MC-OT-2000 Electric Operating Table

MC-OT-2000 Electric Operating Table

Negotiable /Set

Min.Order:1 Set

Supply Ability:
2000 Set / Sets per Month
Port:
Guangzhou Shenzhen Hongkong Shanghai Yiwu Ningbo
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Type:
Stretcher
Brand Name:
Me Can
Model Number:
MC-OT-2000
Place of Origin:
Guangdong, China

Guangzhou Mecan Trading Co., Ltd.

Business Type: Manufacturer,Trading Company
Guangzhou Guangdong China
Main Products: medical equipment ,ultrasound machine ,laboratory equipment ,hospital bed equipment ,X-ray machine

Product Details

Electric Operating Table

Model:MC-OT-2000

MC-OT-2000 Electric Operating Table

1.Main Usage & Structure:

Electric operating table is suitable for surgical procedures of the head, neck, thorax, abdomen perineum and extremities as well as for gynaecological, obstetrical, urological, otorhino laryngological and orthopaedics operations. It’s raising, lowering, lateral tilt, reversed trendelenburg and trendelenburg , the up-down folding of the back section are all conducted electrically and controlled by buttons.

 

2.Specifications:

Dimension of table top:

Overall Length(2100mm)

Width(480mm)

Dimension of section:

Head Section(280×325mm)

Back Section(500×480mm)

Seat section(530×480mm)

Leg Section(510×236mm)

Foot Section(180×273mm)

Kidney Bridge(100×480mm)

Table top of from floor:

Max Height(1000mm)

Min Height(750mm)

Range of movements:

Reversed Tendelenburg(≥200)

Trendelenburg(≥150)

Lateral tilt(≥150)

Adjustment of sections:

Head Section Raised from the horizontal(≥450)

Head Section lowered from the horizontal(≥900)

Leg Section Lowered from the horizontal(≥900)

Leg Section opened(≥900)

Back Section Raised from the horizontal(≥450)

Back Section lowered from the horizontal(≥150)

Kidney Bridge Elevated(≥100mm)

Safe Working Load(250kg)

Lifting speed(4~16mm/s)

Foot and leg board board into a horizontal or vertical.

IPX4   Ingress Protection:IPX4   

Power: AC220V,50Hz

Internal electric source:(DC)24V

Battery capacity ≥ 2.4AH Device safety sort  I     B

 

3.Structure:

Electric Operating Table is made up of the table top, the main part, the electric controlling part and the accessories, etc. It’s raising, lowering, lateral tilt, trendelenburg and reversed trendelenburg movements ,back section bending are all drived by the motors.

The table top is made up of head section, back section, seat section, leg section and kidney bridge. The head section can be disassembled. The head section can be raised or lowered from the horizontal. The leg section can be lowered from the horizontal and opened. The back section can be raised or lowered from the horizontal. Table top is made of engineering plasties, thus X-ray examination of can be carried out on it.

The main part includes rotary frame, lateral tilt arrangements, trendelenburg and reversed trendelenburg arrangements, ascending and descending arrangements and the base. The lateral tilt

arrangements trendelenburg and reversed trendelenburg arrangements can drive the rotary frams to carry out the lateral tilt, trendelenburg and reversed trendelenburg movements. Ascending and descending arrangements can drive the operating table to ascend or descend.

The electric controlling part is made up of steady power supple, controlling push button container. The power supply of the operating table is connect with alternating current (220V AC), then change it into direct current (24V DC) to drive the motor starter to word.

Electric operating table mattresses are produced by the high-density sponge covered leatherette materials or overall bubble forming, with antistatic properties.

This product is equipped with emergency power supply, and emergency power is lead-acid battery which you can automatically charge, When net power is off , the emergency power source can automatically jump to working condition. Emergency power has charging light. When the green light is bright, it means it is charging. After the power is sufficient, light turns off.

 

4.Instruction of Electric Operating Table:

The ascending and descending movements, lateral tilt movements, reversed trendelenburg and trendelenburg movements of the table top are all electrically operated. It has a moving controlling push button container attached.

The controlling push button are all dot buttons, when the necessary button is rushed, the corresponding motor will work, when the button is not puessde, all movements stop.

1 Connect with power supply.

2 Push the corresponding buttons, the operating table can carry out the action.

3 The motion idler wheel is installed in the pedestal of the operating table, it can be locked to the ground when trampling the side pedal, it can move around when tramping the other side pedal.

