LWQ Gas Turbine Flow Meter CE certification
USD $399 - $600 /Set
Min.Order:1 Set
Tianjin Sure Instrument Science & Technology Co., Ltd.
1.0 SPECIFICATIONS
Performance |
|
|
|
|
|
|
| ||
Repeatability: | ±0.2% |
|
|
|
|
| |||
Accuracy: | Standard: ±1% of reading; |
|
| ||||||
| Optional: ±0.5% of reading |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Wetted Components |
|
|
|
|
|
| |||
Housing: |
| Standard - 304 Stainless Steel |
|
| |||||
| Optional - 316 Stainless Steel |
|
| ||||||
Bearings and Shaft: | Tungsten Carbide |
|
|
| |||||
Rotor: | Standard - 2Cr13 Stainless Steel |
|
| ||||||
| (Optional Alloy CD4Mcu) |
| |||||||
Retaining Rings: | 316 Stainless Steel |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
Output Signal: (Where applicable) |
|
|
|
| |||||
Sensor: | Pulse signal (Low Level: ≤0.8V; High Level: ≥8V) | ||||||||
Transmitter: | 4 to 20 mA DC current signal |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Signal Transmission Distance: ≤1,000 m |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Electrical Connections: | |||||||||
Basic Type: | Hausman Connector or three-core cable |
| |||||||
Explosion Proof Type: | ISO M20×1.5 Female |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
Explosion Proof Level: | |||||||||
Standard: | None |
|
|
|
|
| |||
Optional: | ExdIIBT6/ExiaIIBT4 |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
Protection Level: | IP65 |
|
|
|
|
|