1320kw used cummins engine assemble diesel generator -KTA50-GS8
Negotiable /Set
Min.Order:1 Set
Shenzhen Fudiankang Diesel Gensets Co., Ltd.
DescriptionTechnical parameters of Gen-Set:
Generator set | Open type | Silent type |
Model | FCG1320 | FCG1320S |
Engine model | KTA50-GS8 | |
Alternator | Engga,Marathon,Stamford | |
Prime power (kva/kw) | 1500kva/1200kw | |
Standby power ( kva/kw) | 1650kva/1320kw | |
Output voltage | 415/240 or 400/230 or 380/220 v | |
Power factor | COSΦ=0.8(lagging) | |
Phase/wires | 3 phase 4 wires | |
Fuel consumption @ 100%prime power | 309 L/h @ 100% prime power | |
Rated speed (r/min.) | 1500R.P.M ,50HZ | |
Dimension(L*W*H) | 5100*2150*2450mm | Canopy:40HQ |
Weigh (kgs) | 11400kgs | 14600kgs |
Noise level (at 7m) | 108dba | 80dba |
Technical parameters of Engine: | |||
Engine model & Origial | Cummins India KTA50-GS8 | ||
Engine power prime | 1287kw | ||
Cylinders | 16/V type,Four-stroke, turbocharged | ||
Bore*stroke(mm) | 159×159 | ||
Compression ratio | 14.9:1 | ||
displacement | 50.3L | ||
Aspiration | Turbocharged and low temperature aftercooled | ||
type of cooling | Close type cooling With fan & radiator | ||
Type of Governor | Electronic | ||
Filters system | Easy replacement type ,whole lubricating oil, Fuel filter and air filter, air filter for the paper core type. | ||
Muffler and exhaust pipe
| By using of industrial high performance muffler with flexible bellows flexible connected exhaust pipe , the generators can be reduced 15 ~ 20dBA Noise | ||
Start type | 24V DC start, start motor comes with built-in battery | ||
Technical parameters of Engine: | |||
Alternator Brand | Engga | Marathon | Stamford |
Alternator Model | EG450S-1200N | MX-1240-4 | PI734C |
KW POWER | 1200 KW,50hz 1500 RPM | ||
excited type | Brushless, self-excited(with auto voltage stability) | ||
Grade for rotor, stator loop. | H GRADE | ||
Protection Grade | IP21/IP22 | ||
Power quality | G3 Grade,GB/T2820 | ||
Rated Voltage | 415/240 or 400/230 or 380/220 v | ||
The Voltage Fluctuation | ≤0.5% | ||
Instantaneous Regulation of Voltage | +20%~-15% |
Technical parameters of Control Panel: digital and AMF | |
Details |
Brand: HK Harsen Model: GU620A Function: ·The controller has the following protection functions, such as Emergency halting Low accumulator alarming Over speed protecting Low oil voltage protecting 3 failure start alarming Start motor take-off Temperas halting protection
|
Warranty: one year or 1,000 operation hours, which reach first.
During this period, any quality problem about spare parts, can send the failed spare parts back to us for getting the fresh ones, except the parts from personal damage as well as the breakables.If big problem,Cummins worldwide after-sales work for the warranty,we can ask your market Cummins agent engineer go check the generator.
Standard :Each set of diesel together with a silencer, exhaust bellows; connecting cables of battery, lead-acid battery, toolbox, user’s manual, plastic rubber.document.
1. Testing conditions.
Standard Air Intake Temperature 25ºC
Air Intake Pressure 100kpa
Standard Light Diesel 0# or 10# Light diesel
Fuel Intake Temperature 40ºC
Air Intake Restriction 254mmHg
Exhaust Back Pressure 76mmHg
Lubricant Oil 15W40-CF4 Upgrade
2. Operation.
Continuous power: operate continuously for 24h in a day. 10% overload for
An hour is allowed in a 12 hours.
Standby power: this is used only when the civil power is off. Overload is not allowed.