fully automated blood grouping system AISEN 170
USD $1 - $1 /Set
Min.Order:1 Set
Yantai Addcare Bio-Tech Limited Company
Addcare AISEN 170 | |||
General | Fully automated Blood grouping system | ||
Test Menu | Blood grouping/ reverse grouping/ phenotyping/ crossmatching/ antibody screening/ antibody identification/ direct AHG test(DAT)/ single antigens/Rh(D) Rh(CcEe)/Newborn-ABO-Rh/ Rh/k/ ABO DD/Kell/ AHG Polyspecific/ ADK | ||
Typical throughput | up to 96 cards/ hour | ||
Transfer arm/gripper | 1 (transfer card) | ||
Pipetting channels | 2 (800ul disposable plastic tips, non conductive, low cost, Liquid level, clot, empty tube detection) | ||
Piercing module | 12 cards position | ||
Tips rack capacity | 384 tips (4 positions, each can hold 96tips) | ||
Pipetting range | Range: 10 to 800ul/ Increment: 1ul | ||
Sample tube capacity | 24 X 6 = 144 samples (standard tube diameter 13mm, other diameters on request) | ||
Sample types | centrifuged whole blood/ packed red blood cells/ 3-5% and 0.8% red cell suspensions/serum or plasma | ||
Reagent module | 2 X6=12 blending diluent position+96 deepwell dilution microplate+2 dilution position+2control | ||
Incubation module | 12X2=24 cards position (RT- 50℃ adjustable at an increment of 0.1℃ ) | ||
Centrifuge | 12X2=24 cards position (maximum speed 3000r/min, Centrifugal time, speed adjustable programming) | ||
Gel card box | 24X4=96 card capacity | ||
Barcode scanner | 2 (1 for sample and reagent, 1 for gel card) | ||
Reader | High resolution image acquisition interpretation system, automatic interpretation of acquisition and recognition results.The background of back light system, original image is clear and permanent, easy to query and tracking. | ||
Software | Completely intellectual property rights, humanization design, Wizard-style user interface, easy to use | ||
Bi-directional LIS/HIS connection, evaluate and send results | |||
Software interface synchronous operation, synchronous refresh, visual display running state | |||
Operating process real-time monitoring, early warning function with abnormal situation | |||
Perfect function of experiment process tracking function of full trace ability tracking analysis and quality control. | |||
Powerful memory storage support testing result recheck include original picture, sample nubber, reagent message,reading result,operator,testing time,test protocol, test method and etc. | |||
Certification | ISO 13485:2003 ISO9001:2008 | ||
YANTAI ADDCARE BIO-TECH LIMITED COMPANY | |||
Address: 7 Hanjiang Road, Development Zone, Yantai City 264006, Shandong Province, China | |||
Marketing Department Tel : +86 535-6398536 Fax:+86 535 6398506 | |||
Website : Addcare 20160120. |