2 channels chemiluminescence processor
USD $1 - $1 /Piece
Min.Order:1 Piece
Yantai Addcare Bio-Tech Limited Company
Automatic Chemiluminescence Analyzer/Addcare CLIA Immunoassay Workstations | |||
Addcare CLIA Immunoassay Workstations Addcare‘s range of immunoassay workstations combine all functions required to process microplate based immunoassays on an efficient, convenient and fast platform. Sample- and reagent transfer are performed by the high precision pipetting system. An array of shaker-incubators carry the microplates, assure accurate reaction temperature and efficient mixing. A high performance 96-well microplate washer module provides fast and efficient washing. The measurement module selected to match your specific assay technology ELISA, CLIA or FIA, provides reliable raw data to be evaluated and the plate transfer arm moves the plate between the modules used for each individual processing step. The system is complemented by ADCstation, a powerful PC-software providing an intuitive user interface to control all system functions, define and execute the desired processes, perform evaluation and provide access to results and process data. | |||
Model | ADC CLIA 200 | ADC CLIA 300 | |
Design | benchtop | cabinet | |
Pipetting channels | 2 | 2 | |
Worktable size | 1085 x 580 | 1315 x 730 | |
WxD mm | |||
Tube carriers | 6 | 8 | |
(144 tubes) | (192 tubes) | ||
Each sample tube carrier can hold up to 24 tubes with a diameter of 12mm | |||
Plate carriers | 9 positions in total | 9 positions in total | |
(6 shaker incubators | (6 shaker incubators | ||
and 3 ambient) | and 3 ambient) | ||
Microplate washer | 16-channels | ||
Tip racks | One tip rack holding up to 4 sets of 96 tips (up to 384 tips in total) | ||
Tip eject station | With a waste container installed below the worktable | ||
Model | ADC CLIA 400 | ADC CLIA 600 | ADC CLIA 1100 |
Design | cabinet | cabinet | dual cabinet |
Pipetting channels | 4 | 8 | 8 in front cabinet + 4 in rear cabinet |
Worktable size | 1315 x 730 | 1675 x 820 | 3170 x 820 |
WxD mm | |||
Tube carriers | 8 | 10 | 10 |
(192 tubes) | (240 tubes) | (240 tubes) | |
Each sample tube carrier can hold up to 24 tubes with a diameter of 12mm | |||
Plate carriers | 9 | 16 | 16 + 16 |
shaker incubators | shaker incubators | shaker incubators | |
Microplate washer | 96-well microplate washer | 3 x 96-well washer | |
Tip racks | One tip rack holding up to 4 sets of 96 tips (up to 384 tips in total) | ||
Tip eject station | With a waste container installed below the worktable | ||
SKYPE:carolyn667799