harmonic filter unit
Negotiable /Set
Min.Order:1 Set
Shandong Hoteam Technology Group Co., Ltd.
harmonic filter unit
HTQF xL-0.4 technical parameters
model | HTQF/3L-0.4/xxxA 3P3L | HTQF/4L-0.4/xxxA 3P4L |
feature | ||
| Apply to 3P3L system | Apply to 3P4L system, can realize neutral line filter |
Compensation current of each cabinet | 30A | 30A |
50A | 50A | |
75A | 75A | |
100A | 100A | |
150A | 150A | |
200A | 200A | |
250A | 250A | |
300A | 300A | |
400A | 400A | |
500A |
| |
600A |
| |
input | ||
voltage | 400 —15/+10% | 400 —15+10% |
frequency | 50/60HZ ±5% | 50/60HZ ±5% |
Performance index | ||
Filter capacity | Can be more than 97% | Can be more than 97% |
Filter range | 2~50th harmonic | 2~50th harmonic |
Response time | Transient response<0.1ms, complete response<20ms | Transient response<0.1ms, complete response<20ms |
Neutral line compensate ability | — | 3 times in line RMS current |
Reactive power compensation | Setting range of power factor is from inductive0.6 to capacitive 0.6 | Setting range of power factor is from inductive0.6 to capacitive 0.6 |
Balance compensation | Programmable balance of power
| Programmable balance power of phase and phase or phase and neutral line |
Overload protection | Automatic current limiting when 100% rating output | Automatic current limiting when 100% rating output |
Power loss | ≤3% rated compensation capacity | ≤3% rated compensation capacity |
CT requirements | 3set,0.2magnitude or more,secondary 5A | 3set,0.2magnitude or more,secondary 5A |
Current detection means | Source current detection or load current detection | Source current detection or load current detection |
Display and interface | ||
language | English/Chinese | English/Chinese |
Operating button | Start/stop,reset,menu,confirm,fluctuation function keys and so on | Start/stop,reset,menu,confirm,fluctuation function keys and so on |
Indicator light | green:normal operation | green:normal operation |
orange:over current/overload operation | orange:over current/overload operation | |
red:machine halt or alarm | red:machine halt or alarm | |
Communication interface | RS—485 | RS—485 |
Communication protocol | MODBUS(RTU) | MODBUS(RTU) |
digit I/O | 4 digital input,2 digital alarm | 4 digital input,2 digital alarm |
configuration | ||
Unit operation | allow | allow |
Parallel operation | 10 sets at most | 10 sets at most |
IP | IP3X,(higher IP pls contact manufactuer) | IP3X,(higher IP pls contact manufactuer) |
Color | RAL7035(light gray), can be customized according to use requirements | RAL7035(light gray),can be customized according to use requirements |
Environment condition | ||
temperature | —10~40°C | —10~40°C |
Storage temperature | —25~55°C | —25~55°C |
Relative humidity | Max 95%RH(no condensation) | Max 95%RH(no condensation) |
altitude | 1000m | 1000m |
Main applications | ||
| Suitable for industrial big capacity load, such as rectifier, frequency converter, UPS, IF furnace, A rc furnace and so on. | Suitable to commercial buildings, such as energy saving lamp, computer, UPS and so on which may product 3rd harmonic. |
Special Features
Higher efficiency, lower loss
More functions, more modes
More stable, more reliable
Higher power density, easier installation and maintenance
OEM,ODM and customized service, after-sale service, technial traing support and so on
1. What is voltage level? 380V, 440V, 480V,600V,690V
2. Is it can solve harmonic, low power factor and three phase un-balance problems at the same time? Yes, it can.
3. what is the delivery time? usually need about 30 days as it is customized product