hybrid solar charge controllers MPPT 100A
USD $50 - $1,000 /Unit
Min.Order:100 Units
Foshan Baykee New Energy Technology Incorporated Company
MPPT solar charge controller 12V/24V48V/192V/360V 60A/100A Quality Choice Supplier's Choice
high quality with mppt solar controller which for solar system
High Quality solar controller system 96v 60a solar controller
High Quality solar controller system 100a mppt solar charge controller
High Quality solar controller system automatic light control
Can set parameters via PC upper software
Models: 12V/24V/48V-series | 15A | 20A | 25A | 30A | 40A | |
Charge mode | MPPT(maximum power point tracking) | |||||
Charge method | Three stages: constant current(MPPT),constant voltage,floating charge | |||||
System type | DC12V/24V/48V | Automatic recognition | ||||
System voltage | 12V system | DC9V~DC15V | ||||
24V system | DC18V~DC30V | |||||
48V system | DC36V~DC60V | |||||
Soft start time | 12V/24V/48V system | ≤3S | ||||
Dynamic response recovery time | 12V/24V/48V system | 500us | ||||
MPPT efficiency | 12V/24V/48V system | ≥96.5%, ≤99% | ||||
INPUT CHARACTERISTICS | ||||||
MPPT working voltage range | 12V system | DC14V~DC100V | ||||
24V system | DC30~DC100V | |||||
48V system | DC60~DC100V | |||||
Low input voltage protection point | 12V system | DC14V | ||||
24V system | DC30V | |||||
48V system | DC60V | |||||
Low input voltage Recovery point | 12V system | DC18V | ||||
24V system | DC34V | |||||
48V system | DC65V | |||||
High input voltage protection point | 12V/24V/48V system | DC110 | ||||
High input voltage recovery point | 12V/24V/48V system | DC100V | ||||
Maximum PV power | 12V system (W) | 213 | 284 | 355 | 426 | 568 |
24V system (W) | 426 | 568 | 710 | 852 | 1136 | |
48V system (W) | 852 | 1136 | 1420 | 1704 | 2272 | |
CHARGE CHRECTRESTICS | ||||||
Selectable Battery Types (Default Gel battery) | 12V/24V/48V system | Sealed lead acid, Vented, Gel, NiCd battery (Other types of the batteries also can be defined) | ||||
Constant Voltage | 12V/24V/48V system | Please check the charge voltage according to the battery type form. | ||||
Floating Charge Voltage | 12V/24V/48V system | |||||
Rated Input Current | 12V/24V/48V system | 15A | 20A | 25A | 30A | 40A |
Current-limit Protection | 12V/24V/48V system | 20A | 25A | 30A | 35A | 45A |
Temperature Factor | 12V/24V/48V system | ±0.02%/℃ | ||||
Temperature Compensation | 12V/24V/48V system | 14.2V-(The highest temperature-25℃)*0.3 | ||||
Output Ripples(peak) | 12V/24V/48V system | 200mV | ||||
Output Voltage Stability Precision | 12V/24V/48V system | ≤±1.5% | ||||
Output Discharge Characteristics | ||||||
Output voltage | Base on battery voltage | |||||
Low voltage output Protection point | Default 10.5V; Recovery 11V; It can be adjustable | |||||
Rated output Current | 30A | |||||
The output control | On mode, Off mode, PV voltage control mode | |||||
Output control set mode | Controller button or PC software | |||||
Display | ||||||
LED digital tube display | Battery voltage, Charge current | |||||
LED light display | Charging indicator light, LOAD indicator light | |||||
PC (communication port) | RS232 | |||||
Protection | ||||||
Low input voltage protection | Check the input characteristics | |||||
High input voltage protection | Check the input characteristics | |||||
Charge overpower protection | yes | |||||
Discharge low voltage protection | yes | |||||
Discharge high current protection | yes | |||||
Temperature protection | yes | |||||
Other Parameters | ||||||
Noise | ≤40dB | |||||
Thermal heat-dissipating method | Itself cooling | Fan cooling | ||||
Components | Imported material With EU standards | |||||
Certification | CEFCCRoHS | |||||
Physical | ||||||
Measurement D x W x H(mm) | 205*168*60 | |||||
Package size D x W x H(mm) | 265*196*110 | |||||
N.G(KG) | 1.8kg | |||||
G.N(KG) | 2kg | |||||
Mechanical Protection | IP25 | |||||
Environment | ||||||
Humidity | 0~90%RH ( no condense) | |||||
Altitude | 0~3000m | |||||
Operating Temperature | -20℃ ~ +50℃ | |||||
Storage Temperature | -40℃ ~ +75℃ | |||||
Atmospheric Pressure | 70~106kPa | |||||
* The specification is only for reference. Subject to change without further notice |