Product Details

 

Multi-Parameters fetal monitor MC-600P(7 inch) CE marked

 

Bedside care, normal hospital monitor
Maternal Fetal Monitor/ Fetal heart beat monitoringMaternal Fetal Monitor/ Fetal heart beat monitoring

 

 

Standard configuration: FHR, TOCO, FM SpO2, NIBP, PR, Twins Function.

Feture:

1. Three in one transducers and avoid the cable intertwinsting, single probe also can offer, nine crystals probe, solid and durable, waterproof and with high sensitivity
2. Built-in fetus waking-up function
3.7 inch TFT color folding display, 90° Turnning angle
4. FHR, TOCO and FM can be displayed by mumber and curve, can changing-over by the user
5.12 hours data storage for review and printed
6. Wide voltage range (100-240V), suitable for different countries
7. Low power of ultrasound, harmless to fetus
8. Alarm function, mark for special and clinical patient, alarm upper and lower limit can be set by the user and the alarm method can optional
9. Adopt DSP technology, recognize and monitor the FHR in real time insure the result accurate and reliable
10. Built-in thermal printer, long using life, Print paper 112mm insure the printed curve clear, printing speed and density are adjustable
11. Information and RJ45 connector, can be connected in the hospital monitor center
12. Can work during charging, high anti-interference ability

GEL: Viscous aqueous non-sensitising, hypo-allergenic and non-irritating to skin. Indefinite shelf life, bacteriostatic (not sterile).

Technical Parameter:

Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitively  
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing:  special DSP system and modern recognization.
Measurement range:  60 bpm ~210 bpm
Alarm Range:
High limit: 160 bpm,170 bpm,180 bpm,190 bpm
Low limit: 90 bpm,100 bpm,110 bpm,120 bpm
Maximum audio output power : 1.5 Watt
Toco:
Measurement range: 0 units ~100 units
Maternal SpO2 measure:
Measure scope : 70%~99%.
Measure accuracy: ±3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ±2 bpm
NIBP measure:
a)   NIBP-SYS  6.7Kpa~32.0Kpa (50mmHg~240mmHg)
b)  NIBP-DIA  3.4Kpa~26.6Kpa (25mmHg~200mmHg)
c)NIBP-MEAN 2.0Kpa~24.0kpa (15mmHg~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of the results, take the bigger one.
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm  
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Manual 
Display:
The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play back the data.
Power: a.c.100v - 240v, 50/60Hz ,d.c.15v or 16.8v Li-ION battery
Power Consumption: < 20W
Dimension: 307mm (length) ×296mm (width) ×101mm (height) 
Net weight: Three-parameter type: 2.75kg; nine-parameter type: 3kg. (Both does not contain accessories such as probe)
Environment 
Working environment: Temperature: +5ºC ~ +40ºC
Humidity: < 85%
Atmospheric pressure: 86kPa ~ 106kPa
Transport and storage temperature: Temperature: -10ºC ~ +55ºC
Humidity: < 93%
Atmospheric pressure: 86kPa ~ 106kPa
Transducer Acoustic Output: 
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure
does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 
and the spatial-peak temporal-average intensity does not exceed 100mW/cm2



Technical parameters
 
Ultrasound frequency1MHz± 5%
Power supplyAC100~240V 50/60Hz
Working temperature (centidegree)5~40
Working humidity< 85%
Working atmospheric pressure (KPa)86~106
Storage temperature (centidegree)-10~+55
Storage relative humidity< 93%
Storage atmospheric pressure86~106
Machine0.2% Dimension (mm) 
Net weight                 
FMButton hand count automatic cumulative number of movement
ECGRange30~300bpm
Accuracy± 1bpm
ChoiceI, II. III, AVR, AVL, AVF, V
Scan speed12.5/25/50mm/s
Gain choice*0.25, *0.5, *1, *2
ApplicationDiagnosis, monitor, surgery
RESPRange1~99rpm
Resolution1rpm
Accuracy± 2rpm
TEMP                 Range26~45 centidegree
Resolution0.1centidegree
Accuracy± 0.2%
FHRUltrasound intensity< 5mW/cm 2
Measure range (bpm)50~210
Alarm range (bpm)H: 160/170/180/190
L: 90/100/110/120
Maximum audio output power1.5W
TOCOMeasure range0~100 unit
Resolution1
Non-linear error≤ ± 5%
Maternal HRMeasure scope (bpm)30~240
Measure accuracy (bpm)± 2
Maternal SPO2Measure scope70%~99%
Resolution1%
Measure accuracy± 2bpm
NIBPSystolic pressure50~240 mmHg
Diastolic pressure15~180 mmHg
Mean pressure25~200 mmHg
NIBP accuracy± 8mmHg
PRPR range40~240bpm
ModeAutomanual
Resolution1 mmHg
PR accuracy± 2bpm

 

contact us -Paula

Maternal Fetal Monitor/ Fetal heart beat monitoring

Maternal Fetal Monitor/ Fetal heart beat monitoring 

Contact Supplier

Ms. Jaemin Zhao Manager Chat Now
Telephone
86-20-84835259
Mobile
0086 15802011816
Fax
86-20-84835259
Address
Rm718,Yidong Building, No.301-303,Huanshi Zhong Road, Yuexiu, Guangzhou City, China Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Dental Equipments
Categories
Hi~