off grid modular PV hybrid system ---off grid solar inverter 1200w-6000w
Negotiable /Unit
Min.Order:5 Units
EastWest Energy Technology Ltd.
off grid modular PV hybrid system ---off grid solar inverter 1200w-6000w
Product Photo:
Introduction:
Modular PV hybrid system can be customized combination, designed for users in area without electricity, power failure, or unstable electricity. It can be mixed with state grid, diesel, and wind turbine, prior to use new energy, to make sure the un un-interruptible power resources for the user through rational energy management.
Advantages:
High reliability
Unlike the design of controller and inverter on current market, MPHS good ventilation system ensures PV system works in high temperature environment. Modular design makes the system has redundancy, so that it can work normally when error module quits.
High flexibility
Standardized system module unit design is easy to install, maintain, and replace, and can be expand after installation. Each component is designed standardized, including module, power distribution, controller, inverter, battery, battery box, module bracket. It can be combined at will to enhance flexibility, and shorten production cycle.
High availability
Used in area without electricity, power failure, or unstable electricity, can be mixed with state grid, diesel, and wind turbine. It can be combined at will to satisfy various demands of clients.
Modular PV Hybrid System --- inverter 1.2KWp --- 6KWp
System Configuration:
System Power | 1.2KW | 1.5KW | 2.4KW | 3KW | 3.6KW | 4.5KW | 4.8KW | 6KW |
Solar Charge Controller | MPPT 40A | MPPT 60A | ||||||
Solar Module | 250Wp*4pcs | 250Wp*6pcs | 250Wp*9pcs | 250Wp*12pcs | ||||
Battery | 150Ah/12V*4pcs | 200Ah/12V*4pcs | 150Ah/12V*8pcs | 200Ah/12V*8pcs |
Inverter:
DC input voltage | 12V/24V/48V |
AC output voltage | 100V/110V/120V/220V/230V/240V |
Rated frequency | 50/60Hz(+1%) |
Max efficiency | 92%(48V)/ 91%(24V)/ 90%(12V) |
THD |
< 3% |
Crest factor | 3:1 |
No load current draw | ≤15W |
Stand-by current draw | ≤7W (power saving mode) |
Optional bypass output voltage range | 220/230/240Vac 100/110/120Vac (80%-120%) |
Charge Controller:
Deep discharge protection | 11.0V/22.0V/44.0V |
Max. input voltage (Voc) | <150V |
No load current draw | < 25mA (48V) |
Float charge | 13.7V / 27.4V / 54.8V |
Absorption charge | 14.0V / 28.0V / 56.0V |
Bulk charge | 14.4V / 28.8 V / 57.6V |
Low voltage reconnection(LVR) | 12.6V / 25.2V / 50.4V |
Low voltage disconnection (LVD) | 11.0V / 22.0V / 44.0V |
Temperature compensation | -4mV/oC/cell |
Charging efficiency | >95% |
Protection class | IP21 |
Other parameters:
Operation temperature | -25°C ~ +50°C(power derated when T>40°C) |
Weight | 15KG |
Weight | 480×370×410mm |
Installing Drawing:
If you are interested in our product, welcome to ask me in the first time.