Baykee Home Emergency Power 48 VDC UPS With Pure Sine Wave
USD $1 - $999 /Piece
Min.Order:50 Pieces
Foshan Baykee New Energy Technology Incorporated Company
Baykee Home Emergency Power 48 Vdc UPS With Pure Sine Wave
HD series ups is a smart multifunctional line interactive ups, consisting of inverters, automatic voltage regulator, conversion circuit, main control circuit and display alarm circuits, etc. designed to protect your computer and other important electronic equipment from power failure, brownouts, sags and surges. The ups can filter out the small voltage fluctuations, when meeting big voltage disturbance, ups can disconnect AC input by ups internal circuit, so that avoid influencing your equipment. UPS can offer uninterruptible power supply by lead acid battery or lithium battery until the utility power recover normally. when the utility power is normal, UPS has voltage regulation function by internal automatic voltage regulator. meantime charge the battery. When the utility power is unnormal, ups can change the battery energy into pure sine wave AC power, make the load work.
Apply to Computer center, Network management center, Communication system, Automatic control system, Precision instrument and equipment, household appliances etc. widely apply to home inverter power supply and solar energy off grid inverter power supply (configurate solar panels and solar controller) etc.
Main features:
1. Online interactive mode design: high-efficiency, high-power charging.
2. Adaptive output frequency adjustment: By automatically tracking the input frequency, adjust the battery inverter's output frequency, when just Battery inverter without utility power, can switch the output frequency via ups front panel.
3. Intelligent interactive regulator: Relay fast interactive switch, with wide input voltage range, improve the output voltage regulation accuracy.
4. Intelligent digital control technology: Adopts 32-bit high-speed microcontroller circuit control, parameter setting, operation management, advanced self-test and self-detection feature, can self-test and fault analysis all the independent circuit on the circuit board to perform a self-test and fault analysis. Adopt SPWM conversion technology, pure sine wave output, to meet your needs.
5. Efficient inverter technology: Adopt ultra-low internal resistance power MOSFET as a power conversion switch, make the work efficiency of the inverter higher, make the performance more stable and reliable.
6. Perfect protection features: input voltage, frequency overrun protection, surge voltage protection, over-current protection, output short circuit protection, over temperature protection, battery overcharge and over discharge protection.
7. Intuitive LED status indicator: the workflow type status indication at a glance.
8. Humane screen dynamic LCD display: the operational status and data visual display, multi-screen data query.
9. Output no-load protection function: when the battery inverter work, if the output load is very small, five minutes will automatically shut down-load protection.
10. High-performance dynamic characteristics: a variety of feedback control using the the instantaneous control mode and rms, both to achieve a high dynamic adjustment, but also reduce the distortion of the output voltage.
11. Intelligent battery management: three-stage intelligent battery charging, automatic battery powered environment are charging and float conversion, temperature compensated charging, discharge management to extend battery life and reduce the burden on the administrator.
12. Intelligent detection function: the system microprocessor from time to time for all the power state, breaker status, fuse status and all the circuit work state line detection, if any fault protection and alarm to notify the administrator immediately.
Rated Capacity(VA) | 500VA | 750VA | 1000VA | 1200VA | 1500VA | 2000VA | 3000VA | 4000VA | 5000VA | |
Output voltage(W) | Rated Capacity*0.8 | |||||||||
Work mode | Low frequency online interactive | |||||||||
Phase | Single phase( L+N+G ) | |||||||||
Rated Input voltage | 100/110/115/127V;220/230/240V ( According to the user's power standard ) | |||||||||
Input voltage range | ±25% | |||||||||
Input nominal frequency | 50/60Hz ( adaptive adjustment ) | |||||||||
Input voltage range | ±5% | |||||||||
Voltage stabilizingfunction | Adopt Relay smart multi-gear adjusting voltage | |||||||||
Voltage stabilizing output precision | ±5% | |||||||||
Rated Battery Voltage | 12V/24V/48V/96V/110V/220V (12V only used for 500VA~750VA,24V only used for 1000VA~1500VA, 48V only used for 2000VA~5000VA ) | |||||||||
Charge mode | three-stage intelligent battery charging | |||||||||
Float charging voltage | 13.5V/27V/54V/108V/121.5V/243V | |||||||||
Equalized charging voltage (optional) | 14.1V/28.2V/56.4V/112.8V/126.9V/253.8V | |||||||||
Temp. Compensation voltage | 3mV/°C(cell battery) | |||||||||
Charge power | Rated capacity*20% | |||||||||
Output phase | Single phase(L+N+G) | |||||||||
Nominal voltage | Equal to input rated voltage | |||||||||
Inverter output voltage | 100/110/115/127V;220/230/240V ( According to the user's power standard ) | |||||||||
Inverter voltage stability | ±1%(steady load ), ±3% (fluctuation of load ) | |||||||||
Inverter frequency stability | 50Hz, 60Hz | |||||||||
Crest factor | >3:1 | |||||||||
Inverter output waveform distortion degree | Pure sine wave, Linear load | |||||||||
Transfer time | <4ms | |||||||||
Overload protection | Overload level | utility power mode | Battery mode | |||||||
105%~125% | >10mins | >1mins | ||||||||
125%~150% | >1mins | Immediate protection | ||||||||
>150% | Immediate protection |
| ||||||||
Input protection | Voltage, frequency ultralimit protection | |||||||||
Output protection | Overcurrent, short circuit protection | |||||||||
Battery protection | Overcharge, overdischarge protection | |||||||||
Temperature protection | Over- temperature protection | |||||||||
Hardware fault protection | Fuse over current protection, surge voltage protection | |||||||||
Alarm function | Audio alarm | |||||||||
Work Environment | Temperature: 0~40°C, Relative humidity: 30%~90% , Altitude | |||||||||
Cooling method | Forced ventilation | |||||||||
Communication interface | RS232(optional usb, snmp card ) | |||||||||
Protection level | IP30 | |||||||||
Safety performance | I/O on ground resistance (3000VAC), stray current less than 3.5mA, insulation resistance exceeding 2MΩ(500VDC) | |||||||||
Tower type dimension (W*H*D) mm | 145×225×360 | 195×345×460 | 195×445×500 | |||||||
Rack-mounted type dimension (W*H*D) mm | 482×88×300 | 482×133×400 | 482×222×450 |