2400mah portable battery charger for samsung galaxy s3 wholesaler
USD $3 - $5 /Piece
Min.Order:1 Piece
Ningbo Keqiang Battery Co., Ltd.
2400mah portable battery charger for samsung galaxy s3 wholesaler
Battery Capacity | 1400mah,1800mah,2000mah,2200mah,2600mah,3000mah |
Battery Cell Type | Li-ion battery cell |
Rated Input | 5.0V/1000mAh |
Rated Output | 5.0V/1000mAh |
Self-Charging Time | 2-3 hours |
Fully Charging Iphone | 1-2 times ( Iphone battery 1420mAh) |
Recharge Cycles | Charge to 100% Up to 500 times |
LED Indicators | 1 battery capacity level LED indicators |
LED Torch | YES |
Protection Functions | Built-in protection functions for short circuit, over charge/discharge; |
Attached Connectors | Micro Mini USB |
Devices Supported | Mobile phones, MP3 players, MP4 players, PDAs, digital cameras, handheld game consoles, Bluetooth devices and so on. |
1. Power bank *1pcs
2. Manual
3. USB cable & connectors (option accessories please see form below)
4. Color box
Shipping:
1. Express: DHL, UPS, Fedex, EMS,TNT etc.
2. Airway
3. Seaways.
1, one year warranty for each piece
2, strict quality control inspection before shipment
3, real capacity with high battery conversion efficiency (over 80%)
4, shockproof & high quality blister packing to protect the item from damaging during shipment
5, OEM design & OEM packing welcome
6, Unique Patent Design
7, Strong product abiliby,60,000 square meters factory
8, Top 10 Global E-business Company of Alibaba
9, Service online,reply to you within 8 hours
KETRON KETRON was founded in 1990 and has been dedicating in assemled battery. Twenty-year technological accumulation makes us have the ability of good industrial resource integration and builds top-ranking product quality of KETRON. It is used as purpose of enterprice to provide clients fast and responsible service, ensure every client’s confidence on mobile power of KETRON with powerful service management and establish KETRON into high-quality brank of global battery industry carefully.
KETRON ensures each of products in the market only after strict multiple tests and tries its best to reduce maintenance opportunity based on quality philosophy of “quality service is the largest one”.
We selcect the high-quality components supplier,inspect each of stored equipments strictly and assure quality of KETRON at the sourse.
Each of our products stands up standard performance examination and operation of every technical process is in conformity with standard system of ISO9001.
Notices for Use of IPhone External Battery
1. Output voltage range of external battery. Although some devices have USB interfaces, they also need
to be charged by your external battery. However, you should pay attention to the input voltage range of
your devices. Output voltage range of universal mobile power is 5.3 to 0.5V. If the input voltage range
your device requires is not within the output voltage of mobile power, then, it is recommended that you do
not use the mobile power supply for your device, to ensure the life of your mobile external battery.
2. The USB interface must match the devices'. Because various USB have different data cables for
devices, in order to properly use external battery for your device, please use the matching USB data
interface.
