flow meter LUGB for sea water sewage

flow meter LUGB for sea water sewage

USD $389 - $440 /Set

Min.Order:1 Set

Supply Ability:
200 Set / Sets per Month
Port:
tianjin china
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Tianjin, China
Brand Name:
SURE
Model Number:
LUGB-DN50-I-A

Tianjin Sure Instrument Science & Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Tianjin China
Main Products: Flow Meter ,Turbine Flow Meter Series ,Steam flow meter ,Ultrasonic flow meter ,Oil flow meter

Product Details

Specifications

We manufacture Digital Vortex Flow Meter, Pipe size is from 15mm to 500mm Accuracy is 0.5% or1.0%

 
Product Description

We manufacture Digital Vortex Flow Meter, Pipe size is from 15mm to 500mm Accuracy is ± 0.5% or ± 1.0% Max pressure ≤ 4.0Mpa, Medium temperature 50— +350º C, Explosion-proof is ExdIIBT4/ Exib IICT4, Output signal: 4-20mA; RS485; HART. Our Digital Vortex Flow Meter is widely used for Water Sewage seawater, Water distribution, Power Plants cooling water, Boiler feed water, Mining leaching and return flows, Liquid petroleum products, Pipeline leak detection, Energy management systems Process plant water and chemicals.


Specification

DVFM-1000

Pipe size

DN15 to DN350 (Other pipeline, please by negotiation )
Accuracy
± 1.0% repeat better than 0.33%

± 0.5% repeat better than 0.15%

Max pressure

≤ 4.0Mpa (40bar)

Medium temperature

(-50— +250)º C, (-50— +350)º C

Display method

128× 64 LCD display

Protection class

IP65, IP67

Environment temperature

-30— +70º C (-20— +60º C for LCD display)

Environment

-40~+55º C, RH: 5%~90% atmospheric pressure 86~106KPa

Explosion-proof

ExdIIBT4/ ExibIICT4

Three wire output 

Power supply: 12~24VDC, if don’ t need any signal output, can be as low as 6VDC; if powered by back up battery: 2#3.6V

Output method: Pulse signal output; three wire 4~20mA with linear calibration; RS485 communication is optional

Two wire output 

Power supply: 15~24VDC

Output method: 4~20mA with linear calibration is optional; Optical isolation without amendment the original pulse output  (Need an additional power supply)

HART communication: Support 14 commands of the total 57 ordinary commands

Contact Supplier

Mr. Yanbeen Deng Overseas Sales Manag Chat Now
Telephone
86-22-58781425
Mobile
86 186 0227 0114
Fax
86-22-27984210
Address
Outer ring industrial area 12, Fujin Road, Zhongbei industrial park(Northern park) Tianjin

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Flow Measuring Instruments > Flow Meters
Categories
Hi~