Specifications
1. Loose-tube layer-stranded2. Steel-plastic laminated tape
3. Steel wire armored
GYXTC8S Self-supporting Aerial Optical Cable
Technical Characteristics
♦ Fiber count: 2~96
♦ Low loss, low dispersion
♦ Proper design and precise excess length control and cabling process offers cable superior mechanical and environmental properties
♦ Steel wire armor and steel tape armor enhance the cable's anti-bending and side pressure resisting capability, and prevent it from gun and redent
♦ Small size, light weight, self-supporting
Performance
♦ Applicable to long distance, inter-exchange communication, CATV, computer network transmission system, etc.
♦ Minimum bend radius: static 10D, Dynamic 20D
♦ Operation temperature: -40 ~ +70
2. Cable Specification
2.1 Cable cross-section
2.2 Fiber color code
No. | 1 | 2 | 3 | 4 | 5 | 6 |
Color | Blue | White | Yellow | Green | Gray | Red |
No. | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Orange | Black | Pink | Violet | Brown | Aqua |
3. Fiber Properties
3.1 The properties of single mode optical fiber (ITU-T Rec. G.652D or G657A)
4. Characteristic of Optical Cable
4.1 Cable bending radius:
10 x cable diameter (during operation)
20 x cable diameter (during installation)
4.2 Temperature range
Operating temperature range | -40oC to +60oC |
Storage / Transport temperature range | -50oC to +70oC |
Installation temperature range | -20oC to +50oC |
4.3 Cable structure and parameter
Fiber number | Tube Diameter | Messenger strand steel wire diameter | Sheath thickness (nominal*) | Diameter W*H (Nominal*) | Weight (Approx.) |
mm | mm | mm | mm | kg/km | |
12 | 3.0 | 3.0 (1.0mm*7) | 1.5 | 7.3*14.3 | 116 |
24 | 3.6 | 3.0 (1.0mm*7) | 1.5 | 7.9*14.9 | 125 |
4.4 Main mechanical & environmental characteristics test
1 | Tensile Strength | As per IEC 794-1-E1 |
2 | Crush Test | As per IEC 60794-1-E3 |
3 | Impact Test | As pe IEC 60794-1-E4 |
4 | Repeated Bending | As pe IEC 60794-1-E6. |
5 | Torsion | As pe IEC 60794-1-E7 |
6 | Water Penetration | As pe IEC 60794-1-F5B |
7 | Temperature Cycling | As pe IEC 60794-1-F1 |
8 | Compound Flow | As pe IEC 60794-1-E14 |
9 | Sheath High Voltage Test | - No sheath breakdown @ 9t KV |
5. Production Flow
6. Workshop
7. Quality Management
8. Certificate
Company Profile