Universal Transmitter
4114
- Input for RTD,TC, Ohm, potentiometer,mA and V
- 2-Wire supply > 16V
- FM-approved for installation in Div. 2
- Output for current and voltage
- Universal AC or DC supply
Environmental Conditions
Specifications range....................................... -20°C to +60°C
Calibration temperature................................. 20...28°C
Relative humidity............................................ < 95% RH (non-cond.)
Protection degree...........................................IP20
Mechanical specifications
Dimensions (HxWxD).....................................109 x 23.5 x 104 mm
Dimensions (HxWxD) w/ 4501
/ 4511.............................................................109 x 23.5 x 116 / 131 mm
Weight approx................................................145 g
Weight incl. 4501 / 4511 (approx.).................160 g / 245 g
Wire size........................................................1 x 2.5 mm2 stranded wire
Screw terminal torque....................................0.5 Nm
Vibration.........................................................IEC 60068-2-6 : 2007
Vibration: 2...13.2 Hz.....................................±1 mm
Vibration: 13.2...100 Hz.................................±1 mm
Common specifications
Supply voltage, universal...............................21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse...............................................................400 mA SB / 250 VAC
Max. power consumption...............................≤ 2.0 W
Isolation voltage, test / working.....................2.3 kVAC / 250 VAC
Communications interface.............................
Communication enabler 4511 / Programming front 4501
Signal / noise ratio.........................................Min. 60 dB (0...100 kHz)
Response time (0...90%, 100...10%):
Temperature input..........................................≤ 1 s
Response time (0...90%, 100...10%):
mA / V input....................................................≤ 400 ms
Auxiliary supplies: 2-wire
supply (terminal 44...43)................................5...16 VDC / 0...20 mA
Accuracy........................................................Better than 0.1% of selected range
EMC immunity influence................................< ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst.................................< ±1% of span
Input specifications
RTD input......................................................Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100
Cable resistance per wire
(max.), RTD...................................................50 Ω
Sensor current, RTD......................................Nom. 0.2 mA
Effect of sensor cable resistance
(3-/4-wire), RTD.............................................< 0.002 Ω / Ω
Sensor error detection, RTD..........................yes
Short circuit detection, RTD...........................< 0.002 Ω / Ω
Linear resistance input...................................0 Ω...10000 Ω
Potentiometer input........................................10 Ω...100 kΩ
TC input: Thermocouple type.........................B, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation
(CJC) via ext. sensor in
connector 5910..............................................20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C
CJC via internally mounted sensor................±(2.0°C + 0.4°C * Δt)
Δt =.................................................................Internal temperature-ambient temperature
Sensor error detection, TC............................. yes
Sensor error current: When
detecting / else...............................................Nom. 2 μA / 0 μA
Current input: Measurement range................0...20 mA
Current input: Programmable
measurement ranges.....................................0...20 and 4...20 mA
Input resistance, current input........................Nom. 20 Ω + PTC 50 Ω
Voltage input: Measurement range.................0...12 VDC
Programmable measurement ranges, VDC....0/0.2...1, 0/1...5, 0/2...10 VDC
Input resistance, voltage input.........................Nom. 10 MΩ
Output specifications
Current output: Signal range.........................0...20 mA
Programmable current ranges.......................0...20 / 4...20 / 20...0 and 20...4 mA
Load (max.)....................................................20 mA/800 Ω/16 VDC
Load stability, current output..........................≤0.01% of span / 100 Ω
Sensor error indication, current output..........0 / 3.5 / 23 mA / none
NAMUR NE 43 Upscale/Downscale..............23 mA / 3.5 mA
Current limit....................................................≤ 28 mA
Voltage output: signal range..........................0...10 VDC
Programmable voltage ranges....................... 0/0.2...1; 0/1...5 ; 0/2...10;1...0.2/0; 5...1/0; 10...2/0 V
Load (min.).....................................................500 kΩ
*of span..........................................................= of the currently selected measurement range
Approvals
EMC...............................................................EN 61326-1
LVD 2006/95/EC............................................EN 61010-1
FM..................................................................3025177
UL...................................................................UL 508
EAC TR-CU 020/2011...................................EN 61326-1
DNV Marine....................................................Stand. f. Certific. No. 2.4
SIL.................................................................. Hardware assessed for use in SIL applications