Hot sale water cooling industrial chiller
USD $1 - $15,000 /Set
Min.Order:1 Set
Wuxi Guanya Refrigeration Tech Co., Ltd.
Typical Applications:
Semiconductor Manufacturing Device Cooling:
Single chip cleaning, printing machine, automatic clamp installation equipment, spraying equipment, ion plating equipment, etching device, single chip processing device, slicing machine, packaging machine, the temperature of the developer management, exposure device, magnetic part of the heating device, etc.
Laser Equipment Cooling:
Laser processing,heating part of the welding machine, laser marking device, chemical reaction plant, carbon dioxide laser processing machine, etc.
Other Industries Cooling:
Plasma welding, automatic packaging machine, mold cooling, washing machine, gold-plated groove, resin molding machine, precision grinding machine, injection molding machine of molding parts, etc.
Analysis Of Testing Machine Cooling:
Electronic microscope, ICP lighting light source part of the spectrum analysis device, heating part of the spectrophotometer, X-ray analytical device of heat source, automatic pulse heating part of the banner, the light source of atomic absorption spectrophotometer, etc.
CNC machine, machining center cooling of cooling medium.
1.Temperature of heat transfer fluid can be adjustable.
2.Adopt ASPERA,DANFOSS,MANEUROP,COPELAND etc. Brand compressor,stable performance and can work continuously.
3.Human design,more convenient and flexible.
4.Microcomputer temperature controller,temperature figures display,adjustable unit is 0.1℃, temperature range is 7℃~30℃.
5.Use hot gas bypass, save energy and improve the control precision.
6.A variety of fault alarm (overtemperature alarm, high pressure alarm, sensor alarm,compressor overheat alarm)
7.Power on delay protection.
8.All parts are safety grounding.
9.High-performance circulating pump, can guarantee 24 hours continuously running a day.
Technical Parameters:
Model | FL-3500 FL-3500H | FL-5000 FL-5000H | FL-10000W FL-10000WH | FL-16000W FL-1000WH | FL-24000W FL-24000WH | FL-36000W FL-36000H | |
Temperature Range | Standard FL-series temperature range 5℃~35℃ (only with cooling function) | ||||||
FL with H-series temperature range 5℃~50℃ (both with cooling function and heating performance) | |||||||
Temp. control | ASET multifunctional controller | ||||||
Temp. control optional | Heat-conducting medium outlet temp. control | ||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||||
Temperature feedback | Heat-conducting medium temperature feedback PT100 | ||||||
Cooling capacity | 20℃ | 35kW | 50kW | 100kW | 160kW | 240kW | 360kW |
10℃ | 28kW | 40kW | 80kW | 128kW | 192kW | 288kW | |
Cooling capactiy (H series) | 10℃ | 35kW | 50kW | 100kW | 160kW | 240kW | 360kW |
20℃ | 28kW | 40kW | 80kW | 128kW | 192kW | 288kW | |
45℃ | 17kW | 24kW | 48kW | 77kW | 115kW | 173kW | |
Circulation pump | 9m3/h 2.5bar max | 15m3/h 2.5bar max | 15m3/h 2.5bar max | 25m3/h 2.5bar max | 25m3/h 2.5bar max | 35m3/h 2.5bar max | |
Capacity of liquid storage | 200L | 400L | 650L | 1000L | 1200L | 1800L | |
Compressor | Copeland | Copeland | Copeland | Copeland | Copeland | Copeland | |
Evaporator | Plate heat exchanger | ||||||
Operation Panel | Display setting temperature and testing temperature;Touch key display | ||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||
Refrigerant | R-410A | ||||||
Connection size | DN-25 | DN40 | DN40 | DN40 | DN40 | DN-50 | |
Dimension cm | 950*1700*1700 | 1100*2000*2000 | 1800*1200*1750 | 2050*1450*1750 | 2350*1450*1750 | 2450*1450*2050 | |
Weight (air-cooled) | 800kg | 1000kg | 1350kg | 1500kg | 1800kg | 2400kg | |
Power | AC380V 50HZ 12kW (max) | AC380V 50HZ 18kW (max) | AC380V 50HZ 26kW (max) | AC380V 50HZ 43kW (max) | AC380V 50HZ 63kW (max) | AC380V 50HZ 92kW (max) | |
Case material | Cold rolled steel | ||||||
Optional | Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. | ||||||
Optional | SUS304 material | ||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase | ||||||
Remarks | Can make the bigger capacity of water storage as required. | ||||||
Optional | Optional outside touch screen display controller (separated), the communication line distance is 10 meter. |
Development history
2006 Start production of refrigeration and heating system .
2008 The first generation of refrigeration and dynamic temperature control system.
2009 Developed the second generation of refrigeration and heating thermostat.
2010 Established WUXI GUANYA REFRIGERATION TECHNOLOGY CO., LTD.
2012 Single compressor having multiple circulation systems is applied SUNDI and LT series.
2014 Developed with large capacity of ultra-low temperature freezer
2016 low temperature freezer, plate freezer into the market
Factory online visiting