Fixed Split Ultrasonic Flow Meter
USD $500 - $2,000 /Piece
Min.Order:1 Piece
Tianjin Sure Instrument Science & Technology Co., Ltd.
[ Feature ]
l High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
l Wide measuring range
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm
l High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
l Strong Anti-interference
Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
l Powerful Recording Function
Automatically record the following data:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow rate of the last 64 times of power on and off events
3. The working status of the last 32 days
[ Main Feature ]
Item | Performance and Parameter | |
Main Unit
| Principle | transit-time ultrasonic flowmeter |
Accuracy | 1% | |
Display | 2 line x 20 character LCD with backlight | |
Operation | Support 16 key light touch keyboard and the Simulation keyboard software | |
Signal Output | Isolation RS-485 output; 1 channel isolation OCT output; 1 channel isolation 4-20mA output (two-wire system) | |
Signal Input | Three channel 4—20Am analog signal input | |
Data interface | Insulate RS485 serial interface, upgrade the flew meter software by computer, support the MODBUS, METER-BUS etc. | |
Pipe Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed. |
Pipe Diameter | 15---6000mm | |
Straight length pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. | |
Measuring Medium | Type of Liquid | Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, acids, etc.); Plant effluent; Beverage, liquid food; Ultra-pure liquids; Solvents and other liquids |
Temperature | Standard Transducer: -30--90°C; High-temperature transducer: -30--140°C | |
Turbidity | 10000ppm and less than bubble | |
Flow rate | 0--±30 m/s | |
Flow Direction | Measuring two (plus-minis) direction of flow rate | |
Working Environment | Temperature
| Main Unit: -20--60°C |
Flow transducer: -40--160°C; | ||
Humidity | Main Unit: 85% RH | |
Power Supply | DC24V /AC85-264V |