INSPECTION PROTOCOL AND QA FOR LITHIUM BATTERY
No. | unit | min | type | max | remark | |
charge | ℃ | 0 | 25 | 45 | ||
discharge | ℃ | -20 | 25 | 65 | ||
storage | ℃ | -20 | 25 | 45 | 1 month | |
℃ | -20 | 25 | 35 | 6 months |
Before storage, batteries should be charged to 40%-65% of full capacity
Characteristics testing:
item | test method | Requirements |
Charging/Cut-off Voltage | 4.20±0.01V | |
Discharge/Cut-off Voltage | 3.00±0.01V | |
Standard Charge | Charge the battery at constant current of 0.2C to reach 4.2V. Then charge the battery at constant 4.2V voltage until , the charging current decreasing to 0.01C. | Charging time≤8h |
Standard Discharge | After the standard charging,rest for 1 hour then discharge, to 3.0V 0.2c | |
Rate Discharge | After the standard charging,rest for 1 hour then discharge, to 3.0V 0.5C | Discharging time≥102Min |
High Temperature Characteristics | Fully charging, store them at (55±2)℃ for 2 hours, then discharge to 3.0V @0.5C | Discharging time ≥102 Min , No transform, no explosion,no fire,no leakage |
Low Temperature Characteristics | Full charging, store them at (-10±2)℃ for 16-24 hours, then discharge to 3.0V @0.2C | Discharging time ≥255 Min, No transform, no explosion,no fire,no leakage |
Capacity retention | Fully charging, store them at (20±2)℃ for 28 days, then discharge to 3.0V 0.2C | Discharging time ≥255 Min, No transform, no explosion,no fire,no leakage |
Cycle Life 25℃ | Charge the battery @0.5C to reach 4.2V. Then charge the, battery at constant 4.2V voltage until the charging current, decreasing to 0.01C. Rest for 10 min. discharge to 3.0V 0.5C and rest for 10 min. Continue the charge/discharge cycles until discharge capacity lower than 80% of rated capacity | Cycle life ≥500 |
Storage | Charge the battery to 40%~65% of its rated capacity using, standard charging mode, then keep it in an 20℃±5℃, humidity 45%~85% room for 12 months. Discharge it 0.2C until voltage down to 3.0V | Discharge time ≥240Min |
Environment Characteristics:
Item | Testing Method | Requirements |
Hot & humidity testing | Full charging, store it at 40±2℃ with 90%~95RH% for 48 hours. Then put the battery at room temperature 20±2℃ for 2 hours. Then discharge to 3.0V 0.5C | Discharging time ≥72 Min no transform, No erosion, no explosion,no fire,no leakage |
Vibration | After Standard Charging,fixed the battery to vibration table,then subjected to vibration test for 30 minutes per axis of XYZ axes | No explosion,no fire, no leakage. Voltage≥3.7V. |
Shock test | After Standard Charging,test condition Acceleration :100m/s2 Crash time per min: 40-80 times, Pulse lasting time : 16ms , Shock times : 1000±10times | No explosion, no fire, no leakage. Voltage≥3.7V. |
Drop Test | After standard charging , drop the battery from 100cm, height onto a 18mm~20mm thick hardwood. Two sides of X,Y,Z directions each (total 6 times) After the drop test, discharge the battery 0.5C to 3.0V Then charge it 0.5C to full capacity. Continue the test within 3 times the battery should reach the target once | Discharging time ≥102 Min No erosion, no explosion,no fire,no leakage |
Safety Performance
Overcharge protection test | After standard charging. Apply a 7.4V stable Voltage and 1C stable current to the battery for 8 hours | No fire, no explosion |
Over discharge protection test | After discharged to the cut-off voltage,the battery shall be subjected to a short-circuit condition with a load of resistance less than 30Ω for 24 hours | No fire, no explosion |
Short circuiting protection test | After standard charging,the battery shall be subjected to a short-circuit condition with a wire of resistance less than 100mΩ for 1 hour. Cut off the circuit, Charge the battery with constant current at 1.0C for 5s | No fire, no explosion, Voltage≥3.7V |
Impact Test | After standard charge,Place the battery on a flat surface. A 9.1 kg article is to be dropped from a height of 100cm onto the sample. The battery is allowed to transform | No fire, no explosion |
Heating Test | After standard charging,a battery is to be heated in an oven convection or circulating air oven. The temperature of the oven is to be raised at a rate of 5±2℃/min to a temperature of 130±2℃ and last for 30 minutes. | No fire, no explosion |
Over charge | After standard charging, put the battery in fume hood. Add constant voltage & current 4.8V 3C to the battery. Charging it until the battery reaches 4.8V, charging current decreases to almost 0A. Record the temperature curve of the battery. When the battery temperature decreases to about 10℃ lower after reaching the peak temperature. End the test. This test is performed without PCM | No fire, no explosion |
Short circuiting test | After standard charging, put the battery in fume hood. Connect the Negative Pole and Positive pole directly. (the wire’s resistance should below 50mΩ. Record the battery’s temperature curve during the test. When the battery temperature decreases to about 10℃ lower after reaching the peak temperature. End the test. This test is performed without PCM | No fire, no explosion |
Contact :Kobe chen Cellphone :+86 13165939787 skype:powerbank 1990