol standard | Ethanol Vapor Concentration C /(mg/L) | Deviation | |
C<0.400 | ±0.020mg/L | ||
0.400≤C<1.000 | ±5% | ||
C≥1.000 | ±20% | ||
Repeatability of Indicating Value | Ethanol Vapor Concentration C /(mg/L) | Deviation | |
C<0.400 | 0.007mg/L | ||
0.400≤C<1.000 | 1.75% | ||
C≥1.000 | 6% | ||
Calibration | Every 6 months | ||
Temperature Range-Operation | -10℃~45℃ | ||
Temperature Range-Storage | -20℃~70℃ | ||
Optimum Storage Condition | Temperature 20℃±5, Humidity: <80%RH, Pressure: 86kPa~106kPa, No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device. | ||
Blowing Time | 2.5 seconds (breath flow≥20L/min) | ||
Warm-up Time | Less than 5 seconds after switching on | ||
Recovery Time | 5 seconds to 5 minutes, depends on Ethanol Vapor Concentration | ||
Analysis Time | Less than 10 seconds | ||
Display | 128×64 dot matrix black and white screen | ||
Dimensions | Approx. 127mm×60mm×28mm | ||
Memory | 4096 records | ||
Operation Voltage | State of Charging | State of Operation | |
5 V | DC 3.6~4.2V | ||
Battery | Built-in 1000mAh/3.7V Li-ion polymerized battery | ||
Weight | Approx. 115g (including batteries) |