Maternal Fetal Monitor/ Fetal heart beat monitoring
USD $1 - $99,999 /Set
Min.Order:1 Set
Guangzhou Mecan Trading Co., Ltd.
Standard configuration: FHR, TOCO, FM SpO2, NIBP, PR, Twins Function.
Feture:
1. Three in one transducers and avoid the cable intertwinsting, single probe also can offer, nine crystals probe, solid and durable, waterproof and with high sensitivity
2. Built-in fetus waking-up function
3.7 inch TFT color folding display, 90° Turnning angle
4. FHR, TOCO and FM can be displayed by mumber and curve, can changing-over by the user
5.12 hours data storage for review and printed
6. Wide voltage range (100-240V), suitable for different countries
7. Low power of ultrasound, harmless to fetus
8. Alarm function, mark for special and clinical patient, alarm upper and lower limit can be set by the user and the alarm method can optional
9. Adopt DSP technology, recognize and monitor the FHR in real time insure the result accurate and reliable
10. Built-in thermal printer, long using life, Print paper 112mm insure the printed curve clear, printing speed and density are adjustable
11. Information and RJ45 connector, can be connected in the hospital monitor center
12. Can work during charging, high anti-interference ability
GEL: Viscous aqueous non-sensitising, hypo-allergenic and non-irritating to skin. Indefinite shelf life, bacteriostatic (not sterile).
Technical Parameter:
Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitively
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing: special DSP system and modern recognization.
Measurement range: 60 bpm ~210 bpm
Alarm Range:
High limit: 160 bpm,170 bpm,180 bpm,190 bpm
Low limit: 90 bpm,100 bpm,110 bpm,120 bpm
Maximum audio output power : 1.5 Watt
Toco:
Measurement range: 0 units ~100 units
Maternal SpO2 measure:
Measure scope : 70%~99%.
Measure accuracy: ±3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ±2 bpm
NIBP measure:
a) NIBP-SYS 6.7Kpa~32.0Kpa (50mmHg~240mmHg)
b) NIBP-DIA 3.4Kpa~26.6Kpa (25mmHg~200mmHg)
c)NIBP-MEAN 2.0Kpa~24.0kpa (15mmHg~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of the results, take the bigger one.
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Manual
Display:
The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play back the data.
Power: a.c.100v - 240v, 50/60Hz ,d.c.15v or 16.8v Li-ION battery
Power Consumption: < 20W
Dimension: 307mm (length) ×296mm (width) ×101mm (height)
Net weight: Three-parameter type: 2.75kg; nine-parameter type: 3kg. (Both does not contain accessories such as probe)
Environment
Working environment: Temperature: +5ºC ~ +40ºC
Humidity: < 85%
Atmospheric pressure: 86kPa ~ 106kPa
Transport and storage temperature: Temperature: -10ºC ~ +55ºC
Humidity: < 93%
Atmospheric pressure: 86kPa ~ 106kPa
Transducer Acoustic Output:
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure
does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2
and the spatial-peak temporal-average intensity does not exceed 100mW/cm2
Technical parameters | |||
Ultrasound frequency | 1MHz± 5% | ||
Power supply | AC100~240V 50/60Hz | ||
Working temperature (centidegree) | 5~40 | ||
Working humidity | < 85% | ||
Working atmospheric pressure (KPa) | 86~106 | ||
Storage temperature (centidegree) | -10~+55 | ||
Storage relative humidity | < 93% | ||
Storage atmospheric pressure | 86~106 | ||
Machine0.2% Dimension (mm) | |||
Net weight | |||
FM | Button hand count automatic cumulative number of movement | ||
ECG | Range | 30~300bpm | |
Accuracy | ± 1bpm | ||
Choice | I, II. III, AVR, AVL, AVF, V | ||
Scan speed | 12.5/25/50mm/s | ||
Gain choice | *0.25, *0.5, *1, *2 | ||
Application | Diagnosis, monitor, surgery | ||
RESP | Range | 1~99rpm | |
Resolution | 1rpm | ||
Accuracy | ± 2rpm | ||
TEMP | Range | 26~45 centidegree | |
Resolution | 0.1centidegree | ||
Accuracy | ± 0.2% | ||
FHR | Ultrasound intensity | < 5mW/cm 2 | |
Measure range (bpm) | 50~210 | ||
Alarm range (bpm) | H: 160/170/180/190 | ||
L: 90/100/110/120 | |||
Maximum audio output power | 1.5W | ||
TOCO | Measure range | 0~100 unit | |
Resolution | 1 | ||
Non-linear error | ≤ ± 5% | ||
Maternal HR | Measure scope (bpm) | 30~240 | |
Measure accuracy (bpm) | ± 2 | ||
Maternal SPO2 | Measure scope | 70%~99% | |
Resolution | 1% | ||
Measure accuracy | ± 2bpm | ||
NIBP | Systolic pressure | 50~240 mmHg | |
Diastolic pressure | 15~180 mmHg | ||
Mean pressure | 25~200 mmHg | ||
NIBP accuracy | ± 8mmHg | ||
PR | PR range | 40~240bpm | |
Mode | Automanual | ||
Resolution | 1 mmHg | ||
PR accuracy | ± 2bpm |