active power filter for internet data center
Technical advantage
Can choose certain number harmonic to compensate
harmonic,reactive power,unbalanced load three compensation mode
work efficiency >97% ,low power loss
Double DSP •Three multilevel inverter topology
Modular design,safety and stability
4.3-inch touch screen LCD monitor unit
Small size,rack/wall mounted type,save space
model
HTQF 3L-0.4/xxAR 3P3L HTQF 4L-0.4/xxAR 3P 4L | ||
model | 30A | 50A |
Wiring method | Three phase three line | |
Rating voltage. V | 400....-20/+15% | |
Rating frequency . Hz | 50/60 | |
Rating compensation current. A | 30 | 50 |
Rating compensation capacity kvar | 20 | 33 |
Weight kg | 28 | 28 |
cabinet | 19inch standard rack type or wall mounted type | |
installation | Rack or wall mount | |
dimension(width*depth*height mm) | 440*630*176 | |
Current detection method | Source current detection/load current detection . optional(indicate when placing order) | |
color | RAL9004 black (can be customized) | |
Protection level | IP3X(can be customized) | |
Into line way | Up or back |
technical parameter
model | HTQF.3L-0.4/xxAR 3P3L | HTQF.4L-0.4/xxAR 3P4L |
Wiring | 3phase 3line | 3phase 4line |
features | ||
| Apply to 3P3L system, filter was connected among three phase of power grid, it is suited to power system with or without neutral line, it can filter none-zero frequency harmonics, compensate reactive power and phase unbalanced.. | Apply to 3P4L system, can filter the harmonic through phase and neutral line, include zero sequence harmonic |
Single compensation current | 30A | 30A |
50A | 50A | |
input | ||
voltage | 400V.....-20/+15% | 400V.....-20/+15% |
frequency | 50/60Hz ±5% | 50/60Hz ±5% |
Performance index
| ||
Filter capacity | More than 97% | More than 97% |
Filter range | 2~50th | 2~50th |
Filter effect set | Can separate set each harmonic | Can separate set each harmonic |
Response time | Transient response<0.1ms, complete response<20ms | Transient response<0.1ms, complete response<20ms |
Neutral line compensate ability | - | 3 times in line RMS current |
Reactive power compensation | Setting range of power factor is from inductive0.6 to capacitive 0.6 | Setting range of power factor is from inductive0.6 to capacitive 0.6 |
Balance compensation | Programmable balance of power | Programmable balance power of phase and phase or phase and neutral line |
Special technology | Three multilevel topology,high efficiency,loss power loss | Three multilevel topology,high efficiency,loss power loss |
Overload protection | Automatic current limiting when 100% rating output | Automatic current limiting when 100% rating output |
Power loss | ≤3% rated compensation capacity | ≤3% rated compensation capacity |
CT requirements | 3set,0.2magnitude or more,secondary 5A | 3set,0.2magnitude or more,secondary 5A |
Current detection means | Source current detection or load current detection | Source current detection or load current detection |