AC/DC hs code power supply
USD $1 - $1,000 /Piece
Min.Order:1 Piece
Chengdu Lunyee Imp. & Exp. Co., Ltd.
AC/DC hs code power supply
Specifications
1. Low price and high reliability
2. 105 output capacitor
3. AC input power suitable for the world
4. High efficiency and low operation temperature
5. Soft-start current can reduce the AC input impact effectively
6. With short-circuit and overload protection
7. Compact size, light weight
8. 100% full-load burning test
9. Installed with EMI filter, minimum wave
Model | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
Specification | ||||||||
DC output voltage | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
Output voltage error (Note2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output current rage | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
Wave and noise(Note3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability(Note5) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 99.9W | 96W |
Efficiency | 70% | 78% | 80% | 81% | 81% | 84% | 84% | 84% |
Adjustable range for DC voltage | 2.85-3.3V | 4.75-5.5V | 6.75-8.25V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 26-32V | 43.2-52.8V |
AC input voltage range | 85132VAC/180264VACselected by switch4763Hz;255-370VDC | |||||||
Input current | 2.4A/115V 1.2A/230V | |||||||
AC impulse current | Cold-start current 30A/115V 60A/230V | |||||||
Leakage current | <1mA/240VAC | |||||||
Overload protection | 105%150% TypePULSING HICCUP SHUTDOWN Reset: auto recovery | |||||||
Temperature coefficient | ±0.03%(050) | |||||||
Setup rise hold up time | 200ms,100ms,30ms | |||||||
Vibration | 10500Hz,2G 10min./1cycle,Period for 60min,Each axes | |||||||
Withstand voltage | Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | |||||||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms | |||||||
Working temperature and humidity | -10+60,20%90%RH | |||||||
Store temperature and humidity | -20+85,10%95RH | |||||||
Overall dimension | 199*98*38mm | |||||||
Weight | 0.5Kgs | |||||||
Safety standards | Meet UL 1012 requirement(Not apply for the mark) | |||||||
EMC standards | Meet FCC Part 15J Conduction Class B | |||||||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity 2.Error,include the setting error, line stability and load stability.(Note:5) 3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5.Load stability test: The load is from 0% to 100%,others 60%. 6.C2311must be knocked down. |
pls feel free to inform us your request ,qty and other informations to get our price and leading time!