Metal standalone controller support dual card
USD $30 - $35 /Piece
Min.Order:1 Piece
Shenzhen Crypton Electronic Co., Ltd.
Standalone Access Controller and Reader M2
1 Description& Features:
1.1 Description:
M2 is a waterproof standalone access control, reading EM&HID card, it uses advanced Microprocessor, with high-capacity flash memory for 10000 users. Users can be added and deleted via admin card, very simple to operate. The infrared remote control make the device not only have alarm, protection, two units interlocked, anti-passback function but also can make two units interlocked, add and delete the user on the remote control key directly.
Besides, it has low power consumption design, anti-theft alarm, door release button ect. , all these make it convenient, safe and reliable.
1.2 Features:
Feature | Description |
Waterproof Design | Rainproof, moistureproof , durable |
Ultralow power consumption | Longer working life, more stable performance |
Large capacity | 10000 card users |
wiegand reader | Can used as wiegand 26 output reader |
Connect external reader | Can connect EM/IC/HIDwiegand 26 output reader |
two units interlocked | two units can be interlocked online |
Anti-passback | Single door or two doors anti-passback |
2 Installation, wiring, diagram
2.1 Installation:
2.1.1 Drill the holes according to the distance and the dimension on the back cover, or install the distributing box.
2.1.2 Thread the cable through the cable hole, connect wires needed, wrapped Unused wires with insulating tape in case of short circuit
2.1.3 Fix the back cover on the wall with special screw
2.1.4 Fix the front cover to the back cover with the screws
2.2 Wiring
No. | Marks | Color | Description |
1 | RESET | Pink | RESET |
2 | GND | Pink | RESET |
3 | D0 | Green | Wiegand output D0 |
4 | D1 | White | Wiegand output D1 |
5 | ALARM- | Gray | Alarm |
6 | OPEN | Yellow | Exit button |
7 | D_IN | Brown | Door contact switch |
8 | +12V | Red | +12V Input |
9 | GND | Black | GND |
10 | NO | Blue | Relay NO end |
11 | COM | Purple | Relay Com |
12 | NC | Orange | Relay NC end |
Note: Please check all wires and install front cover carefully before power on.
3 Factory Reset and Set management card
Press initialized button,then power on,and then release after sound“didi…. When indication LED turns green,
it means you can set two admin cards now,read the first card as admin add card.the second card as admin delete card,
then LED turns red flash,after this, this device can work ,resetting to factory default.
Note: Reset factory default wont delete user cards, If you present the same card when second read,
the device will sound error reminding “dididi”, then you can continue present another card. If no operations within
10seconds, the device will enter working mode automatically , parameter reset to factory default.
...