MC-LC98I Amino Acid Liquid Chromatography
USD $300 - $30,000 /Set
Min.Order:1 Set
Guangzhou Mecan Trading Co., Ltd.
MC-LC98I Amino Acid Liquid Chromatography
model:MC-LC98I
MC-LC98I Amino Acid Liquid Chromatography
No. | Type | Unit | Quantity |
1 | P98I Binary Gradient Pump | set | 1 |
2 | UV98I UV Detector | set | 1 |
3 | Rheodyne 7725i Injector | set | 1 |
4 | C18, 5μm, Amino Acid Column | set | 1 |
5 | Guard Column | set | 1 |
6 | N2000 Work Station | set | 1 |
7 | T98 Column Oven | set | 1 |
8 | Solvent Filter | set | 1 |
9 | 0.45μ Organic Filter membrane | piece | 1 |
10 | 0.45μ Water Filter membrane | piece | 1 |
11 | Organic Sample Filter | piece | 1 |
12 | Water Sample Filter | piece | 1 |
13 | Aspirator Vacuum Pump | set | 1 |
14 | Amino Acid Standard Sample | set | 1 |
15 | Amino Acid Derivatives Solvent | set | 1 |
P98I Binary Gradient Pump
1. SPECIFICATION
a. Operating pressure: 0~42MPa (6000 psi) maximum.
b. Flow rate range: 0.1~15ml/min;
c. Flow rate precision: ±1%;
d. Flow rate accuracy: 25ml/368~387s(±3%);
e. Compositional precision:0.5% absolute
f. Pressure solution: 0.1MPa;
g. Over pressure protection: pump shuts off if pressure exceeds limit specified by user-42.0 MPa(6000 psi) maximum.
2. Environment
a.Temperature requirements: ambient temperature range 10 to 35℃
b. Operates in relative humidity from 5% to 80%;
c. Power requirements: 220Vac±5%,
d.Power frequency: 50±0.5Hz (voltage and frequency specified on the tag attached to the power cord)
3. GENERAL PARAMETERS
a. Power Supply: 400W;
b. Dimensions: 450mm(D)×210mm(W)×390mm(H);
c. Weight: 20kg;
UV98I UV Detector
1. Specification
Wavelength range:190-700nm
Spectral bandwidth:5nm
Wavelength accuracy:±2nm
Wavelength reproducibility:±0.2nm
Absorbance range:
Recorder output:0.002au/mV to 2au/mV in steps of 1, 2, 5
Data system output:2au/V, fixed
Noise:5×10-5au (Peak-Peak)
Test Conditions: Wavelength: 254nm
Mobile phase: methanol
Flow rate: 1ml/min
Time constants: 0.5s
Drift:1×10-3au/hr
Test Conditions: Wavelength: 254nm
Mobile phase: methanol
Flow rate: 1ml/min
Time constants: 0.5s
Flow cell volume:4.5μl
Time constants:0.05s, 0.5s, 5s
Autozero:Yes
2. General Parameters
a. Power Supply: 200W;
b. Dimensions: 450mm(D)×180mm(W)×390mm(H);
c. Weight: 15kg;
Figure 1 18 Amino Acid Stand Sample
1. Asp 2.Glu 3. Ser 4. Gly 5 His 6. Arg 7. Thr 8. Ala 9. Pro 11. Val
12. Met 13. (Cys)2 14. Ile 15. Leu 16. Trp 17. Phe 18. Lys
T98 Column Oven
Temperature range: ambient ~150℃.
Resolution: 1℃ steps
Precision: ±0.5℃
2. General Parameters
Power Supply: 100W;
Dimensions: 450mm(D)×260mm(W)×150mm(H);
Weight: 5kg;