high frequency online ups circuit diagram 1KVA~3KVA
USD $100 - $1,000 /Piece
Min.Order:1 Piece
Foshan Baykee New Energy Technology Incorporated Company
Computer UPS power supply On-line UPS
Introductions
HS series intelligent pure sine wave online UPS, the capacity can be from 1KVA~10KVA (single phase in and single phase out), HS series congregates the essence of Baykee advanced technology and the world’s most advanced 16-bit high speed CPU control technology and 40KHZ high frequency technology. The UPS has small volume, light weight, high efficiency, zero transfer time and pure sine wave output etc. features. This series UPS adopts the most advanced interface information operation technology, the user can see the UPS operation status directly from the LCD. With digital self-detecting and protection function, the long distance monitoring can reach the international advanced level. It is the power guard for your commercial server, PC server and peripheral, communication and internet equipment, PC and the other nicety electronic equipment.
Applications
It can be widely applied to data processing center, host system, integrated computer network, ISP service, telecom, computer room (Data Center) etc.
Main Features
1. Digital Design
Adopted DSP control technology and digital design topology, C UPS can be operated and maintained more conveniently.
2. Reversed Polarity N and L wire Detection Function.
Reversed polarity of wiring or input protective grounding-wire is abnormal, at this point the indicators will alarm blink cyclically.
3. A Real Green-environmental Protection Power.
The commercial power input factor correction technique is used under the Normal mode, UPS achieves real energy-saving by inputting harmonic less than 10% and frequency power factor above 99%.
4. Direct Current Cold Start Function
When battery input voltage in the range of normal voltage. By pressing the ON button, UPS can start up normally.
5. Alarm High-low Battery Input Voltage Protection Function
UPS alarms in case of the battery input voltage too high or too low. As the battery continuously go up or down out of the normal range, UPS will alarm and stop input or transfer to bypass mode to ensure the battery life and protect user equipment.
6. Communication and Monitoring Function
Equipped with standard RS232 interface and intelligent slot. The UPS Operating and electrical parameters can be monitored through standard RS232. Through intelligent slot status inter face he intelligent control can be flexibly configured according to different applications to users, for instance stem node, network, monitoring, text message.
7. Output High-Low Voltage Protection
When UPS output is greater than the output over-voltage protection point or less than the output low-voltage protection point, it will shut off inverter output to bypass and automatically alarm. After all the fault removed, users can restart the machine normally.
8. Output Short Circuit Protection
When the Inverter output overloaded and short circuit, UPS will stop output and alarm and blink continuously. After the troubleshooting, it can restart normally.
9. Overloaded Protection Function
When Overload out of ranged load in certain time, UPS will turn off the inverter and switch to Bypass output by alarming. After the load back to normal, UPS automatically transfer back to inverter output.
10. Over-temperature Protection
When the temperature is over high or the fan work abnormally, it will lead the main radiator temperature out of over temperature protection. At that point, UPS will alarm and switch to Bypass output. Until the temperature recover normally, UPS will automatically switch to inverter output.
11. Intelligent Fan Speed Control Function
According to load capability and environmental temperature, the fan speed adjustment can reduce the noise and prolong the service life.
HS-6KH HS-10KH
HS-6KS HS-10KS
HS-1KH/HS-1KS | HS-2KH/HS-2KS | HS-3KH/HS-3KS | HS-6KH/HS-6KS | HS-10KH/HS-10KS | ||
Phase | Single Phase & earth ground | |||||
Rated Power | 1kva/0.8kw | 2kva/1.6kw | 3kva/2.4kw | 6kva/4.8kw | 10kw/8kw | |
Input | ||||||
Voltage Range | Low Voltage Conversion | 160VAC+-5% or 80VAC+-5% @100% Load 110VAC+-5% or 50VAC+-5% @ 50% | 176VAC+-3% @ 100% Load 110VAC+-3% @ 50% Load | |||
Low Voltage Recovery | 175VAC+-5% or 85VAC+-5% @ 100% Load | 186VAC+-3% @ 100% Load 120VAC+-3% @ 50% Load | ||||
High Voltage Conversion | 300VAC+-5% or 150VAC+-5% | 300VAC+-3% | ||||
High Voltage Recovery | 290VAC+-5% or 145VAC+-5% | 290VAC+-3% | ||||
Frequency Range | 40Hz~70Hz | 46Hz~54Hz or 56Hz~64Hz | ||||
Power Factor | >=0.99 @ Nominal Voltage(100% Load) | |||||
Output | ||||||
Output Voltage | 208//220/230/240VAC or 110/115/120/127VAC | 208//220/230/240VAC or 110/115/120/127VAC | ||||
Voltage Range( battery mode) | +-1% | |||||
Frequency Range (Synchronous correction range ) | 47~53Hz or 57Hz~63Hz | 46~54Hz or 56Hz~64Hz | ||||
Frequency Range(Battery Mode) | 50Hz+-0.25Hz or 60Hz+-0.3Hz | 50Hz+-0.1Hz or 60Hz+-0.1Hz | ||||
Surge Ratio | 3:1 | |||||
Harmonic Distortion | <=2% THD (Linear Load), <=4% THD (nonlinear Load) | <=3% THD (Linear Load), <=6% THD (nonlinear Load) | ||||
Transfer Time | AC to DC | Zero | ||||
Inverter to Bypass | 4ms(Typical) | Zero | ||||
Waveform (Battery Mode) | True pure sine wave | |||||
Efficiency | ||||||
AC Mains Mode | 87% | 90% | 89% | |||
Battery Mode | 83% | 87% | 88% | |||
Battery | ||||||
Standard Machine | Battery | 12V7Ah | 12V7Ah | 12V9Ah | 12V7Ah | 12V9Ah |
Number | 3 | 6 | 6 | 16 | 16 | |
Charge Time | 4hours charging to 90% | 7hours charging to 90% | 9hours charging to 90% | |||
Max. Charge Current | 1.0A | |||||
Charge Voltage | 41.0VDC+-1% | 82.1VDC+-1% | 219.2VDC+-1% | |||
Long backup time machine | Battery | External Battery | ||||
Number | ||||||
Charge Time | 1.0A/2.0A/4.0A/6.0A | 4.0A | ||||
Max. Charge Current | 41.0VDC+-1% | 82.1VDC+-1% | 219.2VDC+-1% | |||
Display | ||||||
LCD or LED | Load, Battery capacity, AC mains mode, Battery mode, Bypass mode, Fault indicator | |||||
Alarming Voice | ||||||
Battery Mode | ring one time per 4 seconds | |||||
Battery Low Capacity | ring one time per 1 seconds | |||||
Overload | ring one time per 0.5 second | |||||
Faults | continue to ring | |||||
Physical performance | ||||||
Standard Machine | Size D×W×H mm | 397×145×220 | 421×190×318 | 592×250×576 | ||
Weight(kg) | 13 | 26 | 28 | 81 | 83 | |
Long backup time machine | Size D×W×H mm | 397×145×220 | 421×190×318 | 592×250×576 | ||
Weight(kg) | 7 | 13 | 25 | 27 | ||
Environment | ||||||
Humidity | 20-90% RH @ 0-40°C (No condensation) | |||||
Noise | <45dB @ 1M | <55dB @1 M | <58dB @ 1M | |||
Control Management | ||||||
Smart RS-232 (optional USB) | Support Windows2000/2003/XP/Vista/2008/7, Linux, Unix and MAC | |||||
Optional SNMP | Support SNMP card for Remote Control |