DK series(Specification)--Flexible current probe, used with oscilloscopes, recorders or data loggers

  flexible current probe for  hantek oscilloscope DK-0700

 

 
Product Description

  

 

Please refer the datas to the matched model:

 

 

Type

Sensitivity

 mV/A

Peak-Peak

Current(A)

Min. Current

   ( A)    

Noise

(mV Pk-Pk)

Bandwidth

(3db)

Accuracy

DK-Mini070

100

70

0.5

5

45Hz-4/8MHz

1%+2mV

DK-Mini140

50

140

1.0

5

45Hz-4/8MHz

1%+2mV

DK-Mini350

20

350

2.5

5

45Hz-4/8MHz

1%+2mV

DK-0700

10

700

5.0

5

5Hz-6/10MHz

1%+2mV

DK-1400

5

1400

10

5

5Hz-15MHz

1%+2mV

DK-3500

2

3500

25

5

5Hz-15MHz

1%+2mV

DK-7000

1

7000

50

5

5Hz-15MHz

1%+2mV

DK-14000

0.5

14000

100

5

5Hz-15MHz

1%+2mV

DK-35000

0.2

35000

200

5

5Hz-15MHz

1%+2mV

DK-70000

0.1

70000

200

5

5Hz-15MHz

1%+2mV

DK-140000

0.05

140000

200

5

5Hz-15MHz

1%+2mV

DK-350000

0.02

350000

1000

5

5Hz-15MHz

1%+2mV

 

 


Coil circumference:100,200 or 1000mm

Coil cross section(max): 3Kv(Standard)

Temperature range: -20°C-100°C

Cable length(from box to coil):2m or 4m

Power supply: DC supply adaptor or 6-9v or 4 batteries

Integrator box dimension: H=160mm,W=80mm,D=28mm

Coil cross section(max):2mm-14mm(with sleeve)

Output socket:BNC

 

DK flexible current probes Circumference/Diameter of the coil option:

 

 

Diameter(mm)

2.5

3.5

3.5

5.5

5.5

8.0

8.0

8.0

Circumference(mm)

100

200

300

300

500

500

700

1000

 

 

 
Packaging & Shipping

  

 

Standard packing:

 

flexible current probe for hantek oscilloscope DK-0700flexible current probe for hantek oscilloscope DK-0700

 

flexible current probe for hantek oscilloscope DK-0700

Contact Supplier

Ms. Jasmine Chao manager Chat Now
Telephone
86-20-61038868
Mobile
8613710851435
Fax
86-20-61038838
Address
Room B208-B211, Creative Center, No. 69, Guangpu West Road, Science City, Development Zone Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Oscilloscopes
Categories
Hi~