Meanwell 600W 42V High Quality switching power supply/600w single output ac/dc power supply switching/600w power supplies 42v Supplier's Choice
USD $1 - $170 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
Original MEAN WELL
HEP-600-36
Input: 90 ~ 264VAC 127 ~ 373VDC
Output: 36V 16.7A
Safety standards: CE, CB, TUV, EMC
Warranty: 5 years warranty
MODEL | HEP-600-42 | |
OUTPUT | DC VOLTAGE | 42V |
| RATED CURRENT | 14.3A |
| RATED POWER | 600.6W |
| RIPPLE & NOISE (max.) Note.2 | 250mVp-p |
| VOLTAGE ADJ. RANGE | 35.7 ~ 44.1V |
| CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer |
|
| 7.1 ~ 14.3A |
| VOLTAGE TOLERANCE Note.3 | ±1.5% |
| LINE REGULATION | ±0.5% |
| LOAD REGULATION | ±0.5% |
| SETUP, RISE TIME Note.5 | 500ms, 80ms at full load 230VAC/115VAC |
| HOLD UP TIME (Typ.) | 15ms at full load 230VAC /115VAC |
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 373VDC |
| FREQUENCY RANGE | 47~63HZ |
| POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load |
| EFFICIENCY (Typ.) | 96% |
| AC CURRENT (Typ.) | 7A / 115VAC 3.3A / 230VAC |
| INRUSH CURRENT (Typ.) | COLD START 70A(twidth=1000 s measured at 50% Ipeak) at 230VAC |
| LEAKAGE CURRENT | <0.75mA / 240VAC |
PROTECTION | OVER Current | 105 ~ 125% |
|
| Protection type : Constant current limiting, recovers automatically after fault condition is removed |
| SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed |
| OVER VOLTAGE | 46 ~ 50V |
|
| Protection type : Shut down o/p voltage, re-power on to recover |
| OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover |
FUNCTION | REMOTE ON/OFF CONTROL | Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit |
| 5V STANDBY | 5VSB : 5V 0.5A ; tolerance ±5%, ripple : 100mVp-p(max.) |
ENVIRONMENT | WORKING TEMP. | -40 ~ +70℃(Refer to "Derating Curve") |
| WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
| STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH |
| TEMP. COEFFICIENT | ±0.03%/℃(0 ~ 60℃) |
| VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY
| SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC |
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A |
OTHERS | MTBF | 76.9K hrs min. MIL-HDBK-217F (25℃) |
| DIMENSION | 280*144*48.5mm (L*W*H) |
| PACKING | 3.9Kg; 4pcs/16.6Kg/0.9CUFT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 7. Refer to warranty statement. |