solar batteries 1kw 2kw 3kw 5kW off gird solar inverter
USD $200 - $800 /Set
Min.Order:1 Set
Foshan Baykee New Energy Technology Incorporated Company
Quiet, high efficient
Can connect battery
Humanization panels display
High overload capacity
Backup power supply with quick switch
Three-stage charging
30A/60A automatic three-stage battery charger
Series (SNS) | Model | |||||||
1012 | 1024 | 2012 | 2024 | 3024 | 3048 | 5048 | 6048 | |
1000W | 1000W | 2000W | 2000W | 3000W | 3000W | 5000W | 6000W | |
DC12V | DC24V | DC12V | DC24V | DC24V | DC48V | DC48V | DC48V | |
Utility Pattern Specification: | ||||||||
Input Wave Form | Sine wave (Utility or generator) | |||||||
Nominal Voltage | 230VAC | |||||||
Low Voltage Trip | 184VAC±4% | |||||||
Low Voltage Reengage | 194VAC ±4% | |||||||
High Voltage Trip | 253VAC±4% | |||||||
High Voltage Reengage | 243VAC±4% | |||||||
Max. AC Input Voltage | 270Vrms | |||||||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detect) | |||||||
Low Frequency Reengage Frequency | 58+0.3Hz(60Hz); 48+0.3Hz(50Hz); | |||||||
Low Frequency Trip Frequency | 57+0.3Hz(60Hz); 47+0.3Hz(50Hz); | |||||||
High Frequency Reengage Frequency | 64+0.3Hz(60Hz); 54+0.3Hz(50Hz); | |||||||
High Frequency Trip Frequency | 65+0.3Hz(60Hz); 55+0.3Hz(50Hz); | |||||||
Output Wave Form | Bypass mode, same as input | |||||||
Overload Protection | Circuit Breaker | |||||||
Short Circuit | Circuit Breaker | |||||||
Efficiency | >95% | |||||||
Transfer Switch Current | 30A | |||||||
Transfer Time (Ac to Dc) | 10ms | |||||||
Transfer Time (Dc to Ac) | 10ms | |||||||
Bypass without Battery Connected | yes | |||||||
Max. Bypass Current | 30A |
Inverter Pattern Specification: | |||||||||||||
Series (SNS) | Model | ||||||||||||
1012 | 1024 | 2012 | 2024 | 3024 | 3048 | 5048 | 6048 | ||||||
Output wave form | Sine wave | ||||||||||||
Nominal Output Capacity (VA) | 1000 | 2000 | 3000 | 5000 | 6000 | ||||||||
Nominal Output Power (W) | 1000 | 2000 | 3000 | 5000 | 6000 | ||||||||
Power Factor | 0.9~1.0 | ||||||||||||
Nominal Output Voltage (V) | 230Vac | ||||||||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | ||||||||||||
Automatic tracking main frequency(Hz) | Yes( start from the first connection ) 50Hz @48-54Hz 60Hz @58-64Hz | ||||||||||||
Output Voltage Regulation | ±10% rms | ||||||||||||
Efficiency | >80% | ||||||||||||
Overload Protection (SMPS load) | (110%< Load <125%) ±10%: No Output after 15mins, (125%< Load <150%) ±10%: No Output after 10S, Load>150% ±10%: No Output after 20S | ||||||||||||
Surge ratings (10s) | 3000VA | 6000VA | 9000VA | 15000VA | 18000VA | ||||||||
Starting Motor | 1HP | 2HP | 3HP | 5HP | 6HP | ||||||||
Short Circuit protection | Current limit (fault after 10s) |
| |||||||||||
Circuit breaker Size | 30A | 30A | 30A | 50A | 50A | ||||||||
Nominal DC Input Voltage | 12V/24V/48V | ||||||||||||
Minimum DC Voltage | 10V/20V/40V | ||||||||||||
Low Voltage Alarm | 10.5Vdc±0.3Vdc(12V)/21.0Vdc±0.6Vdc(24V)/42.0Vdc±1.2Vdc(48V) | ||||||||||||
Low Voltage Trip | 10.0Vdc±0.3Vdc(12V)/20.0vdc±0.6Vdc(24V)/40.0Vdc±1.2Vdc(48V) | ||||||||||||
High Voltage Alarm | 16.0Vdc±0.3Vdc(12V)/32.0Vdc±0.6Vdc(24V)/64.0Vdc±1.2Vdc(48V) | ||||||||||||
High Voltage reengage | 15.5Vdc±0.3Vdc(12V)/31.0Vdc±0.6Vdc(12V)/62.0Vdc±1.2Vdc(48V) | ||||||||||||
Power Saver | Load<=25W | ||||||||||||
|