Meanwell HLG-600H-12 480W 12v Switching Power Supply 480w 40a led driver
USD $1 - $10 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | HLG-600H-12 | ||
OUTPUT | DC VOLTAGE | 12V | |
| CONSTANT CURRENT REGION Note.4 | 6 ~12V | |
| RATED CURRENT | 40A | |
| RATED POWER | 480W | |
| RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
| VOLTAGE ADJ. RANGE Note.6 | 10.2 ~ 12.6V | |
| CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer A type only | |
|
| 20~40A | |
| VOLTAGE TOLERANCE Note.3 | ±3.0% | |
| LINE REGULATION | ±0.5% | |
| LOAD REGULATION | ±2.0% | |
| SETUP. RISE TIME Note.8 | 500ms, 80ms at full load 230VAC /115VAC | |
| HOLD UP TIME (Typ.) | 15ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC | |
| FREQUENCY RANGE | 47~63HZ | |
| POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |
| TOTAL HARMONIC DISTORTION | THD<20% when output loading>=50% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
| EFFICIENCY (Typ.) | 230VAC | 92% |
|
| 277VAC | 92.5% |
| AC CURRENT (Typ.) | 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC | |
| INRUSH CURRENT (Typ.) | COLD START 70A(twidth=1000μs measured at 50% lpeak) at 230VAC | |
| LEAKAGE CURRENT | <0.75mA / 277VAC | |
PROTECTION | OVER CURRENT Note.4 | 95 ~ 108% | |
|
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |
| SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed | |
| OVER VOLTAGE | 13 ~ 16V | |
|
| Protection type : Shut down o/p voltage, re-power on to recover | |
| OVER TEMPERATURE | 105℃±5℃(TSW1) | |
|
| Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |
FUNCTION | REMOTE ON/OFF CONTROL | Power on: “Hi”>2~5V or (Open circuit) Power off: :Low”<0~0.5V or (Short circuit) | |
| 5V STANDY | 5VSB : 5V 0.5A ; tolerance ±5%, ripple : 100mVp-p(max.) | |
ENVIRONMENT | WORKING TEMP. | -40 ~ +70℃(Refer to "Derating Curve") | |
| WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
| STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |
| TEMP. COEFFICIENT | ±0.03%/℃(0 ~ 60℃) | |
| VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS Note.7 | UL8750, CSA C22.2 No. 250.13-12, EN61347-1, EN61347-2-13 independent,IP65 or IP67 approved | |
| WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | |
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |
| EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≥50% load) ; EN61000-3-3 | |
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A | |
QTHERS | MTBF | 76.9K hrs min. MIL-HDBK-217F (25℃) | |
| DIMENSION | 280*144*48.5mm (L*W*H) | |
| PACKING | 3.9Kg;4pcs/16.6Kg/0.9CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 50%~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. A type only. 7. Safety and EMC design refer to EN60598-1, subject CNS15233, GB7000.1, FCC part18. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 10. Refer to warranty statement |