High Static Pressure Duct Unit air conditioning diffuser
High Static Pressure Duct Unit air conditioning diffuser
High Static Pressure Duct Unit air conditioning diffuser
High Static Pressure Duct Unit air conditioning diffuser
High Static Pressure Duct Unit air conditioning diffuser
High Static Pressure Duct Unit air conditioning diffuser

High Static Pressure Duct Unit air conditioning diffuser

Negotiable /Set

Min.Order:1 Set

Supply Ability:
300 Set / Sets per Month
Port:
shenzhen
Payment Terms:
T/T

Quick Details View All >

Condition:
New
Place of Origin:
Guangdong, China
Brand Name:
Hicool
Model Number:
H-DHR140
Voltage:
380V
Power(W):
4.8KW

Huizhou Hicool Climate Equipment Co., Ltd.

Business Type: Manufacturer
Huizhou Guangdong China
Main Products: Rooftop packaged unit ,water cooled packaged heat pump ,ground source heat pump ,chiller ,air source heat pump

Product Details

Specifications

Cooling capacity: 10.6~30kW, heating capacity: 12.8~33kW
Power supply: outdoor unit: 220V, 1p, 50/60Hz or 380V, 3p, 50/60Hz

1. Air cooled air-air air conditioning system saves investment:
High static pressure duct unit is split type air-air air conditioning system equipment, it has no request on water system & compound equipments, can reduce initial investment, can implement cooling & heat pump function simply & highly efficiently.
2. Flexible application, air flow speed can be adjusted at will
High static pressure design, air flow can be conveyed through long distance, operation can be adjusted at high/medium/low speed freely, flexible installation, can meet all kinds of customer request.
3. Excellent performance, running silently

The unit adopts world famous brand scroll compressor, configured with high efficiency low noise vibration absorption fan special for air conditioner, which has excellent air supply performance, running silently.
4. Graceful & magnificent decoration
Decorated as central air conditioners, indoor units & duct is installed in the ceiling, only the air outlets will be the exposed components, which can be blended into all kinds of decoration smoothly, makes people feel convenient & graceful.
Application range
The units have excellent performance, can be freely applied & easily installed, can meet all kinds of requirements for home, industrial & commercial use, widely used in buildings like emporiums, hotels, supermarkets, workshops, residential houses, apartments, etc.

 

 


High Static Pressure Duct Unit Parameter
 
 ModelH-DhR100SH-DhR140SH-DhR180TH-DhR180T/3H-DhR220T/3H-DhR260T/3H-DhR300T/3
 Cooling CapacitykW10.614.218.418.522.226.530
 Heating CapacitykW12.816.520.521.524.528.633

Rated Input Power
 CoolingkW3.34.55.85.878.310.6
 HeatingkW3.95.26.46.67.58.611.2

Rated Input Current
CoolingA18.725.5331113.315.816
 HeatingA2229.53612.514.216.317
 Indoor Unit
 Power Supply 220V~ /1Ph/ 50Hz 
 Rated Air Flow Volumem3/h1800260035003500400048006000
Fan Motor PowerkW0.150.2750.15×20.15×20.25×20.375×20.55×2
 Fan Motor Input CurrentA1.362.52.722.724.56.84.8
Static PressurePa70-130
 NoisedB(A)51545555565758

Net Dimension(LxWxH)
mm1050×600×4351050×600×4351350×600×4351350×600×4351600×600×4351600×600×4351900×800×540
 Net Weight kg495972738484110

Packing Dimension(LxWxH)
mm1090×658×4951090×658×4951390×658×4951390×658×4951640×658×4951640×658×4951950×850×600
Gross Weight kg536377789191118
Outdoor Unit
 Power Supply 220V~ /1Ph/50Hz 380V~ /3Ph/ 50Hz
 Refrigerant Chargekg23.24.54.24.556
 RefrigerantR22 

Connecting Pipe
 LiquidInches3/8"1/2"1/2"1/2"1/2"5/8"2x1/2"
 GasInches5/8"3/4"3/4"3/4"3/4"7/8"2x3/4"

Maximum Piping Length
m50

Maximum Height Drop
m30
 Air Discharging Type Side Top
 NoisedB(A)57596161636365

Net Dimension(LxWxH)
mm1010×416×8651010×416×12801100×640×10101100×640×10101250×640×10101250×640×10101650×790×1040
 Net Weight kg80128165140150180260

Packing Dimension(LxWxH)
mm1110×462×10801110×462×14951146×735×11101146×735×11101296×735×11101296×735×11101700×890×1140
 Gross Weight kg85132203178188220310

Note:
1)Nominal cooling conditions: indoor dry bulb temperature is 27
°C, indoor wet bulb temperature is 19°C, outdoor dry bulb temperature is 35°C, outdoor wet bulb temperature is 24°C.
2)Nominal heating conditions: indoor dry bulb temperature is 20
°C, indoor wet bulb temperature is 15°C, outdoor bulb temperature is 7°C, outdoor wet bulb temperature is 6°C.

 

 

 High Static Pressure Duct Unit air conditioning diffuserHigh Static Pressure Duct Unit air conditioning diffuserHigh Static Pressure Duct Unit air conditioning diffuserHigh Static Pressure Duct Unit air conditioning diffuserHigh Static Pressure Duct Unit air conditioning diffuserHigh Static Pressure Duct Unit air conditioning diffuser

Contact Supplier

Ms. Jessie Li Director Chat Now
Telephone
86-0752-3619816
Mobile
13600105055
Fax
86-0752-2100391
Address
Xinhu Development Zone, Ma'an Huizhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Energy & Mineral Equipment > Energy Saving Equipment
Categories
Hi~