immunofluorescence assays
Negotiable /Piece
Min.Order:1 Piece
Yantai Addcare Bio-Tech Limited Company
immunofluorescence assays |
Automated Chemiluminescence test equipment
Software
Completely independent intellectual property rights
Professional fully automated experiment platform designed for you specially
Unique sporadic detection mode, realize sample automated selected
Intelligent program, different items and different batches can be run together.
Suit for both small batch sporadic detection and realize experiment maximization
Meet different laboratory’s requirement
Interface of software and hardware synchronous operation, synchronous refreshing, visual display real time operating status.
Intelligent automated running support system
Adjustable channel running mode, if any channels breakdown, the other channels left can run continuously.
Opening operating worktable
Components can be changed independently, easy to operate, ensure the precision of the testing result, meet the laboratory diverse testing requirement.
Accurate and precise integrated module
Pipetting module
Pipetting principle: Air displacement pipetting
2 Channel adopting disposable TIP, completely avoid sample cross contamination and dilution of liquid
Unique TIP fixing real time monitoring function
Real time monitoring during tip fixing, running, unfixing, can ensure there’s no missing test.
Three liquid level monitoring
Liquid level monitoring, clot monitoring, empty tube monitoring, can ensure the precision of pipetting.
Washing module
16needle washer, high speed and less liquid remained
Washing 96 well microplates at same time, improve the efficiency of washing plate.
Diverse washing parameter can be set to ensure the quality of washing.
Incubating module
4 plate position can be shaken and incubated under controlled temperature at same time to ensure large batches testing and improve the efficiency of testing.
Intelligent transfer arm can auto recognize the size of the microplate, can rapidly, precisely and stably collect microplate, would not drop the plate even power failure.
Could auto recognize the size of the microplate; could rapidly, precisely and stably collect microplate; would not drop the plate even power failure.
Interpretation module: sensitive, rapid, wide application
Repeatability: CV<3%
Linear range: 100/S~2.0x107/S
Wide application: clinical diagnostic field, biological science filed, DNA assay, ATP test and agriculture field.
STANDARD CONFIGURATION
Specifications | ADC CLIA200 | |
Pipetting Spec | Continuous load sample, parallel serial pipetting | |
Sample and reagent pipetting Probe | 2pc | |
Tip type | Disposable plastic tips, non conductive, low cost Liquid level, clot, empty tube detection function | |
Sample-tip range | Tip type 300µL,800µL optional | |
Tips rack capacity | 384tips(4positions, each can hold 96tips) | |
Replicates | Up to 120 samples, standards and controls | |
Accuracy | ≤2.0%( 100µl) | |
Precision | ≤0.75%( 100µl) | |
Reagent fluid capacity | Standard:24reagent tanks position | |
Intelligent transfer arm | 1pc, grab the plate tightly, avoid dropping | |
Incubator Spec |
| |
Incubation plates | 4pc, 1pc RT position, each plate up to 12 assays | |
Temperature range | Ambient +5 oC--60 oC uniformity ±0.5oC | |
Shaking, temperature control | 3 Independent shaking , parameters can be set | |
Washer Spec |
| |
Manifold configuration | 8-pin washer | |
Dispense-volume range | 50-1000µl, residual volume<2µL | |
Cross washing function | Yes, liquid inject height, soak time etc multi-parameter programmable | |
Wash buffer capacity | 3x 2L Low-buffer alarm function | |
Reader Spec | 1 no. linear range:100/s~2.0x107/s, CV<3% | |
HIS/LIS, CE certificate, ISO9001,ISO13485, Completely intellectual property rights | ||