Type MP-Gc Mining Cable Cu/Epr/CPE 3/C 5kv ICEA S-75-381 NEMA WC-58
USD $1 - $5 /Inch
Min.Order:500 Inches
300mm2 mining cable Cu/XLPE/PVC 3/C 5kv ICEA S-75-381/NEMA WC-58
Type MP-Gc Mining Cable Cu/XLPE/PVC 3/C 8kv ICEA S-75-381/NEMA WC-58
Type MP-Gc MineCable Cu/XLPE/PVC 3/C 15kv ICEA S-75-381/NEMA WC-58
Type Shd-Gc Mining Cable Cu/Epr/TPU 3/C 15kv ICEA S-75-381/NEMA WC-58
Type Shd-Pcg AWG 1/0 mining cable Cu/Epr/CPE 3/C 5kv ICEA S-75-381
N2XS2Y, 12/20 kV, Power Cable, 1/C, Cu/XLPE/Cws/PE (HD 620 10C/VDE 0276-620)
Type MP-GC, Mining Cable, Cu/EPR/CPE, 3/C, 5KV (ICEA S-75-381/NEMA WC-58)
Features
True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
Application
High voltage distribution intended for permanent installations.
Suitable for underground mining and boreholes.
Can be used in aerial nstallations, ducts or direct burial.
Standards
ICEA S-75-381/NEMA WC-58
Portable and Power Feeder Cables for Use in Mines and Similar Applications.
Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations
Normal: 90 °C Emergency: 130 °C Short Circuit: 250 °C
Engineering Information
1. Phase, Grounding and Ground Check Conductors: Soft or annealed uncoated copper compressed Class B stranding, or unilay-compressed per ASTM B8. On request, compacted strand. Sizes: 6 AWG up to 500 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed copper tape, 2.5 mil minimum thickness, 10% minimum overlap. Phase ID: Color printed on the extruded conducting layer, BL, WH, RE.
6. Ground Check: Thermosetting insulation yellow colored for identification.
7. Assembly: Phase conductors cabled with the ground check between the BL and WH phase conductors, two grounding conductors in inmate contact with the shields, placed on the remaining interstices, suitable fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound. On request, PVC jacket.
Conductor Size | Number of Strands | Size of Each Strand | Nominal Insulation Thickness | Ground Conductor Size | Maximum Overall Diameter | Approximate Total Weight |
AWG or kcmil | AWG | mil | AWG | in | lb/kft | |
6 | 7 | 90 | 10 | 110 | 1.3 | 1015 |
4 | 7 | 90 | 8 | 110 | 1.4 | 1277 |
2 | 7 | 90 | 6 | 110 | 1.6 | 1673 |
1 | 19 | 90 | 5 | 110 | 1.7 | 1949 |
1/0 | 19 | 90 | 4 | 110 | 1.8 | 2278 |
2/0 | 19 | 90 | 3 | 110 | 1.9 | 2789 |
3/0 | 19 | 90 | 2 | 140 | 2 | 3300 |
4/0 | 19 | 90 | 1 | 140 | 2.2 | 3924 |
250 | 37 | 90 | 1/0 | 140 | 2.3 | 4502 |
300 | 37 | 90 | 1/0 | 140 | 2.4 | 5100 |
350 | 37 | 90 | 2/0 | 140 | 2.5 | 5853 |
500 | 37 | 90 | 4/0 | 140 | 2.9 | 8111 |
We are glad to offer free samples for testing, please feel free to talk with us.
1. Are you a manufacturer?
Yes, we are a manufacturer. Jiangsu Baoan Cable Co., Ltd. Is factory. Mainly responsible for the import and export business.
2. What are your main products?
Our main products are ACSR, AAC, PVC Cable, XLPE Cable, Building Wire, Control Cable ect.
3. Is the quality of your products guaranteed?
Yes,the quality of our products is highly guaranteed. Our workshops are equipped with advanced machines and test equipment, and our workers are highly experienced and committed. We strictly follow the international standards and customers' requirements. The samples during production of your orders are available on demand. We will do the inhouse inspection for every batch of products. You can also send your inspection team to our site.
4. How can I get samples?
Please tell us the detailed information of products you need. Then we will check our stock. If we don't have the exact model you need, please consider whether the similar model is OK for you.
5.What is your waranty terms?
The waranty period of all of our products is one year after they arrived at the destination port. Disclaimer:the waranty terms don't cover the failures caused by violence handling,installation and operation.