4 Operate handle of table, the kidney bridge can ascend or descend, head section raised from the horizontal and elevated.

5 The Company will be able to provide circuit draws in accordance with users’ needs.

 

5.Accessories:

Numberal order

Name of accessories

Number

 

1

Head section

1

 

2

Stand for anaesthetic bottle

1

 

3

Body support

 Large 1.smart 1

 

4

Shoulder support

2

 

5

Arm rest

1

 

6

Knee crutch

2

 

7

Cushion

1

 

8

Foot Section

2

 

9

Body Restraint Strap

1

Optional

10

Handle

1

 

When the product is packaged, all the accessories should be installed in the operating table. Accessories can be selected according to user requirements. When dismounting , just simply loose the fastening handle, then remove the accessories or adjust the positions.

6.Cautions:

1 Before using the operating table, lock all handles tightly,so as to prevent them from loosing or sliding off while used.

2 The operating table can electrically operate 8 movements. These movements must be operated separately. Attention: the product is supplied by single-phase alternating current (220V, 50Hz), tri-socket .Fuse plug rating is 2A .Please carefully inspect socket to insure

reliable earth; shut off power while stop perform. When trouble happen please inform company /agency to assign engineer overhaul, don’t overhaul by yourself.

3 The kidney bridge should be kept on the lowest position, before assemble of the folding back to protect the waist panel.

4 Every time, after the operation, clean the dirt on the table and keep it clean, make the table top be in the horizontal position and descend the kidney bridge.

5 Keep the button container dry and clean to avoid current leakage. Keep it in the proper place after being used.

6 Don’t step on the current mains or controlling mains to avoid breaking the connecting joints or damaging the insulation coat of the wire.

7.Put the operating table in dry place to avoid the electric controlling devices being wet and being damaged.

8 It must be repaired and kept clean regularly, once every year.

9 The replacement parts during Electric operating table’ normal using period, has been confirmed scrapped (unable to use), should be handled according to the classification (recyclable and non-recovery).

10 The service life for Electric operating table is seven years. If it is used in expired period, it maybe led to wearing and corrosion of some mechanical parts, and had a negative influence upon the mechanical intensity. The patients maybe suffered. So the operating table should be used in the regular maintenance and during safety using period.

11  Electric operating table must be used on the antistatic ground.

12  Voltage : 24V emergency power supply, battery capacity ≥ 2.4AH. Emergency power inspection must be operated every six months. The battery should be replaced once a year. If the external protective conductor in the installation or the integrity of the wiring is in doubt, equipment should be supplied to run by the internal power.

13 Please pay attention not to make the metal contact with rechargeable batteries, prevent battery from exposing to high heat, and not to throw the scrapped batteries into the fire.

Warning: electric operating table coupled with high-frequency surgical equipment for use, it is possible for the operator and patients to be burned.

 

7.Cleaning, disinfection and sterilization

7.1.Washing the operating table with water is prohibited.

7.2.Clean operating table with a soft cloth, sponge, wet cloth or detergent. Not use a hard brush, steel wire brush, decontamination powder, paint, ether, bananas water, acid-base solution to any surface.

7.3.Mattress must be disinfection with alcohol, ether, ultraviolet disinfection and so on (abandoning high-temperature disinfection).

 

8.Environmental conditions:

 Transportation and stockpile conditions

 a) Environmental temperature:-40℃~+55

 b) Relative humidity:≤80%

 c) Atmospheric pressure:50kPa~106.0kPa

Moving Environmental conditions:

  a) Environmental temperature:5℃~40

  b) Relative humidity:≤70%

  c) Atmospheric pressure:70.0kPa~106.0kPa

  d) Supply voltage: AC220V±22V,50Hz±1Hz.

 

 This device in package should be stored indoor with a relative humidity less than 80%, no erosive air and good ventilation is required. No side-sloping.

   It can be shipped in regular transportation without crash, oscillation, rain or direct sunlight.

MC-OT-2000 Electric Operating Table

 Please Send inquiry to us for the Electric Operating Table

Contact Supplier

Ms. Jaemin Zhao Manager Chat Now
Telephone
86-20-84835259
Mobile
0086 15802011816
Fax
86-20-84835259
Address
Rm718,Yidong Building, No.301-303,Huanshi Zhong Road, Yuexiu, Guangzhou City, China Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Ward Nursing Equipments
Categories
Hi~